Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Chief Engineer Shillong Zone NAME OF WORK: ADDITION/ALTERATION AND SPECIAL REPAIRS TO EXISTING SWIMMING POOL AT ARC UNDER GE SHILLONG. Contract No: CESZ/SHL/ OF 2025-2026 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | SCHEDULE A PART (IA) LUMPSUM PRICE TO BE QUOTED BY CONTRACTOR |
| 4 | Construction of \\"PLANT ROOM\\", single storey, in RCC framed structure, water proofing treatment to roof, seismic consideration of Zone \\"V\\", with all fittings and fixtures, including ramps, steps, platform, plinth protection, verandah, rolling shutters, complete all as specified and as shown on drawings. |
| 5 | Construction of \\"BALANCING TANK\\" for swimming pool (capcity 42,000 Ltrs), RCC framed structured, seismic consideration of Zone 'V', with all fitttings and fixtures, complete all as specified and as shown on drawings. |
| 6 | SCHEDULE A PART (I) PREPRICED BUILDING SSR |
| 7 | Lumpsum price worked out by the tenderer for REPAIR TO SWIMMING POOL as listed in Schedule ‘A’ Part-I(B) |
| 8 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-I(C) |
| 9 | Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENT & EARTHWORK as listed in Schedule ‘A’ Part-II |
| 10 | Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III |
| 11 | Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV |
| 12 | Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-V |
| 13 | Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-V(A) |
| 14 | SCHEDULE 'A' SEC-VI (MISCELLANEOUS ITEMS) NOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS \\"RS 0.00\\" UNDER COL. 5 SIGNIFIES THIS FACT ONLY. |
| 15 | M & L for Glass Moasic Tiles 200x 200x5mm in floor laid over and including 20mm thick (1:6) screed bed jointed pointed with coloured cement to match the tiles including epoxy grouting and water proofing adhesive, complete all as specified and a directed. |
| 16 | M & L Glass Moasic Tile 200x200x5mm thick in wall, skirting, set and jointed in neat cement slurry and pointed in white or colour ceement to match the tiles including epoxy grouting and water proofing adhesive, complete all as specified and as directed as per manufacturing instructions. |
| 17 | INTERNAL ELECTRIFICATION: Supply and installation on roof of 1.2HP Pressure Booster Pump with 60L Tank Capacity with provision of suitable size shed cover including PCC/angle iron Work complete with electrical connection all as specified and directed by Engr In charge . Make : Grundfos Model No:CMB 5-46 60L |
| 18 | Supply and Fixing 5.0 KVA Inverter with Tubular Inverter Battery (150Ah) complete all as specified and directed by Engr in Charge |
| 19 | FILTRATION PLANT:Design, Supply, Installation, Testing and Commissioning of Factory fabricated, vertical type Multi Grade Sand Filter- Vessel Dia -2200 mm (min), Vessel HOS -2175 mm (min), Filtration Flow Rate- 55 m³/Hr (max.), Designed Thickness -10mm, Shell Thickness -8mm , Made of MS internal epoxy painted with collector arms and distributers made MS heavy pipe, frontal piping with 150 mm valve for filtration , backwash & rinse process . working pressure 2.5 Kg/cm2 , desgn pressure - 3.5 kg/cm2 , Test Pressure 5.0 Kg/cm2 confirm to IS-2062. Filter Media Details along with minimum shall be as per details given below [i] Quart Z Pebbles of 1\\" to 3/4\\" not less than 100 mm thick layer[ii] Quart Z Pebbles of 3/4\\" to 1/2\\" not less than 100 mm thick layer[iii] Quart Z Pebbles of 1/2\\" to 1/4\\" not less than 100 mm thick layer[iv] Quart Z Pebbles of 1/4\\" to 1/10\\" not less than 100 mm thick layer[v] Quart silica sand of assorted sizes not less than 900 mm thick layer [vi] Back wash arragement shall be made to facilitate the back washing system[vii] Pressure transmitter -02 Nos alongwith suitable instrumentation to provide backwash alarm / display[viii] Air vent system with 25 mm pipe with gun metal valve[ix] Pressure relief valve ,nut and bolt and gasket for filter [x] Suitable size of main hole and hand hole.Filter Flow Rate: 55 M³/Hr.Filtration Velocity: 15 M³/Hr/M² (max.)Diameter: 2200 mmDesign details, scope of work, detailed technical specification shall be as per Annexure 'A'. |
| 20 | Supply, Installation, Testing and Commissioning of identical centrifugal filtration/backwash pumps,Horizontal end‑suction, 60 m³/h @ 24 m head, flooded suction IE3 motors, VFD‑ready, CI body, with pre filter in SS 316, with matching connection size including vibration eliminating rubber bellows , Bronze Impeller in, Motor shaft in Stainless steel AISI 316 , Mechanical seal,(SiC/SiC/Viton) suitable for chlorinated pool water; IE3 TEFC motor; VFD‑rated; accessories: suction/discharge pressure gauges, vibration pads, flexible connectors, isolation valves, NRVs; installed on common suction (DN200), service header (DN200) and backwash header (DN200) with motorized changeover per pump. Motor -1450 RPM, Asynchronous,Four Poles, Continuous Opeartion F class insulation, protection IP-55, Operating voltage - 380V/ 3 phase, 50HZ . (2 W + 1SB )Flow Rate: 60 m3/Hr Head: 20-25 meterOperating modes: PEAK 110 m³/h (2 pumps, 2 filters), NON‑PEAK 36–38 m³/h (1 pump, 1 filter), BACKWASH 70 m³/h + air scour (one filter at a time), set points via VFD.Valving: Add motorized service inlet/outlet valves on each MGPSF; automatic filter rotation in non‑peak.Controls: Flow‑setpoint (VFD), filter DP alarms, interlocked backwash logic, time‑of‑day scheduler.(Note : 1. Pump shall be mounted on a concrete Foundation Projecting at least 15 cm above finished floor level 2. Detailed design, operation and control shall be as per Annexure 'A' enclosed) |
