| 1 | Sub Head - I : EI & FANS |
| 2 | Providing day to day running operation, routine maintenance and preventive maintenance electri sub station comprising of2 nos x 1600 KVA capacity oil filled transformer, feeder pillars, LT, HT Panels & switch gears, cables ,protective equipmentsas required and 2 nos x 750 KVA capacity DG Sets installed at CBPACS, Khera Dabar round the clock i/c sunday & holidays keeping the all installation neat & cleanalways and maintain the all relevant with scope of works and terms & conditions by deploying staff as following with all necessary instruments, insulation tape, test lamp, tester, cleaning materials ,sundaries, dusters & detergent etc.as complete as required as per terms & conditions : |
| 3 | (a) Operation & maitenance of Lfts :-(i) Lift Operator - 04 Nos. (Round the clock, 1 no in each shift and 1 no i no in general shift)(b) Operation & maintenance of WTP of capacity 25000 LPH :- (i) Operator (E&M) - 03 Nos. (Round the clock)(ii) Khallasi -1 no in general shift(c) Operation & maintenance of Sub station & DG Sets :-(i) Electrician/wireman/ DG Set operator (E&M) - 03 Nos. (Round the clock)(ii) Khallasi -1 no in general shift (d) Operation & maintenance of HVAC/ central AC plant :-(i)AC Mechanic/ Operator (E&M) - 03 Nos. (Round the clock)(ii) Khallasi -1 no in general shift(e) For E I work i/c compond lights of whole campus i/c non residential, hostel & residential complex :-(i) Wireman Cum Pump Operator - 04 Nos. (Round the clock, 01 Nos. in Each Shift and 1 no in general shift)(ii) Khallasi- 4 nos (Round the clock, 01 Nos. in Each Shift and 1 no in general shift)(f) Operation and maintenance of STP of 300 KLD :-(i) STP Operator - 3 Nos. (Round the clock, 1 no. in each shift).(ii) Kallasi - 01 No. ( In General shift) |
| 4 | Sub Head – II Maintenance of window /Split Air conditioners |
| 5 | Comprehensive, Routine & Preventive maintenance i/c servicing of 98 nos. of various make 1.5 and 2.0 TR capacity WTAC/STAC & 17 Nos. water cooler of 80 Ltrs. storage capacity (as per Inventory attached) i/c attending day to day complaints from 9 AM to 5 PM by deputing minimum following staff (to report to JE(E) daily) and rectify the defects, supplying and replacement of wornout parts such as starting / running capacitors, starting relays, overload relay, tharmostat, selector switches, sleeves, knobes, connector and associated control wiring, filter, drain pipe etc which required to be replace during routine maintenance and monthly cleaning of filters etc. (Replacement of compressor, condensor unit, cooling coil unit, blower, fan blower motor, front grill, man leads, gas charging etc not covered under routine maintenance) complete as per terms & conditons and Engineer-in-Charge. (98 Nos.)(a) AC Mechanic - 1 No(From 1 april 2026 to 30 september 2026) |
| 6 | Dismantling & Re-installation of exisiting installed STAC / WTAC of 1.5 TR & 2.0 TR capacity with outdoor unit from its location to another location, unloading for reinstallation checking for unit, inspection and reconnection of drainage pipe, reconnection and tightening the loose connection, testing the machine etc as reqd. |
| 7 | Supplying & fixing of following capacity compressor in the existing WTAC / Split AC making copper pipe connection, brazong pressure testing and supplying and charging M-22 refrigerant gas charging i/c cutting the copper piping dismantling of the old compressor complete as reqd. |
| 8 | Compressor - 1.5 TR |
| 9 | Compressor - 2 TR |
| 10 | Providing and fixing WTAC /STAC fan motor capcity 1/4 to 1/8 HP i/c dismantling the burnt out motor from the existing unit & fixing of new motor making connection, testing complete etc as reqd. |
| 11 | Supplying & charging of M-22 / R-22 gas in the exising WTAC / STAC of 1.5TR unit i/c pressure testing, flushing the system & gas charging complete etc as reqd. |
| 12 | Supplying & charging of M-22 / R-22 gas in the exising WTAC / STAC of 2 TR unit i/c pressure testing, flushing the system & gas charging complete etc as reqd. |
