| 1 | Name of Work: Muktakashi Manch mein Shochalay and Rangai Putai ka Karya.Note :-(1)- GST Excluded on the aforesaid work. |
| 2 | Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by Engineer-in-charge with in a distance of 60 mt. (200 feet). 692 SOR(2022) |
| 3 | Dismantling reinforcement cement concrete or reinforcement brick work, including stacking of materials as directed by Engineer-in-charge with in a distance of 60 mt. (200 feet). 694 SOR(2022) |
| 4 | Dismantling cement concrete or brick or granolithic S floors including base concrete and including stacking of dismantled materials as directed by Engineer-in-charge with in a distance of 60 mt. (200 feet). 697 SOR(2022) |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineerin charge.(hard rock) requiring Blasting 2.7.2 DSR(2023) |
| 6 | Earth work in Filling in ordinary soil, excavation to be in the form of regular pits not exceeding 1/2 metre (20\\") in depth and earthwork in embankment to be in 20 cm(8\\") layers, including ramming & dressing the surface to required levels and slopes and also including 1.5 metre (5fts) lifts and 30 m. (100') lead. The earth from cutting to be used in making filling or to be deposited as spoil banks within 30 metres (100 fts) distance as directed by Engineer-in- charge.(5Km) 253 SOR(2022) |
| 7 | Cement concrete with 4 cm (1.5\\") gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T & P etc. required for proper completion of the work 281 SOR(2022) |
| 8 | Cement concrete with 4 cm (1.5\\") gauge approved stone ballast, approved coarse sand and cement in the proportion of 4:2:1 including supply of all materials, labour and T & P etc. required for proper completion of the work 279 SOR(2022) |
| 9 | RCC work with cement approved coarse sand and 2 cm (314) gauge approved stone ballast in the proportion of 1:1.5.3 in Sintals of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G. binding wire and including necessary contering and shuttering etc and also including supply of all materials, labour& T&P etc required for proper completion of the work indong wire cost being inclucted in the item.As item 283[1] above but in R.C.C at foundation and Footing with 4 cm. (1.5\\") gauge approved stone ballast 287(1) SOR(2022) |
| 10 | RCC work with cement approved coarse sand and 2 cm (314) gauge approved stone ballast in the proportion of 1:1.5.3 in lintals of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G. binding wire and including necessary contering and shuttering etc and also including supply of all materials, labour& T&P etc required for proper completion of the work indong wire cost being inclucted in the item.As in item 283(1) above but in the lighter beams, i.e. having spans above 6 m. (20') 285(1) SOR(2022) |
| 11 | RCC work with cement approved coarse sand and 2 cm (314) gauge approved stone ballast in the proportion of 1:1.5.3 in Sintals of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G. binding wire and including necessary contering and shuttering etc and also including supply of all materials, labour& T&P etc required for proper completion of the work indong wire cost being inclucted in the item.As in item 283(1) above but in R.C.C T beam and slab roofs and R.C.C columns 288(1) SOR(2022) |
| 12 | RCC work with cement approved coarse sand and 2 cm (314) gauge approved stone ballast in the proportion of 1:1.5.3 in lintals of doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G. binding wire and including necessary contering and shuttering etc and also including supply of all materials, labour& T&P etc required for proper completion of the work indong wire cost being inclucted in the item.An dem No. 283(1) above but for slab 284(1) SOR(2022) |
| 13 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & overlapping & hooks. 504 SOR(2022) |
| 14 | Providing and applying Plaster of Paris Putty of 2 mm Thickness over plastered surface to prepare the surface even and smooth complete. Ref DAR 13.26 SOR(2022) |
| 15 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 13.41.1 DSR(2023) |
| 16 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 13.50.3 DSR(2023) |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 13.62.1 DSR(2023) |
| 18 | Painting or Varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should confirm to the I.S.I.No. 103 1950 641 SOR(2022) |
| 19 | First class brick work in 1:6 cement and fine sand of 1.25 FM. mortar in foundation and plinth including supply of all materials, labour and T & Petc. required for proper completion of the work. 303 SOR(2022) |
| 20 | First class brick work in 1:4 cement and fine sand of 1.25 FM. mortar in foundation and plinth & super- structure including supply of all materials, labour and T & Petc. required for proper completion of the work. 305+309+310 SOR(2022) |
| 21 | 12 mm Cement plaster in single coat on fair side of single or half brick wall for interior plastering upto floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80 mm. In girth and finished even and smooth. No extra for mixing any additive.(II) 1 Cement: 4 fine sand 17.58 SOR(2022) |