| 21 | Design, supply, installation, testing and commissioning of Indoor type integrated VFD starter-cum-PLC motor control panel for pool filtration and backwash by operating 3 nos. filtration pumps (each ~60 m³/h, 2D+1S) and 1 no. air blower (≈285 m³/h @ 0.5 bar(g), 7.5 kW), including all internal protections, wiring, programming and HMI as per Annexure (design/logic/mode details). Backwash valves shall be manual; panel provides interlocks, timers and prompts.Technical Specs (panel only):(a) Power: 415 V, 3-phase, 50 Hz; Main MCCB 4P ≥125 A; Al /Cu busbars ≥200 A, earth bar.(b) Drives: 3× VFD ≥11 kW (one per pump) with input choke & bypass contactor; 1× VFD ≥7.5 kW for blower.(c) Control: PLC (min. IO as per Annexure), 7″ HMI, 24 VDC SMPS, Class-II SPD, selector switches HOA per motor, estop chain, door interlock.(d) Metering/Indication: V/A/Hz/kW on incomer, run/healthy/trip lamps, alarm buzzer.(e) Enclosure: Floor-standing IP54 CRCA, powder-coated, cooling fans with filters, labeled terminals, 20% spare space.(f) Functions (as per Annexure): (i) Peak filtration: 2 pumps on VFD to hold Q≈110 m³/h, 1 standby with auto rotation. (ii) Non-peak: 1 pump on VFD to hold Q≈36–38 m³/h (one filter in service). (iii) Backwash 2 Pumps in parallel in VFD to hold Q ≈ 70 m³/h (one filter at a time) (iv) Backwash assist: step timers for air-only → air + water → water-only, interlocks to prevent unsafe starts; blower on VFD. (v) Trips/alarms for low suction, high discharge, VFD fault, motor thermistor; event log. |
| 22 | (g) Documentation & Tests: GA/SLD/wiring/IO list, cause-&-effect, HMI screenshots, FAT & SAT, O&M manuals, training.Inclusions: Panel internal components, control wiring, programming, factory testing, delivery, installation on plinth, termination up to panel glands.Exclusions (measured elsewhere): Field instruments/valves, external power & control cables beyond panel, civil works, earthing grid, LT incomer.Note: (i) Bidder’s rate shall be all-inclusive for the above scope. (ii) Detailed sequence/IO/mode logic shall be as per Annexure “Control Philosophy & P&ID”.Makes (or equivalent):• Switchgear: Schneider/L&T/Siemens/ABB or equivalent• VFD: Danfoss/ABB/Schneider/Yaskawa or equivalent• PLC/HMI: Siemens/Schneider/ABB or equivalent |
| 23 | Supply, install, test and commisioning of air‑scour blower, MGPSF backwash: Type: oil free positive displacement tri lobe Roots blower, Q = 235m³/h @ 0.5bar(g), motor 7.0kW, IE3, TEFC, VFD‑ready; skid‑mounted with inlet filter, inlet & discharge silencers, NRV, PRV 0.6bar(g), pressure gauge, flexible connectors, baseframe and belt guard; paint system epoxy. Scope includes common 80NB header, 65–80NB branch set with motorized butterfly valve and NRV, instruments, and all supports. (Duty: one filter at a time; 1W+1S arrangement). Air‑rate basis: 55–65m³/h·m² for 5–7minAir (Note : 1. Pump shall be mounted on a concrete Foundation Projecting at least 15 cm above finished floor level 2. Detailed design, operation and control shall be as per Annexure 'A' enclosed. |
| 24 | Hybrid Disinfection System (Ozonation + Automatic Variable Chlorination + pH dosing): Design, supply, installation, testing and commissioning of a complete ozone package located upstream of MGPSF including PSA oxygen system, 50 g/h oxygen‑fed ozone generator (turndown ≥20%), sidestream pump with VFD, venturi injector, 4–4.5 m³ baffled contactor (T10 ≥ 2.0 min at peak), degas separator, catalytic off‑gas destructor, static mixer on return to filter inlet manifold. Automatic variable calcium hypochlorite dosing system (1D+1S, 1000 L tank, agitator, VFD control), and pH dosing system; complete with flow / dissolved‑ozone analyzers (post‑contactor and on filter inlet manifold with trip at 0.05–0.10 mg/L), ORP (pre‑pool), chlorine + pH analyzer (pool return), PLC/HMI with interlocks, ambient O₃ detector, valves/NRVs/back‑pressure valve, ozone‑rated piping in PVDF/PTFE/Titanium with FRP‑lined vessels as applicable, supports, cabling from local JB to panel. commissioning, operator training, O&M manuals and 24-month warranty; all conforming to IS:8417, NSF/CE, ISO 9001 standardsPerformance Guarantees:• Dissolved ozone ≥0.30 mg/L at peak with ≥85% mass transfer• Free chlorine maintained at 0.4–0.8 mg/L (±0.1 mg/L)• pH maintained at 7.2–7.6 (±0.2)• Contact time T10 ≥ 2.0 minutes• Full compliance with ozone safety regulationsMaterials and compatibility: All ozone‑wetted water/gas paths shall be PVDF/PTFE/Titanium/EPDM‑Viton (no stainless/uPVC). Stainless steel may be used in non‑ozonated sections only (downstream of MGPSF). |
| 25 | Design, supply, installation, testing and commissioning of ozone-rated plumbing system for the complete ozonation package of the swimming pool disinfection plant, including all interconnecting pipelines, fittings, valves and supports from the circulation pump discharge to the ozone sidestream loop, venturi injector, baffled contactor, degas assembly, catalytic off-gas destructor, and return to filter inlet manifold, as per technical specifications and design drawings.Scope:(a) All ozone-wetted piping in PVDF/PTFE/Titanium/FRP-lined MS (as per specs).(b) Side-stream loop (≈25% of flow) with VFD-controlled pump, venturi ejector (PVDF/PTFE), static mixer (SS316L/PP/FRP).(c) Interconnecting suction & delivery headers, valves, NRVs, isolation valves, back-pressure valves, pulsation dampers, injection quills.(d) Ozone contactor (4–4.5 m³) connections, degas dome outlet to off-gas destructor, condensate drain.(e) Analyzer tapping points (dissolved ozone, ORP, chlorine, pH) as indicated.(f) Supports, anchor blocks, flanges, gaskets (PTFE/Viton only), painting/coating for external protection.(g) Testing (hydrotest, leak test), flushing, commissioning and handing over with O&M manuals.(h) Materials (ozone-wetted): PVDF/PTFE/EPDM/Titanium. Avoid uPVC and SS304/316 in ozonated paths. |
