| 1 | Hanging power fence |
| 2 | P.P Reel insulator , Must be of virgin plastic metirial. Polypropylene or equivalent with break down voltage of 15 KV(weight 25gm avg, length 4.6 cm avg) |
| 3 | Strain insulator, Must of poly polypropylene plastic rated for 15 KV UV stabillized ,(weight 40 gm avg, length 7 cm avg) |
| 4 | GI post 12 feet , 2\\" GI pipe, 14 guage Thickness,total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6 mm at end of bend pipe |
| 5 | Intermediate post (T angle post) , 6ft., painted(25mm*25mm*3mm)having holes of size 6 mm at required interval of fencing installation |
| 6 | Supporting post, 10ft.,GI-1,14 guage Thickness,painted |
| 7 | Stay (t angle), 2ft., painted(25mm*25mm*3mm) |
| 8 | 12 swg HT wire, 12 guage,2.5 mm dia High tensile wire with zinc coating for use as conducting wires,binding strain insulator |
| 9 | 14 swg Binding wire , high quality zinc coating wire for binding reel insulator, tighing support post with corner post |
| 10 | 1.5 mm stainless steel wire rop 304 grade |
| 11 | Aluminium ferruel, aluminium ferruel 3 mm |
| 12 | Wire tightner , Permanat wire tightner made of special Aluminium alloy designed for KV, UV stabillized |
| 13 | Earth rod, Copper plated earth rod 14 mm -3ft. Length |
| 14 | Earthing compound, Earthing compound 8 kg |
| 15 | Gate handle, Gate handle and spring assembly, Handle made of polyethylene |
| 16 | Leadout cable,Leadout cable for fence system double insulated GI cable inner core wire 2 sq.mm.hot dipped galvanised steel core, capaie of with standing 15KV should be provided to prevent bimetal salt formation at connections |
| 17 | Single core 2.5 mm sq. cable, 2.5 mm2 single core copper cable for connecting the solar panel to the tubular battery through charge control unit with required terminal sockets,nut and bolt,washer |
| 18 | Lightning diverter, 15kv -50kv rod gap arrester,must be capable of diverting stray lightning and adjustable for spark gaps adequate earthing to be provided |
| 19 | 100 watt solar panel, 100 watt/12 volt and above poly cristalline with 10 year warranty having IEC/MNRE certification |
| 20 | Charge control unit, 20 A,12/24 PWM charge controller unit of standard make suitable to control the charging of the tubular battery |
| 21 | Energizer, energizer with 10 KV Output Safety Standards to be followed are BIS 302-2-76 IEC60335-2-76. Switch-high, medium and low power setting. |
| 22 | Fence alarm system, Fence alarm system covering area of 1.5 KM |
| 23 | Solar panel sapporting stand with metal box painted (for battery and energiser), 18 guage thickness metal box(lockable). GI-Sheet, painted should be capable of housing battery, charge controller and energizer and fixed with reguired clamps and nut and bolt on solar panel suppoert stand made of GI pipe of 50mm diamere and B class type with suitable arreangement for holding the panel |
| 24 | Warning sign, Polyethylene plastic with satuatory wrning with signs |
| 25 | Tubular battery 12v , 100AH, 12 v, 100 AH C10 rating with full 5 year replacement warranty (tower battery) for energising the energiser Please Enable Macros to View BoQ information |