| 1 | AMC charges for 250KVA D.G. Set Part No.MNL.DEC.01.0.00 for 250KVA D.G. for 1year, 4visits and unlimited breakdown calls complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 2 | Dehydration of 630/1000KVA Transformer main tank oil complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 3 | ON/OFF operation of chillar Air conditioning system as per requirement of HSVP and day to day over hauling of air conditioners and operation of air conditioners complete in all respect up to the entire satisfaction of Engineer-in-charge. (Rate without GST). |
| 4 | Operation of H.T. Panels, L.T. Panels, VCB, ACB, and ON/OFF operation of all type of equipments installed like light fixtures, Fans, UPS, Projector, etc. and attending the day to day fault complaints complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 5 | Overall maintenance of chillar type Air Conditioning system including servicing with complete material and labour charges i.e. repairing or replacement of defective parts of machines, maintaining the thermal installation proper, servicing of all parts of chillar Air conditioning system including repairing or replacement of defective parts of machinery installed i.e. CHW end System Type Pump, CDW End Suction Type Pump, FRP inducted Draft Cooling Tower with Ms pipes, AHU, various types of Valves, Thermometers and Pressure Gauge, Expansion Tank, Drain Piping, Air Vents, Duct Work, Duct Acoustic, Plant Room, Acoustic Lining, Grills/Diffusers/Louvers, Air Diffuser, Valve Control Dampers, AC Control Panel, Control Panel of AHU, Electrical cables, Earthings complete in all respect and maintaining the system in working conditionfor 365 Days X 24 Hours. (Rate without GST). |
| 6 | Removing oil leakage from the 1000 KVA transformer including all allied material and labor charge complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 7 | Servicing charges for 2000A ACB complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 8 | Servicing charges for 630A VCB complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 9 | Servicing charges for 800A-1600A ACB complete in all respect up to the entire satisfaction of the Engineer-incharge. (Rate without GST) |
| 10 | Supply and erection 1.0 sq mm 3 core copper flexible wire PVC insulated and sheathed, 1100 volt grade confirming to IS 694 complete with necessary connections complete in all respect upto the Entire satisfaction of Engineer-In-Charge. Make –Havell’s/KEI/RR/Polycab (Rate without GST). |
| 11 | Supply and Erection of 1.5 sq mm single core copper wire multi stand ISI marked, FRLS PVC insulated complete with necessary connections complete in all respect up to entire satisfaction of engineer-in-charge of work. (Rate without GST). |
| 12 | Supply and Erection of 10.0 sq mm single core copper wire multi stand ISI marked, FRLS PVC insulated complete with necessary connections complete in all respect up to entire satisfaction of engineer-in-charge of work. (Rate without GST). |
| 13 | Supply and Erection of 15Amp combined Box complete in all respect upto the entire satisfaction of Engineer-incharge. (Rate Without GST) |
| 14 | Supply and Erection of 2.5 sq mm single core copper wire multi stand ISI marked, FRLS PVC insulated complete with necessary connections complete in all respect up to entire satisfaction of engineer-in-charge of work. (Rate without GST). |
| 15 | Supply and Erection of 4.0 sq mm single core copper wire multi stand ISI marked, FRLS PVC insulated complete with necessary connections complete in all respect up to entire satisfaction of engineer-in-charge of work. (Rate without GST). |
| 16 | Supply and erection of outgoing VCB rack in rack out garari for 11 KV, 630A, VCB make CG complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 17 | Supply and filling of Transformer oil complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 18 | Supply and Replacement of AIR CLEANER PRIMARY ELEMENT of Part No.KV2.505.02.0.00 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 19 | Supply and Replacement of AIR CLEANER SAFETY ELEMENT of Part No.KV2.505.03.0.00 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 20 | Supply and Replacement of FUEL FILTER ELEMENT of Part No.48.117.04.0.00 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 21 | Supply and Replacement of FUEL FILTER ELEMENT of Part No.48.117.05.0.00 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 22 | Supply and Replacement of Kirloskar Care Premium Genuine 20 Liter Oil Can of Part No. 82.060.10.0.20 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 23 | Supply and Replacement of Kirloskar Care Premium Genuine 5 Liter Oil Can of Part No. 82.060.10.0.05 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 24 | Supply and Replacement of SPIN ON LUBE OIL FILTER of Part No. 06.436.01.0.00 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 25 | Supply and Replacement of V-BELT (AVX 13 X 1015L) of Part No.F6.019.16.0.00 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 26 | Supply and Replacement of V-BELT (AVX 13 X 1562L) of Part No.F6.019.16.0.00 for 250KVA D.G. Set complete in all respect up to the entire satisfaction of the Engineer-in-charge. (Rate without GST) |
| 27 | Supply of C-Power maintenance kit (require for servicing of ACBs as recommended by OEM LandT) complete in all respect up to the entire satisfaction of the Engineer-incharge.(Rate without GST) |
| 28 | Supply, erection, testing and commissioning of 20watt LED light fixture batten type complete with necessary connections complete in all respect up to the Entire satisfaction of Engineer-In-Charge. (Rate without GST) |
| 29 | Supply, erection, testing and commissioning of Exhaust fan 300mm (12 inch) with bearing complete with necessary connections complete in all respect up to the Entire satisfaction of Engineer-In-Charge. (Rate without GST) |
| 30 | [13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 31 | [13.32]Providing and fixing bolts including nuts and washers complete. |
| 32 | [23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA |
| 33 | [23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA |
| 34 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA |
| 35 | [23.22.1.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.7. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 400 Amp, 50 KA |
| 36 | [23.22.1.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.8. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 600 to 800 Amp, 50 KA |
| 37 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 38 | [23.22.5.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole |
| 39 | [23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE |
| 40 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE |
| 41 | [23.8.11.1] FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch |
| 42 | [23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch |
| 43 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket |
| 44 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket |
| 45 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt |
| 46 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) |
| 47 | [24.3.3.2]HT CABLE 3.2. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 to 185 sqmm |
| 48 | [24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm |
| 49 | [24.3.5.3]HT CABLE 5.3. Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 185 to 240 sqmm Please Enable Macros to View BoQ information |