| 1 | Schedule 'A' |
| 2 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Material and labour for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15mm Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes and rubbing and polishing, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material and labour for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab over 10mm cement mortar of 1:4 including rubbing and polishing, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Demolition of Reinforced cement Concrete of any description and in any position not otherwise specifically provided for (reinforcement cutas required to facilitate demolition), complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material and labour for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material and labour for coloured glazed ceramic coloured tiles of size 450 x 300 x 7mm thick in vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat in 10mm thick with Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material and labour for Porbandar stone masonry well bonded, bedded and solidly hearted built in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material and labour for rendering 15mm thick, cement plaster, in cement mortar (1:4) on wall surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Material and labour for RCC M-30, using 20mm graded stone aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as specified, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Use and waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Material and labour for cement concrete in foundations, filling and mass concrete Type D-2, 1:4:8 (40mm graded aggregate), complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material and labour for cutting into old masonry work including making good in cement mortar of the same mix as for new walling, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material and labour for preparing old plastered / decorated surface of wall including cornices etc., by brooming down and applying one coat of oil bound distemper including a wherever required of wall putty including smooth roller finish, complete all as specified and directed by Engineer-in-Charge. Note:- After painting, cleaning of all floors, glass, Supply & Fixing Furniture by own arrangement. |
| 16 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of acrylic emulsion exterior grade over a coat of primer, including all necessary scaffolding etc., complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material and labour for Mirror polishing on marble/ granite/ Kota stone/ stone work where-ever required to give high gloss finish, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Material and labour for supply erection fabrication of Kitchen heavy duty Exhaust GI Ducting 500 x 500 to 300mm x 300mm with Stainless steel Chimney 1800 x 1500mm with exhaust fan 2HP and other hanging accessories fixed, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Material and labour for erection & fabrication of cooking table of size 2400mm x 1500mm x 900mm height telephone granite table top heavy GI frame 6mm MS sheet, Drawers made with waterproof plywood 18mm, laminate sheet 1.25mm thick with anti-rusting epoxy paint heavy duty soft closing telescopic channels of make HETTICH, Gas pipe line 6 mtr, gas control valve with hose nipple and fittings as per site requirement, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material and labour for Cabinet made of Plywood with heavy laminate of 1.25mm thick decorative type of size 3000mm x 600mm x 300mm, shutters having profile shutters made with heavy duty aluminium profile section powder coated with 4mm toughened glass, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material and labour for WPC Shutters with frame for cabinet as per site including complete heavy duty fittings, handles, hinges, etc. having size 3000mm x 600mm. Without any type of civil work, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material and labour for cabinet made of 18mm thick WPC of size 2100 x 2000 x 850mm having shutter named as profile shutter, complete with hinges etc., complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material and labour for removing existing treatment of floor and prepare to receive epoxy flooring by scratch with wire brush, clean dirts etc., complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material and labour for laying 2-3mm thick self-levelling epoxy flooring system over prepared concrete surface including surface preparation, priming, application of epoxy screed and top coat complete as per manufacturer's specification, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material and labour for applying floor marking lines as per described width over finished epoxy flooring using epoxy/ PU based line marking paint of approved colour and shade, complete as per approved layout, complete all as specified and directed by Engineer-in-Charge. |
| 26 | E/M Part |
| 27 | Material & Labour for sub main wiring with two single core 2 x 4 Sqmm PVC (FRLS) insulated multi-stranded flexible copper conductor cable 660/1100 volts grade down in through including Steel Conduit with all accessories, PVC insulated 1 x 4 Sqmm single core single strand copper conductor as continuous earth wire in green colour connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge.Note : 1. Two runs of cable, one run of earth wire, one run of Steel conduit will be measured and paid one unit. |
| 28 | Supply & Fixing metal clad plug & socket board Single pole and neutral enclosure with two pin and earth metal plug & socket complete with 20 Amp MCB SP, C curve, complete all as specified and directed by Engineer-in-Charge.Make- Anchor/Legrand/L&T |
| 29 | Supply and fixing MCB SP 5-32 Amp, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at Cooling Mode.Air conditioner will have following conditions:-(i) Refrigerant - R 410a (ii) EER - min 3.5 w/w (5 star rating)(iii) Tonnage - 1.5(iv) Indoor Noise Level - Not more than 48 Db(v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter(vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo modeAll specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make : Voltas/Hitachi/Blue Star |
| 31 | Note:- Following will be inclusive in rate for item no 1 :-(a) Piping length upto 15 mtr will be inclusive in item(b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge(c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe(d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge(e) Contractor will provide warranty of 5 years for compressor from the date of installation(f) 5% of Air conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air conditioner(g) Contractor provide complete free service in warranty period by the company |
| 32 | Material and labour for providing point wiring with two runs of 4 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 4 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous Earthing complete in and including PVC casing and capping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing earth plug & sockets 20 Amps, complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply & Fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 230 Volts complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider |
| 34 | Material & labour for Sub main wiring with two runs of 4.00 Sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC casing capping, wall surface, making good the disturbed surfaces of walls/ceiling/floor etc., including accessories and one run of 4.0 Sqmm single core PVC insulated but unsheathed multi-stranded copper conductor 1100 volts grade cable as earth conductor, complete all as specified and directed by Engr-in-Charge. Note: All runs of cable and 1 run of conduit/casing capping shall be measured and paid as one metre length of unit. |
| 35 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out Hard/ dense soil, complete all as specified and directed by Engr-in-Charge. |
| 36 | Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 37 | Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 38 | Supply and laying Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 40 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor, complete all as specified and directed by Engr-in-Charge. Make: Gemini/Rex/Poly |
| 39 | Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor of size 95 sqmm 3.5 core, 1100 volts grade of cross-sectional area, complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |