|
| 1 | LAN in work stations in sections at High Court of Kerala |
| 2 | OD296948/2025-2026:Supply and installation of 48port Access Switch with minimum 48x GE RJ45 and 4x 10GE SFP+ ports. Switching throughput - 176 Gbps, Forwarding Capacity - 262 Mpps, 32K MAC Address, IPv4 and IPv6 static routing. RIPv1/v2, RIPng, OSPFv2/v3 Should support IEEE 802.3ad Link Aggregation with LACP,Link Aggregation Group Size 8, Should support virtual wire between two ports for troubleshooting,should support Static L3 hardware-based routing ,Switch should support IP conflict detection and notification,should support LLDP, should support Storm Control, LoopGuard,LLDP-MED, MCLAG(Multi-chassis link aggregation.Switch should support Device Detection to understand the type of device operating systems, display the IP address.,Should support centralized security management, configuration and reporting through a single console from existing switch controller or from external NMS RIPv1/v2, RIPng, OSPFv2/v3, Certification FCC, CE, RCM, VCCI, BSMI, UL, CB, RoHS2. Maf to be attached.Preferred Make : Juniper,HP,Fortinet |
| 3 | OD292572/2025-2026:Supply and installation of 24 port Access Switch with minimum 24x GE RJ45 and 4x 10GE SFP+ ports. Switching throughput - 128 Gbps, Forwarding Capacity - 190 Mpps, 16K MAC Address, 1GB DDR4,256MB flash,redundant AC power supply,IPv4 and IPv6 static routing. RIPv1/v2, RIPng, OSPFv2/v3 Should support IEEE 802.3ad Link Aggregation with LACP,Link Aggregation Group Size 8, Should support virtual wire between two ports for troubleshooting,should support Static L3 hardware-based routing ,Switch should support IP conflict detection and notification,should support LLDP, should support Storm Control, LoopGuard,LLDP-MED, MCLAG(Multi-chassis link aggregation.Switch should support Device Detection to understand the type of device operating systems, display the IP address.,Should support centralized security management, configuration and reporting through a single console from existing switch controller or from external NMS RIPv1/v2, RIPng, OSPFv2/v3, Certification FCC, CE, RCM, VCCI, BSMI, UL, CB, RoHS2. MAF to be attached Preferred Make : Juniper,HP,Fortinet |
| 4 | OD292576/2025-2026: Supply and installation of UL listed ETL 4 channel verified 1U rack mountable 24 port CAT-6 fully loaded patch panel with individually removable RJ45 &RJ11 compatible jacks.contact plating:1.27micrometers Au/Ni rear cable organizer,pannel should be made of cold rolled steel,powder coated ,front labelling facility required .operating life: Min.750 insetion cycles,Durability:Min. 200reterminations,dust covers to protects from dust&contaminants ,Material: Black powder coated CRS.Thickness :Min.1.52mm,front &rear port labelling as well as panel identification label-RoHS compliant including termination charges. Preferred Make: Actassi, Belden, Molex, Panduit, R and M, Commscope |
| 5 | OD292574/2025-2026: Supply, Installation, Testing and Commissioning of 24 Port fully loaded 1U Rack mountable LIU(Swing Type)with Splice tray ,pigtails and cable management. Preferred Make: Belden, ,Molex, R and M, Commscope |
| 6 | OD299062/2025-2026:Supply, installation , Testing and commissioning of 12 Port fully loaded 1U Rack mountable LIU with Splice tray ,pigtails and cable management. Preferred Make: Belden, ,Molex, R and M, Commscope |
| 7 | OD292579/2025-2026:Supply ,termination ,testing and commissioning of UL listed ETL 4 channel verified Information Outlet with CAT-6 keystone jack with dust protection,suitable for 22-24AWG bare copper conductor,contact plating: 5micron gold/Nickel as per TIA/EIA 568-B colour code confirming to the standards ANSI/TIA-568.2D,ISO/IEC 11801,IEEE 802.3,ISO/IEC 60332,UL94V-0 rated or equivalent,Min. 500 insertion cycles and 100 reterminations and RoHS compliant. Preferred make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope |
| 8 | OD298546/2025-2026:Supply, fixing, testing certification and documentation of spring shutter front access single ABSFaceplate withRJ 45 Module .(Delta Certified) Preferred Make:Molex/ Legrand / Actassi / Belden /R and M/ Commscope |