| 26 | Design, supply, installation, testing & commissioning of the plumbing system for the automatic variable chlorine dosing (Cal-Hypo 65%) and pH correction (CO₂ or acid) within the plant room, complete with all interconnections, fittings, valves, injection assemblies, and safety accessories, ready for operation.Plumbing scope includes :(a) Chemical storage & transfer: HDPE day tanks (1000L tank for agitator with level switches & venting), suction strainers, anti-vortex foot valves, calibration column (1 L), suction/discharge manifolds with isolation.(b) Dosing lines: PVDF/PTFE (DN15–DN20) from pumps to injection points with containment/drip trays, NRVs, back-pressure valves, pressure relief, pulsation dampers, pressure gauges, flushing tees, sample cocks.(c) Injection assemblies: Corrosion-resistant injection quills with NRV for chlorine and acid lines; spool piece and static mixer on clean-return header (where specified).(d) pH system optioning:(d)(i) CO₂ option: cylinder manifold with dual-stage regulators, gas non-return, flexible pigtails, diffuser/mixer assembly, copper/SS gas piping within plant room, signage & chain-restraints.(d)(ii) Acid option: HDPE day tank (1×200–300 L), PVDF/PTFE dosing line with full valve set & injection quill (as above). |
| 27 | (e) Analyzer tapping points (provisions only): threaded/flanged sockets for free-Cl₂, pH, and sample take-off loop on pool-return line.(f) Supports & finishes: Pipe supports/clamps, tags, PTFE gaskets, external protective coating, hydrotest/flush and commissioning.Materials:(a) Dosing/wet chem lines: PVDF/PTFE/PP-H, EPDM/Viton seals; HDPE tanks.(b) CO₂ gas lines: annealed copper/SS with approved fittings.(c) Headers/spools: MSRL/SS (non-chlorinated sections)Note for 4(a), 4(b) & 4(c) : (i) Detailed design, scope of work and technical specification shall be as per Annexure 'B'(ii) Quoted rates shall deemed to be inclusive of all fittings, small materials, supports, testing & commissioning for the dosing plumbing within plant room. |
| 28 | Design,Supply, installation, testing and commisioning of Electro chlorination based system of treating 100 cumtr / Hr swimming Pool water suitable for capacity 405 cum swimming pool (Hydro-dis system or eq) including UPVC piping control panel complete all as specified and directed by Engr-in-Charge.( Note : Tenderer shall submit OEM certified design details & efficacy of process along with connected documents for approval of Accepting Officer) |
| 29 | Supply, Installation, Testing and Commissioning of Drain chamber ø200mm, depth 300mm, HDPE/PP gully (circular) with DN110 inlet/outlet sockets, straight-through (no trap), removable sediment basket, SS316 pedestrian-duty cover/grating (A15), includes cutting, settling levels, sealing and testing with water tight joints and anti-slip cover. |
| 30 | Supply, Installation, Testing and Commissioning of Floor inlet/diffuser, 32mm (flush type), rated 5.7m3/hr, UV stabilized ABS or bronze bldy with SS316 trim, 32mm spigot/thread, O-ring seal, includes fittings elbow, socket, solvent all confirming EN-13451 (Pool circulation fittings, and connect via DN63/75 branches with branch isolation valve. |
| 31 | Supply, Installation, Testing and Commissioning of 250-300 mm wide Overflow Grating made of UV Stabilized PP in white color.Width 250-300 mm Thickness 22 mm matching the width of over-flow drain |
| 32 | Supply, Installation, Testing and Commissioning of Stainless Steel 304 ladders, width: 500mm, handrails dia 42 mm stainless steel, non-slip steps provided with anchoring Socket for 3 steps Ladder . |
| 33 | Supply, Installation, Testing and Commissioning of Stainless Steel 304 ladders, width: 500mm, handrails dia 42 mm stainless steel, non-slip steps provided with anchoring Socket for 4 steps Ladder . |
| 34 | Supply, Installation, Testing and Commissioning of Hand Rail, 1.2 meter long in Stainless Steel 304. |
| 35 | Supply, Installation, Testing and Commissioning Anodised Extruded Stainless Steel Vacuum Head -900 MM SS fixed with clip type connection 1-1/2\\" |
| 36 | Supply, Installation, Testing and Commissioning Reinforced telescopic Handle 3.6-7.2 mtr long |
| 37 | Supply, Installation, Testing and Commissioning Floating suction hose ,made of polyethyene blue color 40 mm (1-1/2\\") 30 mtrs long. |
| 38 | Supply, Installation, Testing and Commissioning Water surface skimmer clip type |
| 39 | Supply, Installation, Testing and Commissioning Curved brush clip type. |
| 40 | Supply, Installation, Testing and Commissioning Test kit for pH and chlorine |
| 41 | Supply, Installation, Testing and Commissioning Algae Brush SS Bristles. |
| 42 | Supply, Installation, Testing and Commissioning Straight Brush clip type. |
| 43 | Supply of Trolley mounted suction sweeper kit, (i)Trolly made of MS painted with wheels for smooth movement arrount the deck, (ii) Including self priming, non-clogTrolley mounted suction SP Series pump capacity 2 HP (Make: Kirloskar) including (iii) Nylon rope & (iv) starter with sutaible size and length of submersible cable complete in all respect (V) 10 Nos. of float complete to support the hose, clips for connection . |
| 44 | Supply of Life Bouy |
