| 1 | Dismantling tile work in floors/dado and roofs laid in cement mortar including stacking material within 100 m lead For thickness of tiles above 10 mm and up to 25 mm |
| 2 | Dismantling tile work in floors/dado and roofs laid in cement mortar including stacking material within 100 m lead For thickness of tilesabove 25 mm and up to 40 mm |
| 3 | Dismantling plain cement concrete manually / by mechanical means carefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-incharge |
| 4 | Dismantling steel work in single sections including dismantling and stacking within 100 m lead In R.S Joists, Angles etc. |
| 5 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismantling and stacking within 100 m lead |
| 6 | Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge |
| 7 | Dismantling doors, windows and clear storey openings (steel / wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100 m lead (full windows) Of area 3.00 Sq.M and below |
| 8 | Dismantling old plaster / skirting carefully , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 100 m lead |
| 9 | Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and dispoal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge |
| 10 | Providing SFMC Micro concrete for strengthening of structural members including mixing, pouring, curing as per manufacturer specifications and as directed by the Engineer-in-charge |
| 11 | Using 100% SFMC |
| 12 | Using SFMC with 50% Quartz aggregate by weight (Only SFMC consumed alone will be measured for payment) |
| 13 | Providing and applying High polymer modified,grey cement-based tile adhesive suitable for fixing tile/stone in interior walls/floor and exterior floor situations upto 6mm bed thickness (can be extended up to 12 mm in area of limited extent). The set adhesive is water-resistant and is suitable for use in showers and totally immersed situations such as swimming pools. It conforms to IS 15477: 2019 Type 2T and EN 12004: 2017 (C2T/C1T) standards completed as directed by the Engineer-in-charge. |
| 14 | Providing and fixing Minimum 15-17 mm thick gang saw cut mirror polished Granite, machine cut Granite (Moon white shade or approved shade) for flooring /skirting in lobby, staircase including (Tread and Riser), kitchen platforms, vanity counters, window sills, facias and similar locations of required size, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand and white cement in mortar) with joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing and polishing the edge to give high gloss finish etc. complete as directed by the Engineer-in-charge at all levels. |
| 15 | Extra for providing edge moulding to Minimum 15-17 mm thick Granite slab counters, trade, vanities etc. including machine polishing to edge to give high gloss finish etc. Complete as per design approved by Engineer-in-charge. |
| 16 | Providing and fixing Minimum 15-17 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Jet Black colour for flooring, staircase, staircase landing, kitchen platforms, vanitiy counters, wash basin counters, door frames, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete at all levels. |
| 17 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved make. shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of approved make of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. |
| 18 | Providing Structural steel work using angles, channels, joists and other sections, welded and / or bolted in built up sections for trusses , structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge |
| 19 | Up to and including 300 mm Joists, 350 mm channels, and below sections using materials of approved manufacturers. (ISI marked). All test reports to be provided along with the supply of the materials. Note: 1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2) Welding weights, connections, bolts and nuts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. 3) All holes will be made by drilling only. Gas cutting of holes will not be permitted. 4) Welding Electrodes confirming to IS 814 shall be used. |
| 20 | Providing and fixing various sections using 304 grade Stainless Steel pipes/sections of approved size and make and quality by welding, mirror / matt polishing, fixing at site, all consumables, etc. for balcony railing, staircases railing, nosing, brackets of glass facade/curtainwall as per drawings, specifications. complete as directed by the Engineer-in-charge.Note: 1) Steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2) Welding weights, connections, bolts and nuts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. 3) All holes will be made by drilling only. Gas cutting of holes will not be permitted. 4) Welding Electrodes confirming to IS 814 shall be used. |
| 21 | Providing REINFORCEMENT FOR REINFORCED CEMENT CONCRETE at all levels including supplying, preparation of bar bending schedules,cutting, bending, transporting, fixing, tieing in position with 1.6 mm dia soft drawn annealed binding wire all labour charges, cost of cover blocks in specified grade of concrete etc. complete including cost of binding wire as per specifications and drawings. Steel Supplied by the Contractor. Using TMT bars of specified grade all dia bars to be supplied by the contractor manufactured confirming to IS:1786. |
| 22 | Providing , centering ,shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels. |
| 23 | For Super Structure |
| 24 | Providing and constructing brick work in cement mortar using Standard bricks of approved quality / class, make / brand in super structure above plinth up to Floor-II level in all shapes and sizes including curing, raking out joints complete as per specifications and as directed by the Engineer-in-charge. Brickwork in super structure with standard bricks in C.M 1:4 using crushed Sand |
| 25 | Providing and constructing brick work in cement mortar C.M 1:4 using Standard bricks of approved quality / class, make / brand and using crushed Sand in super structure above floor II level and up to and including 20 m height by lifting material, in all shapes and sizes including curing, raking out joints complete as per specifications and as directed by the Engineer-in-charge. Please Enable Macros to View BoQ information |
| 26 | Providing and constructing brick work in cement mortar C.M 1:4 using Standard bricks of approved quality / class, make / brand and using crushed Sand in super structure above floor II level and up to and including 20 m height by lifting material, in all shapes and sizes including curing, raking out joints complete as per specifications and as directed by the Engineer-in-charge. Please Enable Macros to View BoQ information |