|
| 1 | Surface dressing n exc 15 cm deep complete all as specified and as directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard soil complete all as specified and as directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but not exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m but not exc 3.0 m in depth and getting out in hard soil complete all as specified and as directed. |
| 4 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling, mass concrete and sub base of floor complete all as specified and directed. |
| 5 | M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hopping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0,9 mm dia or securing with clips quality confiring to Fe-410 complete all as specified and directed. |
| 6 | All as per item No. 5 but 5mm dia and over upto and incuding 10mm dia in stirrups tie, spacers and binder complete all as specified and directed. |
| 7 | M&L for form work to sides of concrete foundations, footings bases of coloumns raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter for rough finished surface of concrete complete all as specified and directed. |
| 8 | M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases fo columns, basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 9 | M&L for form work to sides of pillars, posts, struts, piers, columns etc or to batter for rough finished surface of concrete complete all as specified and directed. |
| 10 | M&L for RCC M-25 design mix (using 20mm graded stone agg) as in columns, pillars piers, posts and struts complete all as specified and directed. |
| 11 | Returning, filling in including spreading, levelling watering and well ramming in layers not exceeding 25cm in soil complete all as specified and directed. |
| 12 | Removing excavated material to a distance exc 250m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 13 | M&L for moorum filling under floors or paving laid in layers n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.(Note. Moorum to be broght from outside MoD land.) |
| 14 | M&L for Hardcore Broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface |
| 15 | M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mmm graded stone aggregate) as in sub base to floors complete all as specified and as directed. |
| 16 | M&L for Double Vitrified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. over and including 20 mm thick screed bed in CM 1:6 for laying floor finishes and set and jointed in neat cement slurry and pointed in white or coloured cement to match.Note : Vitrified tile shall be double charged shade as approved by GE based on manufacturers catalogue. |
| 17 | M&L for vitrified tile 8-10 mm thick as in skirting/riser of steps including 10 mm thick back coat in CM 1:4 complete all as specified and as directed.Note : Vitrified tile shall be double charged shade as approved by GE based on manufacturers catalogue. |
| 18 | M&L for Brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar (CM) 1:6 complete all as specified and directed. |
| 19 | M&L for 15mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified and as directed. |
| 20 | M&L for 10mm thick cement plaster in CM 1:6 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified and directed. |
| 21 | M&L for preparation of new plastered surface and applying two coat of internal emulsion paint over a coat of primer over 3 mm thick wall care putty of approved make on wall surfaces complete all as specified and as directed. |
| 22 | M&L for applying two or more coats of 100% premium external emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 23 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 24 | M&L for RCC M-25 design mix (using 20mm graded stone agg) as in lintel beams, roof beams, cantilevers, chajjas bressumers, lintels over 1.5m span complete all as specified and directed. |
| 25 | M&L for form work to edges of rough finished surfaces of concrete flats, treads, breaks in floors, windows cills, concrete railing, openings in concrete walls floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20 cm wide complete all as specified and directed. |
| 26 | S&F steel work in tubular trusses, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St.-240 complete fabrication and erection at site as per drgs. |
| 27 | S&F framed work as in plates (plain or chequred) channels, square cut or notched with fabriction and erection of Fe 410-W (Gde E-250) quality A (ordinary and counter sunk) forming holes over and including anchor bolts of required sizes complete all as shown in drgs. |
| 28 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 thick of an colour having tensile strength of 550 mPa as in roof covering /cladding to wall, fixed with self tapping scews as specified. |
| 29 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mPa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 30 | M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of aluminium paint over a coat of aluminium primer complete all as specified and directed. |
| 31 | M&L for 18 to 20mm thick Granite (Telephonic black/Ruby red) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite all as specified and directed. |
| 32 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar work. |
