| 1 | Construction Of Pathway Inside Colony |
| 2 | OD152859/2025-2026 Pumping or Bailing out water and removing slush etc by using pump set including cost of labor, oil hire charges of pump set, etc complete |
| 3 | 3.5.2 Excavation in Soil with Dozer with lead upto 100 m <br> Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. |
| 4 | 11.4.1.1 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br> I. P.C.C grade M 10 <br> (i) Nominal mix 1:3:6 |
| 5 | 11.4.2.1 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br>II. P.C.C grade M 15 <br> (i) Nominal mix (1:2.5:5) |
| 6 | 12.5.1.1 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 <br> For height upto 5 m <br> I. P.C.C grade M 15 <br> (i) Nominal mix (1:2.5:5) |
| 7 | 11.8 Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 8 | OD153066/2025-2026 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5m. All kind of soil |
| 9 | OD152884/2025-2026 Filling with Quarry muck - Filling up low lying and water logged areas with local meterial/quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc. complete for improving the CBR value of subgrade |
| 10 | 75.8.1 Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification(i) Nominal mix (1:2:4) |
| 11 | OD153018/2025-2026 Providing & amp fixing granite of any colour and shade for name board of required size laid over base of cement mortar 1:4 including all charges etc complete at all, levels, including lettering & fixing |
| 12 | Maintenance To House Inside Colony |
| 13 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 14 | 13.16.1 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 15 | 5.30 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. |
| 16 | OD149868/2025-2026 ENGAGING COOLIE for shifting and relocating house hold materials while working |
| 17 | 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 18 | 13.88 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 19 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 20 | 5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 21 | 5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 22 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 23 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 24 | 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 25 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 26 | 22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) |
| 27 | 50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 28 | 12.48 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) |
| 29 | 12.49 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). |
| 30 | 50.6.1.5 Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 31 | 50.9.3.1 Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood |
| 32 | 50.9.4.1 Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood |
| 33 | 50.9.1.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 34 | 10.30.1Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows all complete with :4.0 mm thick glass panes |
| 35 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 36 | Supply & Installation of 2 No.s of 6m Solar Mini Mast with 3 No.s of 24W LED Lights |
| 37 | 90.15.3.4Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters |
| 38 | OD146150/2025-2026Supply, conveyance, installation, testing and commissioning of 24W LED street light input voltage range 12.8V DC. Total Luminous flux (Lumens) 105 lm/watt. LED Light source multi LED. Colour Rendering Index (CRI) 80. Beam angle 120. LED Luminous Efficacy 130 - 140 lm. Correlated Colour Temperature (CCT) 6500K.Working Temperature -10C to +50. Rated life of LED 50,000 Hrs. Driver compartment should be separately accessible for maintenance (LM 79 &80 Certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 39 | OD146155/2025-2026Supply and installation of solar pannel polycrystaline SPV modules 150Wp |
| 40 | OD146154/2025-2026Supply and installation of battery bank:768Wh LiFePO4 battery - 2000 cycle(12.8v/60Ah) with overcharge, over load ad low battery protection. Nominal voltage/current of a cell -3.2V/6000mAh.Overcharge 14.8V, over discharge release voltage-9.8V. Upper cut of voltage - 14.6V max. Continuous charging current 10A Max. Continuous discharging curren - 20A approx.Cirtification BIS approved. Including labour charge |
| 41 | OD146153/2025-2026Supply and installation of solar charge controller : Input voltage - 12.8V, input current 2.5amps, output vltage of driver 30v, output current of driver 800mA-900mA,Power consumption 24W +/- 25% including labour charges. |
| 42 | OD146152/2025-2026Supply and installation of Battery box and solar mounting structure : Battery box suitable for fixing 2 nos. of 12.8V 60Ah battery packs, solar mounting structure and accessories for solar panel. |
| 43 | OD146151/2025-2026Supply and fixing of Inter connecting wires and accessories for the solar light system |
| 44 | Civil Work |
| 45 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 46 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 47 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for Foundations,footings,bases of columns, etc for mass concrete |
| 48 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 49 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 50 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 51 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 52 | OD160000/2025-2026Providing and fixing granite of any color and shade for name of the required size laid over base of cement mortar1:4 (1 cement and 4 coarse sand) including all charges etc complete at all levels including leering & fixing |
| 53 | OD149864/2025-2026Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut &Bolt Please Enable Macros to View BoQ information |