| 1 | S&F in repair for Driver for 60/70 Watts LED street light, High mast light and tower light complete all as specified and directed by Engr in charge. |
| 2 | S&F in repair for Driver for 40/45 Watts LED street light, High mast light and tower light complete all as specified and directed by Engr in charge. |
| 3 | S&F in repair for Driver for 25/30 Watts LED street light, High mast light and tower light complete all as specified and directed by Engr in charge. |
| 4 | Excavation in trenches not exceeding 1.5m in depth deep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified and directed by Engr-in-Charge. |
| 5 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr-in-Charge. (Surplus soil if any shall not be removed but left over the trench) |
| 6 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 7 | Supplying and laying in replacement of double walled corrugated HDPE Pipes of size 40 mm dia as per IS 16205 Anti termite, Anti Rodency and Non flame propagation propety etc for protection of cables complete all as specified and directed |
| 8 | S&F in repair Junction box made out of FRP sheet of size 300x200x115mm , ready made type having aluminium bus bar of capacity 100 Amps 4 Nos with necessary connector , MCB 6 Amps and entry of gland and fixing arrangement to fix the box on plinth/wall by providing MS clamp and nut bolt . Complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply, fixing, connecting and testing in replacement for integral LED flood light luminaries, 100 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to walls/ ceiling etc. complete all as specified and directed by Engr-in-Charge. |
| 10 | Supply, fixing, connecting and testing in replacement for integral LED flood light luminaries, 70 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to walls/ ceiling etc complete all as specified and directed by Engr-in-Charge. |
| 11 | Supply, fixing, connecting and testing in replacement for integral LED Street light fitting, 35 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to walls/ ceiling etc complete all as specified and directed. |
| 12 | M&L for steel tubular swaged pole complete with cast iron/MS iron base plate welded to the bottom of pole finial taper plug bolts, nuts, screws etc as specified type 410 SP-31(9.0 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of silver paint over one coat of red oxide primer to external/exposed surfaces including excavation and earth work in any type of soil, PCC (1:4:8 ) type D-2 for foundation, PCC (1:2:4) type B-1 for pedestal and coping etc complete all as specified and directed. |
| 13 | Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 60 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to pole complete all as specified and directed. |
| 14 | Supply and fixing in repair PVC insulated and PVC sheathed three core Copper conductor of size 1.5 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed by Engr-in-Charge. |
| 15 | Supply and fixing in replacment GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers , Clamps (02 sets) of suitable size complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F in repairs MCB (SPN) 240 volt C curve 10 KA 32/40 Amps capacity IP 20 complete all as specified and directed incl taking down old one. |
| 17 | Supply and fixing in replacement of Automatic Street Light Switch for 3-phase Load of 08 KW using Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS) for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. The Sensor along with suitable Power Contactors with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 20-32 Amps each. Circuit wiring (Copper) of min.10 sq.mm and Auto-Manual selection option (Sensor By-Pass) should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP-66 complete all as specified and directed by Engr-in-Charge. Make : SUDEEP, HANSEL, C&S, SINTEX and L&T |
| 18 | Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 16 Sq mm 4 core complete all as specified and directed by Engr-in-Charge. |
| 19 | Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 10 Sq mm 4 core complete all as specified and directed by Engr-in-Charge. |
| 20 | Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 16 Sq mm 2 core complete all as specified and directed by Engr-in-Charge. |
| 21 | M & L for in replacement of GI tubing light grade 40 mm bore for passing through cables under the floor incl cutting the road and making good afterlaying of GI pipe same as previous surface ,complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed by Engr-in-Charge. |
| 23 | Deduct Credit for Demolished/Dismantled material Rs (-) 1,19,240.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information |