| 1 | M & L for one light point/ fan point controlled by one, one way flame proof switch surface type wiring complete with 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through ERW steel conduit heavy duty ISI mark of size 20mm external dia with all accessories like tees, bends elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts saddles, pipe hooks etc as specified |
| 2 | All as per item No 1 but with 2.5 Sqmm all as specified and directed by Engr-in- Charge |
| 3 | M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 1.5 Sqmm single core, copper conductor drawn through ERW steel conduit heavy duty ISI mark of size 20mm external dia and 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed(Note: Two runs of conductor with one run of earth wire will be measured & paid as one unit) |
| 4 | All as per item No 3 but with 2.5 Sqmm all as specified and directed by Engr-in- Charge |
| 5 | Supply and fixing flame proof/weather proof 4 feet LED light fitting 1x20 Watt CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size |
| 6 | S&F flameproof/ weather proof exhaust fan, 18\\" (450mm), single phase,with and including louvers, complete CMRI certified recommended for gas group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing. Make- Sudhir Cat No 140 or equivalent of make Sudhir / Bajaj/CG complete as directed.Note:-The rate quoated shall be in including making holes of suitable for exhaust fan of size 450 mm dia in PCC block masonry wall, making good the side of hole with CM (1:4) on wall with two coat of paint match with existing wall and distributed surface with 4 nos of stainless steel fastner of suitable size to fit the exhaust fan no extra payment will be allowed to contractor on this regard. |
| 7 | Supply and fix Flame proof/weather proof rotory On/Off switch with termination box in LM6, 16A 2 pole 250V. |
| 8 | S&F Flame proof/Weather proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth |
| 9 | Supply and fix Flame Proof Weather proof lighting Distribution Panel :Incoming :- MCB SPN 25 Amp - 1 Nos in each DBOutgoing :- MCB SP 5-32 Amp - 02 Nos in each DB with complete internal bus bar & wiring up terminals. |
| 10 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm ,2 core ® Note :- cable laying on Wall/Ground |
| 11 | Supply and fixing single pointed air termination copper rod, 12 mm dia, 300 mm long. |
| 12 | Supply and fixing copper strip 20 mm X 3.15 mm complete with saddles and fixing screws for roof conductors and down conductors above ground. |
| 13 | M&L for PCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in coping of poles and like incl watering,slightly rounded of chamfered angles and throating incl. necessary form work,complete all as specified. |
| 14 | S&F GI Pipe Light grade of 40mm bore complete with elbows, couplers etc and with MS Clamps, nuts, bolts, washers etc for fixing of pipe to wall/floor and laying in trenches for protection complete all as specified and as directed |
| 15 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil soil complete all as specified and directed by Engineer-in-Charge. |
| 16 | Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed. |
| 17 | Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all specified and directed. |
| 18 | M&L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified. ( Note : For measurement purpose punned thickness shall be considered) |
| 19 | M & L unreinforced precast concrete cable covers CLASS LV type II, flat size 250 x 150 x 40 mm laid transverse to cable. |
| 20 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) not exceeding 1.5m deep including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, in all kind of soil as directed by Engineer-incharge |
| 21 | All as per item No.20 above but exceeding 1.50m and not exceeding 3.0m deep all as specified and directed |
| 22 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete . |
| 23 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surface |
| 24 | M&L for reinforced cement concrete M-25 design mix as in footings, foundation beams, plinth beams, bases for column etc all as specified. |
| 25 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions Square, Circular rectangular on plan |
| 26 | M&L for reinforced cement concrete M-25 design mix in column, pillar, piers, posts and struts all as specified. |
| 27 | M&L for form work to side and soffits of floor or roof beams, lintels, cantilever, shelves including supports etc for rough finished surface of conc all as specified. |
| 28 | M&L for form work to chullah hoods, chajjas,troughs and similar items including edges all as specified. |
| 29 | M&L for Form work Rough finished surfaces of concrete to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified. |
| 30 | M&L reinforced cement concrete M-25 design mix as in chajja all as specified and directed by Engr-in-Charge. |
