| 1 | Replacement of old AC at Judges chamber No.8C |
| 2 | OD276907/2025-2026:Supply, Installation, Testing and Commissioning of wall mounting split air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R32/410A eco friendly refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with insulation, control cable up to 3-5m, 3 m drain pipe, Copper Condenser, stand, microprocessor control with cordless remote control etc. PCB should have minimum 5 year warranty and 10 year warranty on compressor(warranty card are to be provided).Minimum 2 Nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 2/2.2TR (3 Star& above) Inverter A.C unit, ( Daikin / carrier/Toshiba/Mitsubishi) |
| 3 | OD276905/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe betweenout door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mmthick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge |
| 4 | OD276906/2025-2026: Supply and installation of rigid PVC Drain piping with 9mm nitrile rubber tubular insulation, complete fittings, U trap as specified nearest drain point |
| 5 | 90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm |
| 6 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 7 | OD276903/2025-2026: Supply, Conveyance & Installation of Voltage stabilizer suitable for split type 2 TR AC unit, capacity 15A with voltage range of 175-275V and out put range of 210 - 240V (V Guard VG500) or its equivalent.* |
| 8 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 9 | OD348940/2025-2026:Charges for dismantling the existing split AC Units, Copper tubes etc, complete, making good the damages of walls and conveying the dismantled materials to section store. |
| 10 | OD349097/2025-2026:Supply & renewal of inverter PCB for Out door unit of 2 TR split AC |
| 11 | OD349145/2025-2026:Supply & renewal of inverter PCB for In door unit of 2 TR split AC Please Enable Macros to View BoQ information |