| 1 | B/R PORTIONDemolition of unreinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 2 | Dismantling structural steel work inluding doors, gates but excluding framed truss etc complete all as specified and directed. |
| 3 | Material & Labour for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 4 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 5 | M&L for plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggreagate) for fixing rails of gates complete all as specified and directed. |
| 6 | M&L for prepration of new or previously untreated steel Surfaces of any description, over 10cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 7 | M & L for complete removal of existing treatment of old surfaces of walls and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 8 | M&L for 18-20mm thick Granite stone ( any type, any colour) work (table rubbed and polished) in vertical surfaces such as dado , skiting etc including 10mm thick backing coat in CM (1:4) including admixture of pigment to match with shade of granite complete all as specified and directed. |
| 9 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in any type of soil complete all as specified and directed. |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kinds of soil complete all as specified and directed. |
| 11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m complete all as specified and directed. |
| 12 | Excavating trenches by mechinical / manual means of required width for pipes, cables, exceeding 80mm dia but not exceeding 300mm dia including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 13 | M&L for providing and laying in position plain cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) complete all as specified and directed. |
| 14 | M&L for plinth protection 50mm thick of plain cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete all as specified and directed. |
| 15 | M&L for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification complete all as specified and directed. |
| 16 | M&L for plain cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete complete all as specified and directed. |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts complete all as specified and directed. |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers complete all as specified and directed. |
| 20 | M&L for ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum complete all as specified and directed. |
| 21 | M&L for ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum complete all as specified and directed. |
| 22 | M&L for Steel reinforcement using TMT bars, Gde Fe-500D for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level complete all as specified and directed. |
| 23 | M&L for steel reinforcement using TMT bars Gde Fe-500D for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level complete all as specified and directed. |
| 24 | M&L for brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With Modular bricks complete all as specified and directed. |
| 25 | M&L for half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in CM 1:4 superstructure above plinth level up to floor V level complete all as specified and directed. |
| 26 | M&L for 1st quality ceramic glazed wall tiles 7.0 to 8.0mm thick conforming to IS: 15622 of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 27 | S&F factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification complete all as specified and directed. |
| 28 | S&F factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded orsealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications complete all as specified and directed. Non decorative finish. |
| 29 | S&F aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete all as specified and directed : 300x16 mm |
| 30 | S&F aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 31 | S&F aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 150x10 mm complete all as specified and directed. |
| 32 | S&F ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete 100x58x1.90 mm complete all as specified and directed. |
| 33 | M&L for plain cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete all as specified and directed. |
| 34 | S&F Vitrified Antiskid floor tiles of size 600 x 600mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and directed. |
| 35 | S&F for Polished Granite stone flooring colour black or equivalant, in required design and patterns, in linear as well as curvilinear portions of the building complete with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. complete all as specified and directed. |
| 36 | M&L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 37 | M&L for White washing with lime to give an even shade :White washing with lime to give an even shade : New work (three or more coats) complete all as specified and directed. |
| 38 | M&L for Cement plaster (IN COARSE SAND) :15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) complete all as specified and directed. |
| 39 | M&L FOR CEMENT PLASTER (IN COARSE SAND) :15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) complete all as specified and directed. |
| 40 | M&L for 500 x 500 x 40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade for compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick river sand, including spreading, well ramming, consolidating and finishing smooth etccomplete all as specified and directed. |
| 41 | M&L for white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required complete all as specified and directed. |
| 42 | M&L for wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require complete all as specified and directed. |