| 31 | M&L for reinforced cement concrete M-25 design mix in beam and cantilever, lintels over 1.5 m span all as specified. |
| 32 | M&L for form work to soffits of suspended slabs, such as roof slabs floor slabs and similar work not exc 200 mm thick for rough finished surfaces of concrete all as specified. |
| 33 | M&L for reinforced cement concrete M-25 design mix in slab supported on walls, beams and column in floor roof and landing all as specified. |
| 34 | S&F MS TMT bars 10 mm dia and over cut to length bent to shape required incl, cranking bending spirally for hooping for column hooking ends binding with and incl MS wire (annealed) not less than 0.9 mm dia |
| 35 | All as per item No. 34 above but 5 mm dia and over upto and incl 10mm dia in stirrups, spacers and binders. |
| 36 | M&L Pre-cast cement concrete block masonry Type C1 1:3:6 (20 mm graded aggr) with solid blocks, exc. 10 cm in width and setting in mortar, complete set in CM 1:6 |
| 37 | M&L for 25 mm PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) on roof to receive WPT as directed by Engr-in-Charge. |
| 38 | M&L for rendering 10mm thick in CM 1:3 over RCC roof mixed with water proofing compound @ 3% by weight of cement finished even and fair without using extra cement. |
| 39 | M&L preparing the surfaces to receive WPT treatment, applying a coat of bitumen primer confirming to IS-3384-1986@ 3% per sqm, providing APP based polymeric membrane minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt. not less than 150gms/sqm) laid on primed surface by force application over primed surfaces completed all as specified and directed by Engr-in -Charge. |
| 40 | M&L for hard core of broken stone gauge not exc 63mm deposited speared and leveled in layers not exc 15 cm thick watered and rammed to the surfaces. |
| 41 | M&L for 75 mm thick PCC 1:4 :8 type D-2 (using 40 mm graded stone aggregate) as in sub base as directed by Engr-in-Charge. |
| 42 | M&L for 100 mm thick PCC 1:4 :8 type D-2 (using 40 mm graded stone aggregate) as in sub base as directed by Engr-in-Charge. |
| 43 | M&L for 100 mm thick PCC type B-1 1:2:4 (using 20mm graded stone aggregate) finished even without using extra cement as in floor as directed by Engr-in-Charge. |
| 44 | M&L Sand / Morrum filling under floors or in foundations including watering and consolidation as directed by Engr-in-Charge. |
| 45 | M&L for 75mm thick PCC type C-2 1:3:6 (using 40mm graded stone aggregate) finished even and smooth without using extra cement as in plinth protection. |
| 46 | M&L for rendering 5 mm thick on fair face of concrete surface in CM 1:3 as in ceiling finished even and smooth without using extra cement. |
| 47 | M&L rendering 10mm thick in CM 1 : 6 on fair faces of conc, brick work surface incl finishing the surfaces even and smooth without using extra cement all as specified. |
| 48 | M&L for rendering 15mm thick (10mm thick in CM 1:6 followed by 5 mm thick in CM 1:4) on brick work/concrete surface of walls finished even and smooth without using extra cement with WPC @ 3% by weight of cement. |
| 49 | Supply only water proofing compound confirming to IS complete |
| 50 | M & L for prepartion newly plastered surfaces of walls by applying wall care putty upto 1mm thick and applying two coat of oil emulsion distempher white or coloured over one coat of approved primer complete all specified complete all as specified and directed by EIC. |
| 51 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all specified complete all as specified and directed by EIC. |
| 52 | M&L for preparation of new plastered surfaces of ceiling and applying three coat of white wash |
| 53 | S&F Anodised aluminium frame powder coated for ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 54 | S&F Anodised aluminium frame powder coated ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 55 | S&F sheet glass 4mm thick ordinary quality and glazing with putty in square not exc 0.5 sqm in each pane. |
| 56 | S&F Steel rolling shutters 1 mm thick, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle |
| 57 | M & L for preparation of new or previously un treated steel and iron surfaces over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer or zinc chrome on steel and iron surfaces all as specified and directed. |
| 58 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft loose soil complete |
| 59 | Rolling consolidating formation surface by rolling with 8 to 10 ton roller complete all as specified |
| 60 | M&L PCC 1:2:4 type B2 100 mm thick by using 40 mm graded curshed stone aggregate as in floor finishes complete all as specified including necessary formwork. |
| 61 | M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compound with sealing compound of Grade 'b' material,complete all as specified and as directed by the EIC. Please Enable Macros to View BoQ information |