| 1 | Surface excavation n.exc 30 cm deep and averaging 15cm deep in soft/loose soil and getting out complete all as specified and as directed. |
| 2 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and as directed. |
| 3 | Rough excavation not exceeding 1.5 m deep and getting out soft / loose soil complete all as specified and as directed. |
| 4 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 6 | Removing excavated soil to distance exc. 50 m but n exc. 500m and depositing where directed complete all as specified and as directed. |
| 7 | Removing excavated soil to distance exc. 500m but n exc. 1.5 km and depositing where directed complete all as specified and as directed. |
| 8 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 9 | M&L for hard core with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 10 | M&L for hard core with broken bricks of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 11 | M & L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 13 | M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 14 | M&L for 100 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in sub base over and including 50 micron polythene film laid complete all as specified and directed. |
| 15 | M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 16 | M & L for PCC 1:2:4 Type B-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 17 | M&L for 40mm thick PCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in floor complete all as specified and as directed. |
| 18 | M&L for 25 mm thick PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) as in levelling Course, floor/paving ect and finished the surface even and fair complete all as specified and as directed. |
| 19 | M&L for RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in foundations, footings, foundation beams, plinth beams, bases for columns, etc. complete all as specified and as directed.Note : For Item No 19 to 24, Reinforcement will be measured and paid seperately. |
| 20 | M&L for RCC, 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in beams, seismic bands, cantilevers, bressumers and lintels over 1.5 m span complete all as specified and as directed. |
| 21 | M&L for RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in columns, pillar, piers, posts and struts etc. complete all as specified and as directed. |
| 22 | M&L for RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc. complete all as specified and as directed. |
| 23 | M&L for RCC 1:1.5:3, type A-1 (using 20mm graded crushed stone aggregates) as in drain walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 24 | M & L for precast RCC cover slab, 1:1.5:3 type A-1,(Using 20 mm graded crushed stone aggregate ) as in drain/manhole cover slab etc., and set in cement mortar 1:4 including necessary form work complete all as specified and as directed. |
| 25 | M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 26 | M & L for mild steel TMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 27 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 28 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 29 | Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, Circular rectangular or polygonal) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 30 | Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels over 1.5m clear span, cantilevers, shelves including supports overhangs etc also splays between floors and beams for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 31 | Use and waste formwork to faces of wall, retaining walls, parapets, railing and similar work including attached pilasters, buttresses etc vertical or to batter for rough finished surfaces of concrete flat or curved complete all as specified and as directed. |
| 32 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 33 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 34 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 35 | M&L for brick work with fly ash brick with using modular size brick, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 36 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 37 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 38 | M&L for rendering 10mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 39 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 40 | M & L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of 1mm thick (average) wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distemper complete all specified and as directed. |
| 41 | M&L for complete removal of existing finishes/treatment of wall and applying two coat of oil bound distemper over one coat of primer including 1mm thick(average) wall care putty complete all as specified and as directe. |
| 42 | M&L for preparation of newly plastered surface of wall, pilasters, cornices etc and treatment apply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer (X2) complete all as specified and as directed.Make: (a) Asian (Apex ultima). Berger weather coat all gaurd. ICI Dulex (Weather shield Max), Nerolac (Excel total) Make of primer : Asin (X2) or Equivalent Note : Each stage i.e Preparation primer application, first coat and second coat of Apex will be passed by Engr-in-Charge (b) Written warranty for four years is required to be furnished by the contractor for this item. |
| 43 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 44 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:-(i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 with mixing of WPC and surface finished fare and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (ii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer 25/85 @ 1.2litre /Sqm conforming to IS:3384-1986.(iii) APP based polymeric membrane 3mm thick (minimum), weighing 3Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(iv) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. |
| 45 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. |
| 46 | S&F SS-304 grade Stainless Steel outdoor Bench with Back rest, made out of SS square pipe, moulded and welded as per required size and design, 3-Seater capacity, not less than 5ft in length and weather proof complete, each weigh not less than 25 kgs complete all as specified and as directed. |
| 47 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 48 | M&L for MS steel Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. and similar work conforming to Fe. 290.Gde-E-165 complete all as specified and as directed. |
| 49 | M & L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed. |
| 50 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 51 | S&F UV resistant Embossed Polycarbonate Sheet, 6mm thick, 1.20 gm/cm³ density, tensile strength 55 Mpa, fixed to iron framework with SS screws complete including silicon adhesive jointing at lap/joints complete all as specified and directed. |
| 52 | M & L for coloured joint free non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc. over and including 15 mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed. |
| 53 | M&L for Joint free Coloured Non-skid ceramic tiles (Exterior grade paving tiles) 8 to 10mm thick (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor/ etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 54 | M&L for Glazed ceramic tiles glossy series digital wall tile 300x450x7mm 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 55 | M&L for Glazed ceramic tiles (Stonex texture) in vertical surface of compound wall 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 56 | M&L for 15mm thick EPDM flooring, certified 100% hygiene and safer for children, long life with 5 yrs warranty, resistance to abrasion, slipping, indentation & ignition, without joints, etc; comprising including laid with approved adhesive prime coat on concrete surfaces and applying 9mm thick standard approved SBR cushioning layer and final 6mm thick colour EPDM layer laid in approved design complete all as specified and as directed. |