| 13 | Repair of damaged PCB of indoor and outdoor unit i/c tightening the loose connection, testing the machine etc as reqd. |
| 14 | Supplying & fixing of copper refrigerant pipe of size 1/4\\", 5/8\\" with insulation and copper wire 3 core 80-20 i/c all connection in the existing AC units i/c dismantled as per reqd at site. |
| 15 | Supplying and replacement of remote control system with remote (wireless/with wire remote) in the existing installed window/Split Type AC i/c all interconnection, testing and commissioning complete as reqd. |
| 16 | Supplying and fixing of 1.5 / 2 TR capacity WTAC/ Split AC cooling coils i/c pressure testing after removing the leakage with brazing, flashing the system , vaccuming the system, checking & repairing interconnection complete in all respect as required at site. i.c dismantled of old material etc. as reqd. |
| 17 | Supply & Replacement of 1.5 / 2 TR WTAC / STAC burnt out / defective copper condenser coil with new one of the same size and design suitable for 1.5 TR Split type AC Out Door unit i/c breezing the all copper pipe with all distribution joint's and make sure the connections with capillary tube linking dryer duly proper etc. Nightrogen pressure testing, leak detections, vaccumizing the unit, complete as reqd. i/.c dismantled of old material etc. as reqd. |
| 18 | Sub Head - III : Sub Station & DG set |
| 19 | Operation and Maintenance of Sub Station |
| 20 | Drawing out Alstom make VCB with the help of Rotating draw out handle panel and servicing / Overhauling of existing Alstom make, VCB of 11 k v, 630 amps, 18.4 KA (1 sec) rating, checking and Cleaning of VCB interrupter contacts with waste cloth, Blower, tetrachloride etc. checking and cleaning of Auxiliary contact (NO/NC) with CTC & bus bar with CRC2-26 spray I /c checking of 24 volts closing/ Trapping mechanism, bus bar insulators, spout Insulators etc. meggering of VCB on opening/ closing, High voltage testing for vacuum interrupter, continuity Test for VCB contacts, testing of battery charger unit for 24 volt DC tripping function checking & testing of Current transformer (150/5A) of 0.5 accuracy & Potential transformer of 110 volts, electrical & Mechanical interlocking, earth continuity testing for HT Panel etc. complete i/c greasing, setting for spring, Charging gear tripping and closing, roller greasing etc. And re fixing the VCB in its chamber, testing, Commissioning complete in all respect etc. as reqd |
| 21 | Servicing/overhauling of existing 800Amp to 2500 Amp Capacity air circuit breaker of L&T / Schneider I Legrand. /CG make including testing and re- commissioning as required, cleaning of breaker with CRC & checking of Control wiring, arcing contacts, microprocessor/ Thermal magnetic release, alignment, arc chutes, CT'S, Reset & tripping mechanism and connections i/c Carrying out contact resistance test, Insulation test and IDMT/Numerical relays calibration & tripping Mechanism and connections etc. complete as required. |
| 22 | Testing and calibration of IDMT relay set having 2 Nos. O/L and one No. earth fault relay installed in the Existing HT panel by secondary injection method, Cleaning the contacts, resetting with required accuracy Complete checking & setting of control winng lie ro fixing of the relay unit etc complc to is reqd. |
| 23 | Dehydration of the transformer oil of existing 2 nos. transformer with the help of dehydrate machine as reqd. i/c conducting testing of dielectric strength up to 50-60 BDV of the dehydrated oil and submitting the test report as reqd |
| 24 | Supply and filling of transformer oil in the existing Transformer for topping / replacement i/c Test ng of die electric strength of transformer oil after Filling, complete as reqd. |
| 25 | Servicing of 11 KV/110 Volts PT i/c removal of PT from HT panel board, cleaning of dirt particles, tightening, Connection i/c checking of wiring, replacement of Gaskets of top cover, reassembly, i/c Hi pot machine, Testing and commissioning etc. complete as reqd. |
| 26 | Supplying & refilling of silica gel (1 Kg) in the existing Silica gel enclosure of ONAN type transformer Complete. testing etc as required. |