| 45 | Supply of Life Bouy Hook |
| 46 | Supply of TCCA 90 pool disinfection chemical |
| 47 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes DN 63mm dia (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 48 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes DN 110 mm dia (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 49 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes DN 150 mm dia (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 50 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes DN 200 mm dia (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 51 | Supply, Installation, Testing and Commissioning of SCADA ready actuated Motorised butterfly / Sluice valves for swimming pool system, with open area installation, line pressure maximum 7 bars, ends-wafer, duty- on/off, 230V AC/24V DC, IP67 enclsoure, insulation class-F complete with travel switch and torque switch of size 200mm NB including all necessaories for its complete operation. |
| 52 | Supply, Installation, Testing and Commissioning of CI dual plate Check Valve (PN 20) 200mm dia complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes. |
| 53 | Supply, Installation, Testing and Commissioning of following sizes of heavy duty PVC puddle flanges Sch40, for 110 mm dia, fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the Swimming pool walls & Slab (As required). |
| 54 | Supply, Installation, Testing and Commissioning of following sizes of heavy duty PVC puddle flanges Sch40, for 160 mm dia, fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the Swimming pool walls & Slab (As required). |
| 55 | Supply, Installation, Testing and Commissioning of following sizes of heavy duty PVC puddle flanges Sch40, for 200 mm dia, fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the Swimming pool walls & Slab (As required). |
| 56 | Design, Supply, Installation, Testing & Commissioning of Swimming Pool Main plumbing system complete with suction header, delivery header, backwash header, Air line header, filter line header, tie connection line for Heat pump, Automatic variable Chlorine Dozing, Ozonation, & pH dosing system, complete system for the swimming pool circulation plant (capacity 110 m³/h, 4-hour turnover), including but not limited to:(a) Suction header DN200 from balancing tank with DN150 pump branches (2W+1S pumps), duplex basket strainers, isolation valves.(b) Pump discharge DN125 manifolds with NRV, isolation valves, gauges.(c) Common discharge header DN200 with flowmeter and pressure tappings. (d) Backwash header DN150 with flowmeter and pressure tappings. |
| 57 | (e) Ozone side-stream tie-ins DN80/100 with valves, NRV, strainers.(f) Filter inlet/outlet DN150 headers (2 MGPSF filters) with isolation & NRVs.(g) Filtered water header DN200 complete with tie-ins.(h) Heat pump bypass manifold DN200 with Y-strainer, isolation & balancing valves.(i) Chemical dosing injection quills (pH & chlorine) with DN200 static mixers.(j) Valves, gauges, air release, drains, flexible connectors at appropriate points.(k) Supports, anchors, identification, erection, flushing, hydrotest & commissioning.Note : i) Detailed tech specification & design condition shall be all as per annexure 'A'.(ii) Quoted rate shall deemed to be inclusive of all plumbing work incl all accessories, manual/motorised valves, non return valves & instrumentation & sensors from balancing tank outlet suction point to filtration plant to main return / filter line towards swimming pool till outside plant room plinth |
| 58 | Supply, laying, testing and commissioning of following size PVC insulated sheathed copper conductor 1100 V grade, 4 x 6 Sqmm unarmoured cable with required size of sleeves complete as required. |
| 59 | Supply, laying, testing and commissioning of following size PVC insulated sheathed copper conductor 1100 V grade, 2 x 4 Sqmm unarmoured cable with required size of sleeves complete as required. |
| 60 | Supply, laying, testing and commissioning of following size PVC insulated sheathed copper conductor 1100 V grade, 2 x 2.5 Sqmm unarmoured cable with required size of sleeves complete as required. |
| 61 | Supply, laying, testing and commissioning of following Heavy PVC insulated sheathed copper conductor flexible multistand wire 1.5 Sqmm single core FRSL multistranded flexible coppler cable, complete all as specified and directed. |
| 62 | Supply, laying, testing and commissioning of following Heavy PVC insulated sheathed copper conductor flexible multistand wire 2.5 Sqmm single core FRSL multistranded flexible coppler cable, complete all as specified and directed. |
| 63 | Supply, laying, testing and commissioning of following Heavy PVC insulated sheathed copper conductor flexible multistand wire 6 Sqmm 3 core FRSL multistranded flexible coppler cable, complete all as specified and as required. |
| 64 | Supply, laying, testing and commissioning of following Heavy PVC insulated sheathed copper conductor flexible multistand wire 6 Sqmm 4 core FRSL multistranded flexible coppler cable, complete all as specified and as required. |
| 65 | Supply, laying, testing and commissioning of following Heavy PVC insulated sheathed copper conductor flexible multistand wire 10 Sqmm 4 core FRSL multistranded flexible coppler cable, complete all as specified and as required. |
| 66 | Supply, laying, testing and commissioning of HO7RN-F a heavy duty flexible rubber cable 450/750V rating, EPR-insulated, 6 Sqmm 2 core cable (from Transformer secondary to Deck JB) chloroprene/neoprene-sheathed, fine stranded Copper conductor cable for swimming pool application alongwith PVC-U conduit and its fixing accessories complete as required. |