| 57 | S&F 40 mm thick 2nd class hard wood boarding clean sawn, planed one side with butt joints and fixed with nails etc. complete as specified and as directed. |
| 58 | S&F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 59 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 60 | S&F 100 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 61 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 62 | S&F 150mm size aluminium handles, cast type, anodised complete all as specified and as directed. |
| 63 | S & F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed. |
| 64 | S&F powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed |
| 65 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium ventilator shutters (Louvers type), aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc. complete all as specified and as directed. |
| 66 | S & F for powder coated aluminium (Minimum thickness of powder coating 50 Micron) work for doors windows ventilators and partitions (fixed portion) with extruded built up standard tubular sections/appropriated Z sections and other sections of o approved make confirming to IS 733 and IS 1285 fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions ie at top bottom and sides with required EPDM rubber neoprene gasket etc Aluminium sections shall be smooth rust free straight mitred and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing/panelling C P brass/stainless steel screws all complete as per architectural drawing and the direction of engr-in-charge. |
| 67 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EDPM rubber/neoprene gasket required (fitting shall be paid for separated ) with extruded built up standard tubular section/appropriate Z section and other sections of approved make confirmed to IS : 733 and IS;1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber/Neoprene gasket etc Aluminium section shall be smooth rust free straight mitred and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing/panelling C P brass/stainless steel screws all complete as per architectural drawing and the directions of Engr-in-charge |
| 68 | M&L double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty and fixed complete all as specified and as directed. |
| 69 | S&F 5.50mm thick frosted (one side) glass ordinary quality and glazing with rubber beading in square of any size for aluminium doors and portions complete all as specified and as directed. |
| 70 | S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 25mm bore PTMT with epoxy coated aluminium rod and high density plastic ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed. |
| 71 | S & F GI tubing 15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 72 | S & F GI tubing 25 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 73 | S&F 25mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. |
| 74 | S&F bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 75 | S & F 2 way Bib cock, 15mm dia cast copper alloy chromium plated, with wall flange fancy type, crutch or butterfly handles screwed down for iron pipe or for brass ferrule complete all as specified and as directed. |
| 76 | S&F stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe. |
| 77 | S&F fancy type Brass chromium plated 600mm long Towel Rail fixed with screws and wooden/plastic cleats etc. complete all as specified and as directed. |
| 78 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 79 | S & F 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 80 | S&F 10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets, PVC connection pipe 15mm dia, 450mm long etc complete all as specified and as directed. |
| 81 | S & F sinks made of stainless steel 1mm thick (SS-304), kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including 40mm Waste fittings, brass, chromium plated with long screwed shanks and fly-nuts, PVC waste pipe etc complete all as specified and as directed. |
| 82 | S&F 15mm dia swan neck pillar taps fancy type, cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed. |
| 83 | M&L for Granite (of any colour) tile 19-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone with grinding and polishing over and including 15 mm thick screed bed in cement mortar 1:4 including dismantling of old tile of any description complete all as specified and as directed. |
| 84 | S & F vitreous china wash down water closet (padestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for padestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed. |
| 85 | S&F Vitreous china urinal, half stall white (excluding flushing cistern) including urinal spreader, 450mm long PVC connection pipe , 40mm PVC waste pipe & 40mm waste coupling providing and fixing plugs, bedding urinal against wall in mortar 1:2, securing urinal to plug, with and including 60mm long screws, pointing around urinal back in cement, fixing flush pipe, grating and union for discharge pipe complete all as specified and as directed. |
| 86 | S & F PVC connection pipe 15mm bore and 450mm long with PVC PTMT nuts at each ends with rubber washers complete all as specified and directed. |
| 87 | S&F DWCPE (SN8) pipes, nominal dia 150 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer complete all as specified and as directed.Make (DWCPE Pipe): Supreme, Prince, Berlia |
| 88 | M & L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) for drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 89 | M &L for Shingle filling laid in layers n exc. 15 cm thick, spread levelled, and bonded with earth for filling around the DWCPE pipes complete all as specified and as directed. |
| 90 | S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall complete all as specified and as directed. |
| 91 | S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall complete all as specified and as directed. |
| 92 | S & F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed. |
| 93 | S & F 75 mm dia PVC (SWR) bends of any radius complete all as specified and as directed. |
| 94 | S&F 75 mm dia PVC(SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 95 | S&F Salt-glazed stoneware gully trap of size 100mm X 100mm square or round mouthed, type ‘P’ complete all as specified and as directed. |
| 96 | M&L for Cutting into existing manholes for connecting new drains of 150 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and as directed. |
| 97 | Spreading and levelling in layers n exc. 25 cm thick including well ramming and watering as required complete all as specified and as directed. |
| 98 | Rolling and consolidating formation surfaces in cutting using hand roller 0.2 to 0.5 tonne complete for landscaping the entire area covered in surface excavation complete all as specified and as directed. |
| 99 | S & F 60 mm thick machine pressed precast concrete interlocking paver block (Perforated design to allow vegetation growth) of any shape and size confirming to IS 15658:2021 M-35 Grade complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 100 | S & F 60 mm thick machine pressed precast concrete interlocking paver block (Perforated design to allow vegetation growth) of any shape and size confirming to IS 15658:2021 M-35 Grade complete all as specified and as directed. Please Enable Macros to View BoQ information |