| 1 | Demolishing cement concrete manually / bymechanical means including disposal of materialwith all lifts and upto 50 m lead etc. complete as perdirection of the Engineer- in-charge:- Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) |
| 2 | Dismantling GS sheet roofing including ridges, hips, valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50m etc. complete as per direction of the Engineer- in-charge. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. - All kinds of soil |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil |
| 5 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --1:3:6 (1 Cement : 3 fine sand : 6 graded well burn tbrick aggregate 20 mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishing and reinforcement-1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 9 | Providing corrugated G.S. sheet roofing includingvertical/curved surface fixed with polymer coated Jor L hooks, bolts and nuts 8 mm diameter withbitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead and including a coatof approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as per direction of Engineer-in-charge. 0.63mm thick with zinc coating not less than 275gm/m2 |
| 10 | Providing wood work in frames of false ceiling,partitions etc. sawn and put up in position : Local Teak Wood |
| 11 | Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes. |
| 12 | Centering shuttering including struttings, propping etc. and removal of form work for: - Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 13 | Centering shuttering including struttings, propping etc. and removal of form work for: - Suspended floors, roofs, landings, balconies and access platform with timber planks |
| 14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | First class brick work in foundation and plinth including cost of all materials as required complete: cement mortar (1:4) |
| 16 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 17 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:- Using flats 30x6mm for diagonal braces and central cross piece. |
| 18 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. all complete as per direction of Engineerin- charge. 40mm thick. |
| 19 | 12 mm cement plaster of mix. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 20 | 15 mm cement plaster on the rough side of single or half brick wall of mix. Cement mortar 1:4 (1 cement : 4 fine sand) |
| 21 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 22 | Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall bemade after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 23 | Finishing with Epoxy paint ( two or more coats) of approved brand and manufacture at all locations prepared and applied as per manufacturer's specification including appropriate priming coat, preparation of surface etc. complete [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. |
| 24 | Finishing with epoxy paint ( one or more coats ) ofapproved brand and manufacture at all locationsprepared and applied as per manufacturer'sspecification on old work including preparation ofsurface etc. as required complete as per direction of the Engineer in charge:- On steel work |
| 25 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 26 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 27 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps |
| 28 | Making connection of G.I. distribution branch with G.I. main following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete as per CPWD specification and direction of the Engineer - in - charge. 25 to 40 mm nominal bore each . |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 15 mm nominal outer dia Pipes. |
| 30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.External work. 25 mm nominal outer dia .Pipes. |
| 31 | Providing and fixing brass bib cock of approved quality.15mm nominal bore |
| 32 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Coupler 110 mm |
| 33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Single socketed pipe - 110 mm OD Please Enable Macros to View BoQ information |