| 9 | OD292586/2025-2026:Supply ,termination ,testing and commissioning of UL listed ETL 4 channel verified 1 Mtr CAT-6 (LSZH) Giga UTP patch cord having LSZH jacket,24AWG bare copper conductor UTP 4pair both end factory crimped with modular male plugs with min.500 insertion cycles terminated as per TIA/EIA 568-B colour code confirming to the standards ANSI/TIA-568.2,ISO/IEC 11801,IEEE 802.3,ISO/IEC 60332-1 and RoHS compliant.Preferred make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope |
| 10 | OD299061/2025-2026:Supply and providing 2 Mtr CAT-6 (LSZH) Giga UTP patch cord.Preferred make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope |
| 11 | OD299060/2025-2026:Supply, laying, testing (OTDR), certification and documentation of Single mode 6 core armored OS2 type outdoor fiber cable ,unitube,single sheathed,corrugated steel tape ,UV stabilised,polyethelene outer anti-termite and anti rodent, water blocking, gelly filled cable through conduit. Prefered Make : Molex/ Finolex/Commscope |
| 12 | OD299059/2025-2026:Supply and Installation of Fiber SM patch cord with LC-SC connectors and 1 meter length. Approved Make: Molex/ Legrand / Actassi / Belden /R and M/ Commscope |
| 13 | OD299111/2025-2026:Supply and installation of 10 G base single mode Optical Transceiver SFP+ module with minimum reach of 10 KM, same OEM as switch. |
| 14 | OD292580/2025-2026:Supply and fixing of 19 inch 15U (600mmx 650mm) rack with covered wire manager, cooling fan(2Nos), 2XAC distribution box, with side open and all other accessories. Make:- Rittal/Valrack/Netrack |
| 15 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 16 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 17 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 18 | OD298545/2025-2026:Charges for floor/wall cutting ,plastering and finishing the surface after laying cables through conduit |
| 19 | OD298629/2025-2026:Charges for dismantling existing unwanted cables , Information Outlets and conduits in the proposed rooms |
| 20 | OD336854/2025-2026:Supplying and drawing of UTP 4 pair CAT 6 LAN cable with LSZH sheath and minimum 23AWG copper conductor in the existing surface/recessed steel/PVC conduit as required3 run of CablePreferred Make: Molex,Commscope,R and M,Panduit |
| 21 | OD336855/2025-2026:Supplying and drawing of UTP 4 pair CAT 6 LAN cable with LSZH sheath and minimum 23AWG copper conductor in the existing surface/recessed steel/PVC conduit as required2 run of CablePreferred Make: Molex, Commscope, R and M, Panduit |
| 22 | OD336856/2025-2026:Supplying and drawing of UTP 4 pair CAT 6 LAN cable with LSZH sheath and minimum 23 AWG copper conductor in the existing surface/recessed steel/PVC conduit as required1 run of CablePreferred Make: Molex, Commscope, R and M, Panduit |
| 23 | Telephone cabling |
| 24 | OD296946/2025-2026:Supply, installation and testing of 20 pair Telephone Junction Box with KRONE connecting modules in a suitable M.S enclosure with Powder Coated paint of approved colour and lock andkey arrangement on wall with suitable fixing arrangement and making necessary connections. Preffered Make: Krone |
| 25 | OD296947/2025-2026:Supply, installation, testing and commissioning of RJ 11 information outlet in good quality with shutter arrangement in front plate on recess/ surface metal/PVC mounting box .Preferred Make: Molex, Legrand |
| 26 | 1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 27 | Installation of temporary LAN and telephone cabling to occupy the shifted sections(G3,G1,IT admin cell,Digitization )in connection with the installation of work station/cubicles. |
| 28 | OD297109/2025-2026:Labour charges for temporary arrangement of network connection and telephone cabling to accomodate the shifted sections(G3,G1,IT admin cell,E Courts,Digitization )in connection with the installation of work station/cubicles. Please Enable Macros to View BoQ information |