| 43 | M&L for 100 mm sand cast Iron grating for gully trap, including connecting to trap/ manhole using PVC (SWR)/ cast iron pipe and fittings complete all as specified and directed. |
| 44 | M&L for 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and directed. |
| 45 | M&L for PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 46 | Supply, laying and fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes complete all as specified and directed. |
| 47 | Supply, laying and fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes complete all as specified and directed. |
| 48 | Supply and fixing C.P. brass bib cock of 15mm nominal bore approved quality conforming to IS:8931 complete all as specified and directed. |
| 49 | Supply and fixing C.P. brass stop cock (concealed) of 15mm nominal bore standard design and of approved make conforming to IS:8931 complete all as specified and directed. |
| 50 | Supply and fixing PTMT grating of approved quality and colour. Circular type: 125 mm nominal dia with 25 mm waste hole complete all as specified and directed. |
| 51 | Supply and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore complete all as specified and directed. |
| 52 | Supply and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. pressure, with plastic floats complete : 25 mm nominal bore, 152mm long, weighing not less than 440 gms complete all as specified and directed. |
| 53 | Supply and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore complete all as specified and directed. |
| 54 | Supply and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms complete all as specified and directed. |
| 55 | Supply and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed. |
| 56 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 57 | S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares in n.exc 0.5 sq.m in each pane complete all as specified and directed. |
| 58 | Supply laying and jointing glazed stoneware pipes of dia 200mm class SP-1 with stiff mixture of cement mortar in the Proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete all as specified and directed. |
| 59 | Supply and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.G pipes including bed concrete as per standard design complete all as specified and directed. |
| 60 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared complete all as specified and directed. |
| 61 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, complete all as specified and directed :All kinds of soil |
| 62 | M&L for Hardcore of gauge n exc. 63mm, deposited, spread andlevelled in layers n exc.15cm thick, watered andrammed to a true surface complete all as specified and directed. |
| 63 | M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) complete all as specified and directed. |
| 64 | Providing and laying factory made chamfered edge rubber moulded Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60 mm thick C.C. paver block of M-35 grade with approved colour design and pattern complete all as specified and directed. |
| 65 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone complete all as specified and directed. |
| 66 | M&L for painting over kerb stone Surfaces of any description over 10cm girth or width, not otherwise described complete all as specified and directed. |
| 67 | E/M PORTIONSupply & fixing, testing and commissioning of single phase sliding gate motor with accurator and starting button having gate weight capacity of 2500 kg with all connected accessories complete all as specified and directed. |
| 68 | Supply only trolley with rack suitable for movement of along the track controlled by pinnion directely couple with motor complete all as specified and directed. |
| 69 | Supply only bearing mounted 100mm dia of 50mm thick wheels alongwith mounting plate complete all as spectified and as directed. |
| 70 | Supply only bearing mounted nylon rolled 50mm dia 100 mm height along with mounting plate complete all as specified and as directed. |
| 71 | Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed. |
| 72 | Supply and fix MCB SPN 240 Volts 6-32 Amp breaking capacity 10 KA rating complete all as specified and directed. |
| 73 | Supply and fix in repair sheet metal enclosure MCB SPN DB 04 Way double door 240 Volt complete all as specified and directed. |
| 74 | M& L Sub Main Wiring two run of size 6 Sqmm PVC insulated electric power cable(heavy duty) 1100 Volt Grade FRLSH with stranded copper conductor with 6.0 Sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (two run of 6 Sqmm cable and one of 6.00 Sqmm wire and one run of PVC conduit/Casing Caping will be measured as one unit) including taking down of existing unserviceable submain wiring complete all as specified and as directed. |
| 75 | S&F wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit concealed type, with piano type switch, phenolic laminated sheet, suitable size M.S. box & earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required complete all as specified and directed. |
| 76 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 77 | Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 78 | S&F 10 w 2ft LED type mirror light fitting complete all as specified and directed. |
| 79 | S&F 25 w LED type building security light fitting complete all as specified and directed. |
| 80 | Supply, laying & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core through conduit with fixing complete all as specified and directed. |
| 81 | S&F MCB DB 240 V SPN 4 way on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolators) |
| 82 | S&F 3 pin 5A ceiling rose on existing junction box / wooden block /wall including connections etc complete all as specified and directed. Please Enable Macros to View BoQ information |