| 1 | Demolition brick work / block masonry or stone/ boulder masonry, built in built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 2 | Taking down cement plaster on brick or conc surfaces including racking out joints hacking for key, scrubbing down with water etc. |
| 3 | Excavating over areas, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and as directed by Engr-in-charge. |
| 4 | –ditto- All as per Item No 2 but exc 1.50 M and nexc. 3.0 M in depth complete all as specified and as directed. |
| 5 | Returning filling in including spreading levelling watering and well ramming in layers n exc 25cm thickness complete all as specified and as directed by Engr-in-charge. |
| 6 | Removing excavated soil to a distance n exc 50m and depositing at alevel n exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge. |
| 7 | M & L for Hardcore of Broken bricks of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 8 | M&L PCC (1:3:6) type C2 using 40 mm graded stone agg as mass concrete for foundation complete all as specified and as directed. |
| 9 | M&L for pre cast cement concrete block masonary of 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) with soild blocks, exc.10cm in width, set and jointed in cement mortor 1:6 complete all as specified and directed. |
| 10 | M&L for pre cast cement concrete block masonary of 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) with soild blocks, using old concrete blocks obtained from the demolition, exc.10cm in width, set and jointed in cement mortor 1:6 complete all as spd and directed. |
| 11 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed. |
| 12 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, using old stones/boulders obtained from the demolition complete all as specified and as directed. |
| 13 | M&L For PCC type B1(1:2:4) using 20 mm graded cushed stone agg as in coping ,benching and the like incl form work complete all as specified and as directed. |
| 14 | M&L rendering 15mm thick in cm 1:4 concrete or brick surfaces as in wall finishes even andsmooth w/o using extra cement incl mixing of wpc @ 3% complete all as specified and as directed. |
| 15 | Supply only Integral waterproofing compound complete all as specified and as directed. |
| 16 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including the pipe inserted in man holes walls etc. for undermentioned drain pipes, including removal of rubbish outside MD land Complete all as specified and directed. |
| 17 | Demolition and breaking up 200mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including the pipe inserted in Man holes walls etc. for undermentioned drain pipes, including removal of rubbish outside MD land Complete all as specified and directed. |
| 18 | S&F, 150mm dia bore (inner dia) double wall corrugated HDPE Pipe (SN-8) in any length including all fittings and jointing with eastomeric rubber link and cuppler /other jointing materials laid in trenches are in floors all as sfd and directed by Engr-in-charge. |
| 19 | S&F, 200mm dia bore (inner dia) double wall corrugated HDPE Pipe (SN-8) in any length including all fittings and jointing with eastomeric rubber link and cuppler /other jointing materials laid in trenches are in floors all as sfd and directed by Engr-in-charge.Note :- The cost for desludging sludge and removing of soil/silt/girt/sludge waste material etc, is deemed to be included in unit rate in Ser item No 8, 9, 10, 11, 18 & 19. |
| 20 | M&L for providing cement concrete 1:3:6 type C-2 bed to 150mm bore of drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for Complete all as specified and directed. |
| 21 | M&L for providing cement concrete 1:3:6 type C-2 bed to 200mm bore of drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for Complete all as specified and directed. |
| 22 | Cutting in to existing manholes for forming new drains and making good to pipe and making good to pipe and rendering ,cutting out existing benching in cement conc 1:2:4 type B1(in 1/2 or 3/4 round in section)and reforming benching as reqd for 150mm bore pipe Complete all as specified and directed. |
| 23 | Demolition of reinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 100 metre above the starting point complete all as specified and directed |
| 24 | M&L for providing precast reinforced cement concrete type A1, 1:1.5:3 using 20mm graded aggregate as in landings, cover slabs (for man holes etc) and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match including use of necessary formwork Complete all as specified and directed.Note : S&F reinforcement shall be measured and paid separately. |
| 25 | M&L for reinforced cement concrete type B1, 1:2:4 using 20mm graded aggregate as in slabs supported on walls, beams, and column in floors, roofs, landings, balconies, canopies, deck slabs annd in shelves Complete all as specified and directed. |
| 26 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and as directed by Engr-in-charge. |
| 27 | Dismantling structural steel work including doors and gates of any description complete all as specified and as directed. |
| 28 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete and conforming to Fe 410-W Gde E-250 quality 'A',complete all as specified and as directed. |
| 29 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for Rough finished flat surfaces of concrete complete all as specified and as directed. |
| 30 | M&L Non-Skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:6 for laying floor finishes incl dismantling floor tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed. |
| 31 | S&F in repairs viterous China squatting pan or Orissa pattern 580 x 440 mm white with integral foot rest (excluding cistern) with front or back inlet ant pattern as in repairs incl bedding with p.c.c type B-I 1:2:4 , using 20 mm graded crushed stone aggregate Complete all as specified and directed. |
| 32 | S&F in repairs viterous China wash down water closet pan (pedestal pattern white (excluding flushing cistern and flush pipe) complete all as specified and as directed by Engr-in-charge. |
| 33 | S&F in repair 10 ltrs capacity incl PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets including flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern, complete all as specified and as directed. |
| 34 | Dismantling of 75 / 110mm bore cast iron, PVC or reinforced concrete pipes jointed in cement mortar and taking out of trenches if reqd of any dia Complete all as specified and directed. |
| 35 | S&f 110mm bore PVC (SWR) pipe ISI marked single socketed, in any length with rubber joints fixed to walls complete all as specified and as directed by Engr-in-charge. |
| 36 | S&f 75 mm bore PVC (SWR) pipe ISI marked single socketed, in any length with rubber joints fixed to walls complete all as specified and as directed by Engr-in-charge. |
| 37 | S&f 110 mm bore PVC (SWR) pipe ISI marked single socketed, in any length with rubber joints laid in trenches or in floors complete all as specified and as directed by Engr-in-charge. |
| 38 | S&f 75 mm bore PVC (SWR) pipe ISI marked single socketed, in any length with rubber joints laid in trenches or in floors Complete all as specified and directed. |
| 39 | S&f 110mm bore PVC (SWR) pipe bends ISI marked ovel access door any radius complete all as specified and as directed. |
| 40 | S&f 75mm bore PVC (SWR) pipe bends ISI marked any ovel access door radius complete all as specified and as directed. |
| 41 | S&F 75mm bore PVC (SWR) junction single, (Single T) ISI marked equal or unequal complete all as specified and as directed. |
| 42 | S&F 110mm bore PVC (SWR) junction single, (Single T) ISI marked equal or unequal complete all as specified and as directed. |
| 43 | S&F 75mm bore PVC (SWR) vent cowl ISI marked complete all as specified and as directed. |
| 44 | S&F 110mm bore PVC (SWR) vent cowl ISI marked complete all as specified and as directed. |
| 45 | M&L 75 mm bore PVC (SWR)) floor traps with grating incl jointing with solvent cement complete all as specified and as directed. |
| 46 | M&L 75 mm bore PVC (SWR)) multi floor trap with grating including jointing with solvent cement complete all as specified and as directed. |
| 47 | M&L 75 mm bore PVC (SWR)) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 48 | S&F PVC (SWR) 'P'/S trap 110mm bore for ind type w/c complete all as specified and as directed. |
| 49 | S&F Grating doom 125 mm with waste hole of CP complete all as specified and as directed. |
| 50 | Cleaning/desilting of the drains by removing foreign materials / silt/ greasy materials / earth from the drains, bed/bottom width of drain exc. 30 cm, removing the excavated material from site to a distance n exc. 50 mtrs and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed by Engineer-in-Charge. |
| 51 | Deduct Schedule of Credit of Rs (-) 136050.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |