| 1 | Lab cupboad works in school of environmental studies |
| 2 | 21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 3 | 21.1.2.1 For shutters of doors, windows & ventilators including providing and fixinghinges / pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Anodised aluminium ( anodised transparent or dyed to required shadeaccording to IS : 1868, Minimum anodic coating of grade AC 15) |
| 4 | 50.12.2.5 Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick asapproved by the Engineer in charge and should be supplied in a single length of 12 Mor as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch inhorizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses,and including cutting to size and shapes where ever required. |
| 5 | 9.114.1 Providing and fixing magnetic catcher of approved quality in cupboard/ward robeshutters, including fixing with necessary screws etc. complete.Triple strip verticaltype |
| 6 | 21.16.3Providing and fixing aluminium round shape handle of outer dia 100 mm with SSscrews etc. complete as per direction of Engineer-in-Charge.Polyester powder coatedminimum thickness 50 micron aluminium |
| 7 | 21.13Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 8 | Partition of lab |
| 9 | 21.1.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shadeaccording to IS : 1868, Minimum anodic coating of grade AC 15) |
| 10 | 21.1.2.1 For shutters of doors, windows & ventilators including providing and fixinghinges / pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Anodised aluminium ( anodised transparent or dyed to required shadeaccording to IS : 1868, Minimum anodic coating of grade AC 15) |
| 11 | 50.12.2.5 Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick asapproved by the Engineer in charge and should be supplied in a single length of 12 Mor as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch inhorizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses,and including cutting to size and shapes where ever required. |
| 12 | 21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 13 | 21.4.1 Providing and fixing double action hydraulic floor spring of approved brand andmanufacture conforming to IS: 6315, having brand logo embossed on the body / platewith double spring mechanism and door weight upto 125 kg, for doors including costof cutting floors, embeding in floors as required and making good the same matchingto the existing floor finishing and cover plates with brass pivot and single piece M.S.sheet outer box with slide plate etc. complete as per the direction of Engineer -inCharge.With stainless steel cover plate minimum 1.25 mm thickness |
| 14 | 21.13 Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 15 | 21.16.3 Providing and fixing aluminium round shape handle of outer dia 100 mm with SSscrews etc. complete as per direction of Engineer-in-Charge.Polyester powder coatedminimum thickness 50 micron aluminium Please Enable Macros to View BoQ information |