| 67 | Supply, laying, testing and commissioning of HO7RN-F a heavy duty flexible rubber cable 450/750V rating, EPR-insulated, 2.5 Sqmm 2 core cable (from Deck JB to Pool light luminaire) chloroprene/neoprene-sheathed, fine stranded Copper conductor cable for swimming pool application alongwith PVC-U conduit and its fixing accessories complete as required. |
| 68 | Supply, laying, testing and commissioning of 25 mm size Heavy PVC electrical conduit with duct,saddles, lugs complete as required. |
| 69 | Supply, installation, testing and commissioning of GI perforated cable tray of size 150 mm wide, complete all as specified and as directed. |
| 70 | Supply, installation, testing and commissioning of GI perforated cable tray of size 200 mm wide, complete all as specified and as directed. |
| 71 | Supply, installation, testing and commissioning of GI perforated cable tray of size 300 mm wide, complete all as specified and as directed. |
| 72 | Supply, installation, testing and commissioning of G.I Earthing Wire-8 SWG |
| 73 | Supply, laying, connection and testing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 20x3mm copper strip as directed |
| 74 | Supply, installation, testing and commissioning of MS Structure work (MS Angle, Fastners, Tie Rods) for pipe support. |
| 75 | Supply, installation, testing and commissioning of Under water swimming pool LED luminaire of specifications:-(a) 30-36W, 24V AC, ≥3000lm, 4000K, 110-120° beam, CRI ≥ 80(b) 24V, AC SELV, Class-III double-insulated(c) IP68, IK10, SS316L front + tempered glass(d) Niche type with rear conduit entry, silicone gaskets, captive screws(e) Each with 5m factory-moulded cable tail, HO7RN-F or equivalent(f) Wall mounted type with built-in driver, including push in connector in 4 pole, including all fixing arrangement in swimming pool wall to accommodate pool light. |
| 76 | Supply, install, testing & commissioning of Swimming Pool lighting panel, IP54 protection, floor-standing of suitable size with sufficient spacing for fixing of breakers and cable termination, suitable for 415V, 3 phase, 4-wire, 50 Hz, AC supply system, totally enclosed, dust, weather & vermin proof, 2.0mm thick for outer shell and 2 mm thick for inner shell having TPN copper busbars epoxy sleeved, colour coded of rating 1.5 times minimum that of controlling MCBs supported on SMC insulators with short-circuit withstand capacity ≥16 kA/1s, bottom base channel of MS section not less than 50mm x 50mm x 6mm thick, entire panel shall have a common copper earth bar of suitable size at the rear with 2Nos earth earth stud, solid connection from main bus bars to switchgears with required size of copper bus bars and control wiring with minimum 1.5sqmm FRLSZH, cable alleys, cable gland plates in two half including digital Multi-function meter to measure voltage, current, PF, kWH, kVAH,etc (Make: Secure/L&T/Schneider), Type-2 SPD and general construction confirming to IS:8623/93 and suitably mounted on wall with all fixing accessories complete with following detailed specification and controls:- |
| 77 | Instrumentation details:-(a) Control MCB 6A, SP, 10kA - 01 No(b) Timer 24H mounted on DIN rail, 230V - 01 No(c) HOA Selector switch 3 position - 01 No(d) Pushbuttons and LED indicators - Step-1, Step-2, Power & RCD trip - 01 set(e) Neutral & Earth busbar : Copper rating 125A (with connecting studs)(f) FRLSH 4.0 sqmm x 2C wire from RCBO to Transformer primary(g) Engraved tags on wiring for identification, cable lugs, saddles and other necessary accessories as required for complete job. |
| 78 | Incoming :-(a) MCCB 63A, 4P, 25kA, Type-C, fixed thermal & fixed magnetic release - 01No(b) Surge suppressor Type-2, 3P+N, 275V, Imax 40kA - 01 No |
| 79 | Outgoing :-(a) RCBO 10A, 1P+N, 230V, 30mA with short circuit capacity & Over-load protection- 05 No (4W + 1S)(b) Contactor AC-1 16A, 230V coil - 05 No (4W + 1S)(c) MCB 16A, DP, 10kA, Type-D - 05 No (Transformer secondary) (4W + 1S)(d) Pool light Isolation Transformer, resin filled 1.0 kVA, 230/24V, AC, isolating, IP54 - 03 No (2W + 1S) (Diversity not allowed & size for continuous & split across 4 circuits)(e) Pool light Isolation Transformer, resin filled 0.75 kVA, 230/24V, AC, isolating, IP54 - 02 No (2W) (Diversity not allowed & size for continuous & & split across 4 circuits) Note : The cost of material, labour and tools required for civil opening, core cutting, making good, non-shrink grout around niches, water tight conduiting in entire swimming pool area and making good the disturbed surfaces is deemed to be included in the above quoted rate. |
| 80 | Supply, Installation, testing and commissioning of resin/gel-potted deck junction box of following specifications:-(a) Suitable for 24V AC SELV circuits, size ≥ 160x16 x90mm for upto 3-4 luminaires & ≥200x200x100mm for upto 5-6 luminaires, SS316 hardware, fixed on SS316 bracket or wall with SS316 captive screws, internal M6 earth stud(b) 6xM20 entries with glands and blanks, internal terminals (2x6 sqmm loop + up to 4x2.5 sqmm lamp pairs)(c) Location : Mounted ≥ 1.2m from water edge and ≥ 0.3m above finished deck, cable entry from below/side(d) Enclosure : material UV stabilized glass-reinforced PC/PA or SS316, lid with continuous silicone gasket(e) Protection : IP68 (immersion ≥5m for 72h) and IK08minimum(f) Cable entries & glands : 4-8 threaded entries, M20(min) with IP68 glands & blanks, Glands PA66 or nickel-plated brass with neoprene seals, clamping ø6-12mm, one dedicated gland per luminaire tail, seperate glands for feeder In and feeder OUT (looping). |