| 27 | Servicing, checking & cleaning of the existing LT panel i/c tightening of nut bolts, Bus Bar joints etc as reqd. |
| 28 | Servicing, checking & cleaning of Ihe existing HT panel i/c tightening Of nut bolts, Bus Bar joints etc as reqd. |
| 29 | Servicing, checking of 1600 KVA Transformer i/c performing of required test cleaning etc complete as reqd. |
| 30 | Sub Head -IV : Repairing of drinking water Pump sets and other work |
| 31 | Taking out of Submersible pump sets with G.I. Pipe and submersible cable and rope wire from bore well with the help of try pot & chain pulley block complete etc. as reqd |
| 32 | Rewinding of submersible/mono submersible Motor of following raiting including cutting the burnt winding wire including rewinding the same with high quality motor resistance PVC Insulatted coper winding the wire i/c replacement of worn out acessories such as GM bearing, thrust plate, thrust bearing etc. testing commissioning complete i/c dismantling etc as reqd. |
| 33 | 7.5 HP |
| 34 | Lowering of duly repaired submersible pump sets into the bore Well with the help of try pot & chain pulley Block with submersible cable & rope wire i/c providing new Nuts Bolts rubber gaskit etc. as reqd. |
| 35 | Supplying & Fixing submersible copper cable of following size along with the motor & G.I. pipe in the exiting bore well complete etc. i/c dismantling of existing cables etc as reqd. |
| 36 | 3X4 Sqmm. |
| 37 | Supplying & Fixing steel wire rope of size 8 mm. Dia i/c PVC coated with submersible sets i/c clamping with the pipe etc.i/c dismantled material as reqd. |
| 38 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. |
| 39 | 50 mm |
| 40 | SITC of 5 HP , 25 stage Submersible pump sets suitable for discharge of minimum 50LPM on head of 10-123Mtrs and making all suitable connection with three phase, 415 Volts, 50 Hz A.C. supply i/c lowring and dismantling etc. as reqd. |
| 41 | SH-V:- Suppy of material |
| 42 | Following material /electrical accessories shall be supply by agency suitable for existing different type switch box / fitting and existing man power shall be used for replacement on day to day maitenance works etc as required. (Labour already included in Item No. 1 o Sub Head - I : EI & FANS ) |
| 43 | S.P. 5/6 amps, one way modular switch, ISI marked |
| 44 | 3 pin 5/6 amps modular socket outlet, ISI marked |
| 45 | S.P. 15/16 amps, one way modular switch, ISI marked |
| 46 | 15/16 Amp Modular Socket |
| 47 | 6 to 32 Amp c Curve SP MCB, \\"C\\" curve, 10 kA breaking capacity |
| 48 | 6 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity |
| 49 | 6 amps. to 32 amps. ratings , SPN MCB, “C” curve, 10 KA breaking capacity |
| 50 | 6 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity |
| 51 | 6 amps. to 32 amps. ratings , TPN MCB, “C” curve, 10 KA breaking capacity |
| 52 | Single pole, blanking plate |
| 53 | 40 amps., 2 pole isolator |
| 54 | 63 amps., 2 pole isolator |
| 55 | 40 amps., 4 pole isolator |
| 56 | 63 amps., 4 pole isolator |
| 57 | 1.5 Sq.mm FRLS Cu wire |
| 58 | 4 Sq.mm ISI marked FRLS PVC wire |
| 59 | 6 Sq.mm FRLS Cu wire |
| 60 | 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 61 | 16 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 62 | Co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid protected with PVC sheath |
| 63 | 1 pair, 0.5 mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, telephone cable |
| 64 | 2 pair, 0.5 mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, telephone cable |
| 65 | 2.50 mF capacitor |
| 66 | Ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req 1200 mm sweep Ceiling fans 1200mm, service value ≥ 6.0CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 67 | 300 mm sweep heavy duty exhaust fans |
| 68 | 380 mm sweep heavy duty exhaust fans |
| 69 | 450 mm sweep heavy duty exhaust fans |
| 70 | 250 mm sweep PVC Air Ventilation fans |
| 71 | 450 mm sweep heavy duty aluminium blade Air Circulator fans |
| 72 | 3 mm thick phenolic laminated sheet |
| 73 | Ceiling rose, 3 pin, 5 amps ISI marked |
| 74 | Call bell/ buzzer, single phase |
| 75 | Stepped type Modular Fan regulator (2 module) |
| 76 | Telephone Socket outlet modular type |
| 77 | Modular blanking plate |
| 78 | Modular bell push, ISI marked |
| 79 | Electronic driver (5W to 12W) LED fixture |
| 80 | Electronic driver (15W to 22W) LED fixture |
| 81 | Electronic driver (36W/40W to 70W/75W) LED fixture |
| 82 | Modular base & cover plate for 1 module |
| 83 | Modular base & cover plate for 2 module |
| 84 | Modular base & cover plate for 3 module |
| 85 | Modular base & cover plate for 4 module |
| 86 | Modular base & cover plate for 6 module |
| 87 | Modular base & cover plate for 8 module |
| 88 | Modular base & cover plate for 12 module |
| 89 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 90 | 18- 22 watt |
| 91 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 92 | 12 -15 watt |
| 93 | Supply of LED Bulk Head fitting not more than 10 W, System efficacy not less than 100 lumens / watt, System output not less than 1000 lumens / watt, CRI>80 and CCT= 5500-6500K and IP-66 rated with aluminium die cast housing & frostrated glass diffuser complete as required. |
| 94 | 600 mm long nominal size LED batten mirror light fitting made out with Aluminium die cast housing and Poly carbonate diffuser with all accessories having rating not more than 10 W, System Efficacy not less than 100 lm/W, lumens output not less than 1000, CRI >80 complete etc. as required. |
| 95 | 3 Pole Power Contactor ( Type ML 2 ) |
| 96 | 3 Pole Power Contactor ( Type MNX-70 ) |
| 97 | Digital Timer Switch |
| 98 | Supplying of water geyser having capacity of 25 Ltr., 5 Star rating suitable for 1-¢, 230 V, 50 Hz, AC supply |
| 99 | Supply of 2000 W Heating Element coil suitable for existing Water geysers at site suitable for 1-¢, 230 V, 50 Hz, AC supply |
| 100 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 101 | 36 watt |
| 102 | Supply of square shape of size 220 mm x 220 mm recess mounting type 15-18 watt LED downlighter in powder coated white finish with 5700K-6000 K colour temperature suitable for 1-¢, 230 V, 50 Hz, AC supply |
| 103 | SH-VI:- Credit of Dismantled material |
| 104 | Less Credit cost for following old dismantled materials |
| 105 | Copper winding wire of 5/7.5 HP motors |
| 106 | copper submersible cable |
| 107 | Steel rope wire |
| 108 | GI pipe 50 mm dia |
| 109 | AC Compressure 1.5 TR |
| 110 | AC Compressure 2 TR |
| 111 | WTAC/STAC fan motor |
| 112 | AC Copper refrigerant pipe associated |
| 113 | 5 HP Submersible p/set |
| 114 | 2.5 mfd condensers |
| 115 | 5/6A/ 15/16A Switch/ Socket/ bell push/ 2 way switch |
| 116 | Call Bell |
| 117 | c' curve SP MCB 6-32A |
| 118 | 6-32A DP MCB 'c' curve |
| 119 | 6-32A SPN MCB 'c' curve |
| 120 | 6-32A TP MCB 'c' curve |
| 121 | 6-32A TPN MCB 'c' curve |
| 122 | Call bell/ buzzer, single phase |
| 123 | 1.5/4.0 sqmm. FRLS Copper conductor cable |
| 124 | 6.0 sqmm. FRLS Copper conductor cable |
| 125 | 1 pair, 0.5 mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, telephone cable |
| 126 | 2 pair, 0.5 mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, telephone cable |
| 127 | Ceiling fan |
| 128 | LED Panel light 2x2 ft. |
| 129 | Exhaust Fan/ Fresh Air Fan |
| 130 | Street light fittings /Post Top Lantern Fittings |
| 131 | LED Down lighter |
| 132 | LED Batten light |
| 133 | LED Bulk Head fitting |
| 134 | LED batten mirror light fitting |
| 135 | Modular base & cover plate for 1,2,3,4,5,6,7,8 & 12 module |
| 136 | Digital Timer Switch |
| 137 | Modular bell push, ISI marked |
| 138 | Stepped type Modular Fan regulator (2 module) |
| 139 | Telephone Socket outlet modular type |
| 140 | 40 amps., 2 pole isolator |
| 141 | 63 amps., 2 pole isolator |
| 142 | 40 amps., 4 pole isolator |
| 143 | 63 amps/100 amp., 4 pole isolator |
| 144 | 36/40/70/75 W Electronic Chopke/ electronic Driver |
| 145 | 5/12/15/22 W Electronic Ballast/ electronic Driver |
| 146 | 3 Pole Power Contactor ( Type ML 2 ) |
| 147 | 3 Pole Power Contactor ( Type MNX ) Please Enable Macros to View BoQ information |