| 22 | 15 mm Cement plaster in single coat on rough side of single or half brick wall for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80 mm. In girth and finished even and smooth.(II) 1 Cement: 4 fine sand 17.59 SOR(2022) |
| 23 | Supply and fixing 5 mm thick China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labour and tools etc, required for completion of the work. (size of tiles upto 200 x 300 mm) 628 SOR(2022) |
| 24 | Providing and laying of 80mm Interlocking concrete block pavement laid in stone dust base and fill joint with fine sand. Joint filled after labling and dressing base including supply of all material, labour, T&P etc required for proper completion of the work. NEW item No-3 SOR(2022) |
| 25 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)Red sand stone - exposed face fine dressed with rough backing.(30mm Thick) 8.14.1.5 DSR(2022) |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20 mm nominal dia Pipes 18.7.2 DSR(2023) |
| 27 | C.P Stop cock heavy quality (Gem Mikadeo/Encess's williams or eqv.) 48 SOR(2022) |
| 28 | C.P bib cock heavy quality (Gem Mikadeo/Encess's williams or eqv.) 44 SOR(2022) |
| 29 | Bakelite seat covers for commode ESSLO make white. 9 SOR(2022) |
| 30 | Stone work (machine cut edges in veneer work) for wall lining upto 10 m height, backing filled with a grout of 12 mm thick cement mortar 1:3 (1 Cement : 3 coarse sand) and jointed with Cement mortar 1:2 (1 cement : 2 stone dust), including grinding with hand grinder on joints, rubbing and polishing complete. (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately).Prepolished kota stone slabs on exposed face25 mm thick 8.18.1.1 DSR(2023) |
| 31 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats,weather silicone sealant, backer rods etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with luminium composite panel cladding, cleaning and protection of the curtain wall with aluminium omposite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 8.32 DSR(2023) |
| 32 | 30 mm Telescopic flushing pipe PVC for W.C. with bras union 7 SOR(2022) |
| 33 | White glazed earthen ware (European Type) W.C, Pan 580 mm dia 4 SOR(2022) |
| 34 | Flat back or angular front lipper urinal basin of white glazed earthen ware 465x355x265 mm 10 SOR(2022) |
| 35 | Wash hand basin 550x400 mm size of white glazed earthen ware ( 22 \\"x16\\") 12 SOR(2022) |
| 36 | Mirror of Atul make with Indian polish of 600x450 mm dia size with beveled edge 22 SOR(2022) |
| 37 | C.P. Brass towel rail 750x20mm together with pair of C.P. brass brackets to fit the towel rail. 25 SOR(2022) |
| 38 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 17.18.1 DSR(2023) |
| 39 | Supply and installing of low density polyethylene seamless one peace moulded tank and placing the same in proper position including all taxes labour and T&P etc for proper completion of the work. Tank should be ISI marked (for 1000 Liters) Ch-19 New item no-1 SOR(2022) |
| 40 | Mild steel or iron work in havy sizes such as trusses: builts up gates, door frames, record racks roof work. glites etc. wrought to required form including drilling holes; rivetting or welding where necessary, and also including supply of steel, bolts, nuts etc.& their fixing required for proper completion of the work. 503 SOR(2022) |
| 41 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade 8.10.2 DSR(2023) |
| 42 | S/F Dustbin including lab mat etc all MR |
| 43 | Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge. 26.25 DSR(2023) |
| 44 | Supply and fixing of 100 mm dia PVC down pipe complete with rose heads bends M.S Clamps 2.5 cm x 3 mm fixed to walls by 15 cm Long 6 mm dia nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools and plant etc required for proper completion of work. Ch-19 New item no-3 SOR(2022) |
| 45 | ELECTRIC WORK Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10 Group C 1.10.3 |
| 46 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.142 X2.5 sq. mm + 1X2.5 sq. mm earth wire 1.14.2 |
| 47 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1.14.3 |
| 48 | 2x 6Sq.mm +1x6 Sq.mm earth wire 1.7.4 |
| 49 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24 5/6 A switch 1.24.1 |
| 50 | 15/16 A switch 1.24.3 |
| 51 | 3 pin 5/6 A socket outlet 1.24.4 |
| 52 | 6 pin 15/16 A socket outlet 1.24.5 |
| 53 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 1.26 |
| 54 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 1.276 Module (200mmX75mm) 1.27.4 |
| 55 | 8 Module (125mmX125mm) 1.27.5 |
| 56 | Supplying and fixing Following modular base & Cover plate on existing modular metal boxes etc. as required. 1.286 Module 1.28.4 |
| 57 | 8 Module 1.28.5 |
| 58 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50Up to 450 mm sweep 1.50.1 |
| 59 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1.51 |
| 60 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. 1.58 |
| 61 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10Single pole 2.10.1 |
| 62 | Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS. 1.38-10 watt 1.3.2 |
| 63 | Supply of AC 200mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Light Duty) with blades,cover etc. complete as required. MR Please Enable Macros to View BoQ information |