| 81 | Supply, Installation, testing and commissioning of Starting platform/starting blocks adjustable platform in polyester and fiberglass with non-slip finish of size 500 mm x 500 mm x 400 mm ht with frame in SS 304 polished finish. |
| 82 | Supply, Installation, testing and commissioning of Anchor Fastener , Anchor Bracket SS 304 |
| 83 | M & L for Earthing complete with galvanized steel earth plate 60 cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less less than 1.5 mtr filled around with layer of charcoal dust and salt and connected to GI Strip 32x6mm as earth lead by means of bolt, nut and check nuts and washers of galvanized iron or steel and thimble and other ends of the earth strip connected to main switch board and protected by galvanized iron pipe light grade 40mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, pcc 1:3:6 in chambers RCC 1:2:4 in pit cover reinforced with 8 mm dia deformed bars 15cm center to center both ways all as directed by Engr-In-Charge, complete all as shown in electric plate No 3 of MES Sch Part I of 2009 etc including necessary earth and disposal of surplus soil complete and testing all as specified and directed. NOTE :- (i) The unit rate shall be include protection pipe, GI water pipe, wire mesh, funnel excavation, RCC pit cover, 32mm x 6mm GI strips from the earth plate upto 7.5 Mtr length. |
| 84 | M & L for earth continuity conductor, aluminium strip of size 25x3mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing complete all as specified and as directed by Engineer in Charge. |
| 85 | Supply, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type LT Panel indoor type of appropriate size and fabricated from 2.0 mm thick CRCA sheet steel with necessary MS angle iron frame work (50X50X6mm), weather proof, vermin proof, suitable rating copper bus bar chamber for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labeling , cable alley suitable for termination of cables including supply and fixing of following switchgear and accessories in the panel complete as required size. The panel should be IP-54 protection including necessary foundation for mounting all as specified and directed by Enginer in charge. (Main LT panel indoor)Instrumentation :-(i) Digital Voltmeter (0-500 Volts) with selector switch -01 No(ii) Digital Ampere meter (0-250 A) with selector switch - 01 No(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) MCB 6 Amp SP - 01 No |
| 86 | INCOMING: (i) MCCB 4 pole 160 Amp 25 KA 415V with microprocessor release setting conform to IS/IEC 60947-2 & adjustable overload From .1-1.0 X In Adjustable Short Circuit from 1.5-8 X Ir with selectable time dealy,fault protection from 10% -50 % of li,Adjustable neutral overload protection available 50% to 150 % of Ir - 01 No. OUTGOING: (i) MCCB 4 pole 100 Amp 16 kA 415V, fixed thermal & fixed magnetic release - 02 Nos (01W + 01SB) . (ii) MCCB 4 pole 63 Amp 16 kA 415V, fixed thermal & fixed magnetic release - 01 No. (iii) MCB TP 32A, 16kA - 04 Nos. |
| 87 | Supply & laying and testing cable PVC insulated ,screened, PVC bedded, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core including fixing on wall/roof/cable tray as per site requirement including its fixing accessories complete all as specified and as directed by Engineer In Charge. |
| 88 | Supply, install, teasting and commissioning of Smart energy meter (IS-16444), AC whole current, three phase, 4 wire, CT operated Smart Energy meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site condition and as per design consideration of AMI implementing agaency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangemenrs of suitable size as per the requirement of OEM of electric meter. The cost of meter would include the supply of current transformer, rated burden 15VA, accuracy class 0.5S, frequency 50Hz and voltage class 660V, effectively earthed and CT ratio suitable as (60/5 to 1000/5) completecomplete all as specified and as directed. |
| 89 | Design, Supply, Installation, Testing and Commissioning of Factory Assembled Air‑Source Inverter Pool Heat Pump, Low‑Ambient, R‑32/R‑410A, scroll (vapour‑injection),microprocessor controls, weather‑proof; Capacity minimum 60 kW @ Air 7 °C, Water 27→29 °C; COP ≥4.0 at 7 °C, ≥5.0 at 15 °C; EC axial fans; sound ≤60 dB(A) @10 m; BMS (Modbus/BACnet) run on 415Volt, 50 Hz AC complete all as specified below: Make : York, Carrier, Trane or eq |
| 90 | (a) SITC of Brand New Air-Cooled Inverter Heat Pump Units complete with Single/Multiple Scroll compressors, Evaporator, air-cooled condenser, Control panel etc. The Heat Pump will be charged with R410A Refrigerant. The drive motor suitable for 415V +/-15%, 3 phase, 50 Hz.(b)The refrigerant circuit shall include: a discharge service ball type isolation valve, dual high side pressure relief valves, liquid line shutoff valve with charging port, dual low side pressure relief valves, solenoid valve, sight glass with moisture indicator, electronic expansion valves, and flexible,closed-cell foam insulated suction line and suction pressure transducer, refrigerant receiver,discharge liquid separator and R410A refrigerant.(c) Modular design with an ability to mix and match combinations upto desired Nos connected Heat Pumps. They can operate in Master and slave configuration mode or can operate separately. |
| 91 | (d) The Chiller Heat Pump evaporator should beTitanium Plate Heat Exchanger, approach ≤1 K, design pressure ≥10 bar,, with direct-expansion and counter-flows. The heat exchange surface is configured so as to maximize the exchange coefficient with minimal load losses. capable of refrigerant working pressure of 650 psig and liquid side pressure of 150 psig. Input and output connections shall be fitted with air bleeder and draining valves. The covering in closed-cell neoprene sponge prevents the formation of condensation and reduces thermal wastage.The condenser side Fin and Tube heat exchanger shall have hydrophilic coated Aluminum fins with copper tubes(anti corrosive). |
| 92 | (e) Air-cooled Condenser with integrated fin and tube coils with inner grooved copper tubes and expanded into aluminium fins and complete with sub cooler and top discharge air circulators using EC(Electronically Commutated) axial flow fans with IP 55 protection for outdoor duty , U shaped condenser coil guard etc. permanently-lubricated ball bearings. Brushless commutation and minimum self-heating. |
| 93 | (f) The Compressor motor shall be Inverter driven and with protection for under voltage, over load,earth fault and single phasing, Integrated thermal protection, Speed control with inverter,Inverter start-up, Power factor correction condensers, Oil valve and by-pass line, Anti-vibration supports etc. It should have, Hot water temperature sensors, water flow sensors / flow switch etc.Compressor Motor overloads capable of monitoring compressor motor current. Provides extra protection against compressor reverse rotation, phase-loss and phase-imbalance. Motor overheat protection will be provided to ensure the motor reliability. |
| 94 | (g) Micro-processor based controls( safety interlocks that monitor pressure, temp., current,voltage, oil and refrigernat etc) with Touch screen display in English for all operating parameters such as supply voltage, frequency, load current, Hot water inlet, Hot water outlet, temperature parameters, operating pressures, input power etc. h) Wired controller LCD Touch Screen Panel with LED backlighting for enhanced control of operation at single point. Head - 20 mtrs (1W1- I SB) |
| 95 | Design, Supply, install, testing and commissioning of Hot water circulation Secondary Pumps (VFD), ≈26–28 m³/h @ 18–22 m head, IP55, IE3/IE4 motor, with suction diffuser/Y‑strainer, NRV, isolation valves, vibro‑pads (For Circulating Hot water between Swimming Pool and PHE. (Secondary circuit) (1 W+1 SB) |
| 96 | Design, Supply, install, testing and commissioning of Power & Control Panel (PCP) for heat pump system including hot water circulation secondary pumpsSystem: 415 V, 3 phase, 4 wire + PE, 50 Hz., Estimated connected load, Heat Pump Unit (HPU) – 60 kW thermal each; electrical ≈ 15–20 kW/unit at winter COP 3–4 → FLA ≈ 30–35 A/unit, Secondary Pump motors (assumed) 5.5 kW each (VFD driven) → FLA ≈ 11–12 A each, Panel aux/controls/fans/heaters ≈ 1.5 kW, Total ≈ 53 kW → Ib ≈ 82 A at PF 0.9, Short circuit rating (SCCR): ≥35 kA/1 s (recommend 50 kA if available from OEM for future proofing), Installation: Indoor plant room (IP54) or weatherproof kiosk (IP55) if outdoors, stainless hardware, topicalization for Shillong humidity.(I) Panel construction(a) Form of separation: Form 2b minimum (Form 3b preferred—separate outgoing compartments).(b) Enclosure: CRCA steel 2.0 mm, epoxy polyester RAL7035, base plinth 100 mm, gasketed doors, padlockable. |
| 97 | (c) Busbars: Aluminium, 3P+N, 200 A continuous rating, SCCR ≥35 kA/1 s; epoxy sleeved; colour coded; 2×P.E. bars.(d) Cooling & anti condensation: Thermostat controlled filtered exhaust fan; space heater with hygrostat.(e) Wiring: Cu FR LSZH, ferruled, ducted; control 1.5 mm²; power to auxiliaries 2.5 mm²; motor feeders per below.(f) Labels: Engraved traffolyte; terminal markers; danger and arc flash labels.(g) Docs: GA, SLD, IO list, terminal plan, cable schedule, test protocols (IR/HI POT/primary injection). |
| 98 | (II) Design, supply, install, testing and commissioning of Heat-Pump Side-Stream Piping, Valves & Instrumentation only Scope of work includes:-(a) Tee-off and tee-in connections on clean return header; branch piping (uPVC SCH-40/PN16 pool-grade) with solvent joints; supports/anchors.(b) Per branch: isolation valves (BV-1/BV-3), Y-strainer (1 mm) with blow-off, magnetic-flow-meter spool (meter by Others if separately priced), spring NRV, bypass/decoupler line with lockshield valve set to ≥10–12 m³/h minimum flow, rubber expansion joints, unions/flanges, drains and air-vents.(c) Static mixer on main header downstream of HP tie-in; chlorine dosing manifold & quill after mixer (≥2 m from tie-in); sample cock. |
| 99 | (d) Instrumentation on pool side: thermowells/strap-on temperature sensors (loop S/R and pool return), flow switch on each branch, pressure tappings with gauges; field JB near equipment; tagging.(e) Provide flanged/unioned stub-outs for connection to pump suction & discharge and HPU inlet & outlet; coordinate face-to-face and elevations with the separately-supplied equipment.(f) Terminate all instrument cables in local JB; final terminations in the separate control panel by Others.(g) Maintain straight lengths: tee-off ≥10×D after fittings; tee-in ≥5×D before mixer; dosing ≥2 m after mixer.(h) Test pressure ≥ 1.5× design (min 6 bar) for 2 h; demonstrate min-flow bypass setting per branch during commissioning.(i) Hydrotest, flushing, commissioning assistance, as-built drawings and O&M.Note : Complete design details, detailed technical specification, scope of work shall be as per annexure. |