| 33 | M&L for Aluminium (minimum 50 micron powder coated) frame for doors, window, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 34 | M&L for min 6 mm thick float glass plain or tinted ordiner quality, fixed in windows. |
| 35 | S&F 12 mm thick toughned glass door over and including all fittings and fixtures i.e. locking arrangements, double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass,other parts made of mild steelheavy duty and fixedpivot floor spring complete all as approved by Garrison engineer. |
| 36 | S&F PVC (SWR) 150 dia pipe single socketed in any length with rubber ring joints fixed to walls over and including necessary fixing arrangements to take roof water into rainwater pipe complete all as specified and directed. |
| 37 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) |
| 38 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 39 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 40 | M&L for providing and laying 60mm thick factory made pre stressed precast cement concrete inter locking paver block of M-35 grade (with grey cement and pigment) confirming to IS 15658-2006 and ISI marked with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required shape, made by table vibratory method using PU mould, laid over 50mm thick compacted sand, compacting and proper embedding, filling the joints with sand complete all as specified and directed. |
| 41 | S&F in position suspended false ceiling system using T-grid suspended ceiling grid system. The size of grid shall be 600x600mm with GI frame work main runner 38x24x3600mm, cross tee 25x24x600mm/ 25x24x1200 mm and wall angle 24x24x2540mm (thickness of the materail of 0.30mm) using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in the drop texture as per IS-2095, Part-I 1996, fixed in the T-grid suspended ceiling system duly susupended by 4mm dia GI bar hanged from the purlins of the roof with butter fly clips complete all as specified and directed. |
| 42 | M&L for submain wiring with two single core PVC insulated unsheathed, FRLS type, multistranded flexible copper conductor 1100Volts grade cables 2x2.5 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 2.5 Sqmm 1100 Volts grade PVC insulated unsheathed multi stranded, FRLS type flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified & directed. |
| 43 | M&L for point wiring complete with and including single core PVC insulated unsheathed flexible bright multistranded copper conductor cables 1.5 Sqmm (22/0.30mm) 1100 Volts grade FR type drawn through & including heavy duty/grade PVC non -metallic PVC rigid conduit and it accessories such as tee elbow, jointer, elbow corner etc fixed on surfaces of walls, columns/beams by means of cadmium plated screws and sunk cup washers along with 1.50 sqmm PVC copper conductor cable as a earth continuity earth wire & connected to commen earth dolly at one end and metallic bodies at other end including adequate size of PVC boards for mounting switches, sockets fan regulator etc for One light and fan point on with other switches including earth wire all as specified & directed. |
| 44 | All as per Item No. 43.00 but One 5 Amp 5 pin socket outlet point on independent board with ofter switches including earth wire as specified. |
| 45 | All as per Item No. 43.00 herein before but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 4.0 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including PVC/wooden folding boards for mounting purposes complete all as specified & directed. |
| 46 | S&F switch piano flush button type 5 Amps single pole one way complete all as specified & directed. . |
| 47 | S&F switch socket combination 2 in 1, 5 Amp flush type complete all as specified. |
| 48 | S&F switch socket combination multipurpose flush type 2 in 1 type 3 and 3 pin 5/15 Amps, 230V AC complete all as specified & directed. . |
| 49 | S&F fan regulator electronic on existing phenolic laminated sheet socket type 230 Volts, 450 Watts suitable for ceiling fan 1200/1400mm sweep complete all as specified & directed. |
| 50 | S&F invertor LED luminaire 600x600mm, 36 Watt, 220 Volts AC recessed/ surface type fittings, epoxy powder coated CRCA sheet housing with electronic driver, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified & directed. . |
| 51 | S&F ceiling fan 1200mm sweep, AC, 230 Volts with blades, down rods complete with brushless direct current motor (BLDC) motor, five star star rated, value 6.00 BEE and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified & directed. |
| 52 | S&F distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's with bus bar with front openable cover suitable for SP & N 8 ways all as specified & directed. |
| 53 | S&F MCB TPN 32 Amps, 415 Volts, 50 Hz with 10 kA. |
| 54 | S&F MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 kA. |
| 55 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 4 core 25 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed. |
| 56 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed. |
| 57 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 58 | M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and directed. |
| 59 | M&L for pole Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI wire 4.0 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”. Please Enable Macros to View BoQ information |