| 1 | Installation/Dismentling of Air Conditioner Split Type on/from the existing wall and proper fixing/removal of Outdoor unit with proper installation/dsmentling of duct pipes, etc as reqd as per the direction of engineer-in-charge. (MR) |
| 2 | Installation/Dismentling of Air Conditioner WndowType in/from the existing window frame etc as reqd as per the direction of engineer-in-charge. (MR) |
| 3 | Servicing with power jet pump of different type and ratings of Air Conditioners window and split type 1.5 ton / 2 ton capacity with chemical cleaning (without repairing of parts i.e. Compressor, blower motor and gas filling etc.) as required (MR) |
| 4 | Servicing of Water Coolers 150-240 Ltrs capacity including cleaning of tank but without spare parts i.e Compressor, blower motor and gas filling etc. as required (MR) |
| 5 | Supply and replacement and fixing of 1.5 ton capacity compressor for window type Air Conditioner, split type AC, multi split AC including making connections , testing ets as required (MR) rotatry type. (with 5 years guranttee for replacement). |
| 6 | Gas charging with suitable refrigerant window type/ split type AC 1.5 ton and 2 ton capacity complete with vaccuming , breezing, pressure testing, lead testing, welding of copper pipe and leak tetsing changing of stainer as required etc (MR) |
| 7 | Gas and gas charging with suitable refrigerant water cooler capacity of 150-240 ltrs water cooler complete with vaccuming , breezing, pressure testing, lead testing, welding of copper pipe and leak tetsing changing of stainer as required etc (MR) |
| 8 | Supply and fixing of magnet Air conditioner relay for 1.5/2 ton air conditioner including making connection , testing etc as required |
| 9 | Supply and fixing of valve for outdoor unit 1/2\\" including making connection,testing etc as required |
| 10 | Supply and fixing of valve for outdoor unit 1/4\\" including making connection,testing etc as required |
| 11 | Supply and fixing of valve for outdoor unit 5/8\\" including making connection,testing etc as required |
| 12 | Supply and fixing of running capacitor of rating 50mfd including making connection,testing etc as required |
| 13 | Supply and fixing of running capacitor of rating 36mfd including making connection,testing etc as required |
| 14 | Supply and fixing of starting capacitor of rating 100/120 mfd including making connection,testing etc as required |
| 15 | Supply and fixing of starting capacitor of rating 80/100 mfd including making connection,testing etc as required |
| 16 | Supply and fixing of condenser fan motor for outdoor unit including making connection, testing etc as required |
| 17 | Repairing of outdoor motor of AC including winding ,connecting,testing etc as required |
| 18 | Repairing of indoor motor of AC including winding ,connecting,testing etc as required |
| 19 | Supplying and fixing of new indoor motor of AC including connecting , testing etc as required |
| 20 | P/I/T/C of 1.5 Ton 5 Star Split Air Conditioner having rotary compressor ,inverter type and following specifications. (a) Capacity : 1.5 Ton (b) Compressor : Rotary (c ) Condenser Coil : Copper (d) Remote with each A.C. (e) Compressor Warranty : minimum 04 years (f) Refrigerant : R-32 (g) Sleep Mode : Yes (g) Auto Restart : Yes (h) Product Warranty : 01 year (i) Power requirement : 220-240 Voltsj)Star rating-5 Star |
| 21 | P/I/T/C of 1.5 Ton 5 Star rating Window type Air Conditioner having rotary compressor inverter type and following specifications. (a) Capacity : 1.5 Ton (b) Compressor : Rotary (c) Star rating : 5 Star (d) Remote with each A.C. (e) Compressor Warranty : minimum 05 years (f) Refrigerant : R-32 (g) Sleep Mode : Yes (h) Auto Restart : Yes (i) Product Warranty : 01 year (j) Power requirement : 220-240 Volts |
| 22 | Supply and fixing of 1.5 ton split AC copper condensor coil with 100% Copper tubes having dimensions 23\\" X 33\\" OD size 3/8 inch having L shape single row with compatible refrigerant R22 or R32 including rebate for old dismantle condenser coil as approved by engineer in charge |
| 23 | Supply and fixing of 1.5 ton AC copper cooling coil with 100% Copper tubes having dimensions 23\\" X 33\\" OD size 3/8 inch having L shape single row with compatible refrigerant R22 or R32 including rebate for old dismantle cooling coil |
| 24 | Supply and fixing of extra copper pipe, vinyl taping(to cover copper pipe), insulation sleeve including making connnection , testing etc as required as approved by engineer in charge |
| 25 | Supply and fixing of 5 KVA automatic voltage stabilizer copper bound and suitable for 160v to 240 volt complete digital type etc. as reqd. |
| 26 | Suppy and fixing of THERMOSTAT SUITABLE FOR WATER COOLER |
| 27 | Supply and fixing of Indoor airhandling unit of split AC completewithcordless remote and all accessoriesof 1.5 /2.0 etc TRcapacityincluding dismantling ofold/defective indoor unit,gas chargingas perrequirement to make the machinein good condition. Job alsoincludes supply and fixing of all typeof sundry material if required andnoextra payment shall be made. Jobcomplete in all respect with menandmaterial and as per instruction ofsite incharge |
| 28 | Supply and fixing of outdoor airhandling unit(without compressor) of split AC complete and all accessoriesof 1.5 /2.0 etc TRcapacityincluding dismantling ofold/defective outdoor unit,as perrequirement to make the machinein good condition. Job alsoincludes supply and fixing of all typeof sundry material if required andnoextra payment shall be made. Jobcomplete in all respect with menandmaterial and as per instruction ofsite incharge |
| 29 | Rebate for Window type A.C. |
| 30 | Rebate for Split type A.C. |
| 31 | Rebate for old 1.5 ton compressor |
| 32 | Rebate for Magnet A.C. relay |
| 33 | Rebate for out door wall 1/2\\" |
| 34 | Rebate for out door wall 1/4\\" |
| 35 | Rebate for out door wall 5/8\\" |
| 36 | Rebate for running capacitor 50 mfd |
| 37 | Rebate for running capacitor 36 mfd |
| 38 | Rebate for starting capacitor 100/120 mfd |
| 39 | Rebate for starting capacitor 80/100 mfd |
| 40 | Rebate for Condenser fan motor of out door unit |
| 41 | Rebate for indoor motor of A.C. |
| 42 | Rebate for automatic voltage stabilizer 3/5 KVA Please Enable Macros to View BoQ information |