| 100 | Supply install, testing and commissioning of Reinforced Bubble Cell Polyethylene Pool cover with the following specifications:-Material LDPE (Low Density Polyethylene) reinforced bubble cell constructionThickness : 500-600 micron with UV stabilized additivesWeight : 0.5 - 0.6 kg per sqmColour : Blue top with silver/transparent bubble underside for heat retentionUV Treatment : Minimum 2-year UV stability rating suitable for high altitudeTemperature performance : -10°C to +60°C operational rangeBubble diameter : 10-12mm for optimal strength and heat retentionBorder & Reinforcement : Heat-welded polyethylene border with reinforced hemFixing : Stainess steel 316-grade eyelets at 500mm centres along roller edgeDrainage : Micro-perforations or slope design for monsoon water managementSize : 25m x 9mRoller system : Stainless steel 316 grade roller tube and end supports, Manual winding with gear reduction mechanism, corrosion resistant hardware for high humidity environment, Anti-sag support wheel for large covers Weather protected storage capacityInstallation : Complete with commissioning, operator training and Maintenance manualMakes : Polco creations/DS water Technology/Potent Water Care/Lyxar Pools India/Aqvastar Smart Flow Solutions (Bengaluru) or equivalent with minimum 2-year warranty |
| 101 | M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6 mm thick burned directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1,5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32x6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh CI cover with frame, PCC chamber pit with PCC 1 3.6 type C-2 excavation and earth work all as shown in SSR Part I connected to earthing test point all as specified or indicated including testing on completion NOTES 1 The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. |
| 102 | M & L for cutting of existing pipe line of any size in position of inserting tee branches of required size, complete all as specified and directed by Engr-in-Charge. |
| 103 | M&L for construction of valve chamber (for sluice valves) 900mmx900mmx900 mm internal size, 100mm thick foundation using PCC 1:4:8, type D2, over 15 cm thick hard core, 20cm thick solid block masonary with blocks cast using PCC 1:3:6, type C 1, set in cement mortar 1:4, 15mm thick plaster to internal surfaces and external surface upto 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement, 1 mm thick MS sheet cover including 50mmx50mmx6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmx6mm flat iron hold fasts, handles, hinges with locking arrangements, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50mtrs complete all as specified and directed. |
| 104 | EXTERNAL ELECTRIFICATION: Shifting of existing transformer of capacity 63 to 200 kVA by providing crane/hydra/tractor/trolley from one location to another location complete with all other necessary shifting T&P as per site requirement. |
| 105 | Supply, Installation, testing and commissioning of air breaker gang operated device triple pole switch ( GOD) outdoor type, vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with 02 Nos clamp hook for protection of operating GI pipe including locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 200 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection complete all as specified and directed . |
| 106 | Supply and erecting 2 pole structure on steel tubular swaged poles including anti-climbing devices, channels/angles,connectors and other accessories necessary complete job for 2 pole structure complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) conforming to IS-1678 and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint including preparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip,including complete all as specified and directed. Note: Excavation and earth work and PCC for foundation, channel, clamps nuts, bolts to be measured and paid separately. |
| 107 | M&L Bus Bar Panel of capacity 300 Amps 6 way Aluminium bus bar with fixed on insulator including one MCCB 160A, 4P, 25kA fixed thermal magnetic release as incomer of panel and digital timer (for street light) 230V AC SPD upto 4kV fixed on DIN rail, complete panel with IP-54 protection outdoor type complete set welded with iron angle of size 50x50x6 mm, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed by Engr-in-Charge. |
| 108 | M&L Bus Bar Panel of capacity 300 Amps 6 way Aluminium bus bar with fixed on insulator including one MCCB 160A, 4P, 25kA fixed thermal magnetic release as incomer of panel and digital timer (for street light) 230V AC SPD upto 4kV fixed on DIN rail, complete panel with IP-54 protection outdoor type complete set welded with iron angle of size 50x50x6 mm, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed by Engr-in-Charge |
| 109 | S&F LT cable path indicator made of metal embossed with words LT cable 1100 volts duly pointed complete with necessary foundation all as specified and directed. |
| 110 | Supply and fixing of thermo plastic cable terminal box of size not less than 250x200x100 mm, including 3 phase terminals PVC connector for cable, locking arrangements including necessary mounting arrangement on street light pole with suitable size of clamps, nuts, bolts, washer, etc., complete all as specified and directed Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
| 10 | Click here to download tender document | Tender Documents |
| 11 | Click here to download tender document | Tender Documents |
| 12 | Click here to download tender document | Tender Documents |
| 13 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail