| 1 | M&L for preparation old surfaces of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white/lime wash on walls including cornices, pilasters etc complete all as specified and directed by Engr-in-Charge. |
| 2 | Description all as per item No. 1.00 here in above but on ceiling surfaces. |
| 3 | M&L for preparation old surfaces of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper on walls including cornices, pilasters etc complete all as specified and directed by Engr-in-Charge. |
| 4 | Description all as per item No. 3.00 here in above but on ceiling surfaces. |
| 5 | M&L for preparation old surfaces of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil bound distemper on walls including cornices, pilasters etc ccomplete all as specified and directed by Engr-in-Charge. |
| 6 | Descaription all as per item No. 5.00 here in above but on ceiling surfaces. |
| 7 | M&L for preparation of old painted surfaces of wood or wood based material and applying one coat of synthetic enamel paint on surface of any description over 10cm width or girth complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for preparation of old painted steel (galvanised steel paint) surfaces and applying one coat of synthetic enamel paint on surface of any description over 10cm width or girth complete all as specified and directed by Engr-in-Charge. (Note : Ladders, scaffolding will be provided by Contractor where required) |
| 9 | M&L for preparation of old painted steel (galvanised steel paint) surfaces and applying two coat of synthetic enamel paint on surface of any description over 10cm width or girth complete all as specified and directed by Engr-in-Charge. (Note : Ladders, scaffolding will be provided by Contractor where required) |
| 10 | M&L for one coat of exterior emulsion tera cota on plaster, concrete surface complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for French polishing on old surfaces of any description exc 10cm width or girth in one or more coats including preparation of old wooden surfaces including of wood filler on works with complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for preparing old surfaces of plastered or unplastered surfaces including washing rubbing down and scrapping smoke soot moulds, moss and greasing sports with steel wire brush and applying one coat of cement base paint complete all as specified and directed by Engr-in-Charge. (Note : Ladders, scaffolding will be provided by Contractor where required) |
| 13 | Complete removal of existing surfaces including washing rubbing down and scrapping for applying Two or more coats of 100% Premium acrylic emulsion paint on wall having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. including Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed by Engr-in -Charge. |
| 14 | Taking down cement plaster on brick or stone walls etc.including racking out joints,hacking for key scrubing down with water&receive plaster upto double story height complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for preparing new surfaces of plastered or unplastered and applying two coat of cement base paint over chalk whiting complete all as specified and directed by Engr-in-Charge. (Note : Ladders, scaffolding will be provided by Contractor where required) |
| 18 | M&L for preparation of new plastered surface on wall of any description and applying distempering with two coats distemper oil emulsion distemper complete all as specified and directed by Engr-in-Charge. |
| 19 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering or wall etc complete all as specified and directed by Engr-in-Charge. |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for Complete all as specified and as directed by Engr-in-charge. |
| 21 | S&F Rolled MS Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde E-165), complete all as specified and directed. |
| 22 | S&F Galvanised corrugated mild steel sheeting 0.63mm thick with two corrugation side lap, fixed with coach screws and washers as in roofs, walls etc complete all as directed by Engr-in-Charge. |
| 23 | Fixing only Galvanised corrugated mild steel sheeting 0.63mm thick with two corrugation side lap, fixed with coach screws and washers as in roofs, walls etc complete all as directed by Engr-in-Charge. |
| 24 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and direct by Engineer-in-Charge. |
| 25 | S&F 0.50mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), with grade of zinc coating 275 as complete all as specified and direct by Engineer-in-Charge. |
| 26 | M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and direct by Engineer-in-Charge. |
| 27 | M & L for two coat of synthetic enamel paint of approved tint on steel and iron surfaces of any description over 10 cm width or girth not otherwise described including preparing new zinc(or galvanised) surfaces to receive painting by coating with mordant solution incl washing and cleaning, etc. over a coat of red oxide complete all as specified and directed. |
| 28 | Dismantling of wall and ceiling boards(Fibre, pulp, insulation, etc) or insulation board/slabs/blankets. any thickness, including cover fillets complete.(Note : Taking down carefully old FTL fitting recessed mounted light fittings/ceiling complete with all accessoeies and making necessary electric conection, complete all as specified and directed by Engr-in-Charge. |
| 29 | M & L for 4 mm thick 3 of Plywood, grade BWR, type BB, one side decorative fixed with nails in ceiling complete. |
| 30 | M & L for 4 mm thick 3 Nos of Plywood, grade BWR, type BB, one side decorative fixed with nails in wall complete. |
| 31 | M & L for Plywood 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame in wall portion. All as Specified and directed by Engr-in-Charge. complete |
| 32 | S&F Grid false ceiling GI system powder coated prelude (main runner sec 32x24x0.30x3600 mm, cross tee 25x24x0.30x1200 mm, wall angle 24x24x0.40x3000 mm and including providing and fixing PVC prelaminated aluminium foil backed gypsum tile of size 595x595x9mm fixed in ceiling frame work complete all as specified and directed by Engr in charge. Make:- Armstrong |
| 33 | S&F of coloured PVC designer modular wall cladding 5 to 6 mm thick with air gap, installed with necessary fixing GI channel or frame with end joints on edges (designed, colour patterns as per directed by Engr in charge) The frame work will be fixed to wall using aluminium screws complete all as specified and as directed by Engr in charge. Note: If necessary size of the frame work/ wall paneling will be changed as per site requirement |
| 34 | Dismantling boarding, any description, fixed in any position with nails s complete all as specified and as directed by Engr in charge |
| 35 | M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in levelling course. complete all as specified and directed. |
| 36 | SDC Laminated flooring 8mm thick of any coloured manufactured by Direct pressure laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength complete all as specified and directed by Engineer-in-Charge |
| 37 | Dismantling of timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in unframed work. |
| 38 | M&L plain fillets 2nd class soft wood, square, rectangular or trangular in section, clean sawn, secured with nails or brads,of size exc 13 & n exc 25 sq cm |
| 39 | M&L for 2 nd class soft wood not exc 6 sqcm moulding as in cornices ,picture vrail complete all as specified |
| 40 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 41 | M & L for coloured non-skid ceramic tiles 7 to 8 mm(square/rectangular) rea of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc 15 mm thick cement mortar screed bed or bedding layer in CM 1:6 complete all as specified and directed by Engr-in-charge. |
| 42 | M&L for colour glazed ceramic tiles in vertical surface 450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat of CM 1:4. |
| 43 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, light fitting cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 44 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, light fitting cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. Please Enable Macros to View BoQ information |