| 1 | Compound wall & Gate Sl No 01 to 22Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 2 | M&L Plain cement concrete (1:4:8) type D-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified. |
| 3 | M&L for formwork to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed. |
| 4 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished square, rectangular or polygonal surfaces of concrete complete all as specified and directed |
| 5 | M&L for formwork to faces of sides and soffits of floor or roof beams, cantilevers, shelves including supports, overhangs, etc for rough finished flat surfaces of concrete complete all as specified and directed |
| 6 | M&L for RCC design Mix M-30 (20mm graded aggregate) for foundations, includingrafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.(Note: Steel reinforcement shall be measured & paid separately) |
| 7 | M&L for RCC design Mix M-30 (20mm graded aggregate) for Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.(Note: Steel reinforcement shall be measured & paid separately) |
| 8 | M&L for RCC design Mix M-30 (20mm graded aggregate) for Columns, pillars, piers, posts and struts , complete all as specified and directed.(Note: Steel reinforcement shall be measured & paid separately) |
| 9 | TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 10 | TMT bars 8 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 11 | M&L Granite 20mm thick (of any type) work (table rubbed and polished) in shelf, jambs, window cills, partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 12 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 13 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 14 | M&L for Walling of random rubble uncoursed, well bonded bedded and solidly hearted built in CM 1:6 (below ground level) complete all as specified as directed. |
| 15 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed. |
| 16 | M&L for 15mm thick rendering in CM (1:6) internal plaster on brick/concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed. |
| 17 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including 3 mm thick exterior grade wall care putty in two layers completed all as specified and directed. |
| 18 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces completed all as specified and directed. |
| 19 | M&L for 100mm thick PCC 1:3:6 type C2 40mm graded aggregate as in plinth protection/paving/footpath, flooring, including 100 mm thick Hardcore of gauge n exc. 63 mm, deposited, spread andlevelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 20 | S&F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gates ,gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified and directed. Note : Rate is enclusive of welding , cutting , bending , moulding , small articles like spikes , flower design or any othet design selected by the accepting officer . |
| 21 | M & L for mild steel conforming to grade Fe-165 (Fe-290) angle post or struts, grating for rainwater passing in boundary wall etc in fencing fixed independently including cutting and bending to shape as directed drilling holes, notching for wire etc. complete all as specified and directed. |
| 22 | M&L for two coats of synthetic enamel paint on steel surfaces girth exc 10 cm and over a coat of red oxide incl preparation of new steel surfaces complete all as specified and directed. |
| 23 | Interlocking Block Sl No 23 to 31Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft loose soil. Complete all as specified and directed. |
| 24 | M&L for Hardcore of gauge n exc. 63 mm, of broken aggregate,deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, Complete all as specified and directed. |
| 25 | M&L for 100mm thick (compacted thickness) WBM with coarse aggregates of grading 1 (90 to 40mm size), spread, rolled and consolidated to gradient and camber required, Complete all as specified and directed |
| 26 | M&L for 100mm thick PCC type C-2 (1:3:6) (using 40mm grade stone aggregate) as in sub base of floor and path, Complete all as specified and directed. |
| 27 | Provision of precast factory made kerb stone type B1 1:2:4 20 mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 28 | M&L for providing and laying 80mm thick factory made rubber moulded chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 29 | S&F Providing precast cement concrete factory made louvres and jallies,50 mm thick (measured solid),type B0 , 1:2:4 ( 12.5 mm graded stone aggregate) set in CM 1:6 including all mouldings and fixing all as specified and directed. ( Note : Design shall be selected by the accepting officer) |
| 30 | S&F PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls all as specified and directed . Rate is enclusive of fixing of clamps, screws , scaffloding at G+2 height . |
| 31 | S&F PVC (SWR) bends 100 mm dia any radius all as specified and directed |
| 32 | Levelling nearby resience Sl No 32 to 35Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft / loose soil all as per specified and directd. |
| 33 | M&L Moorum filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering well ramming all as specified and directed. |
| 34 | M&L Rolling and consolidating formation surfaces in cutting power roller exc 8 tonne and not exc 12 tonne all as specified and directed. |
| 35 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 36 | Provn of Drain alongwith cover Sl No 36 to 41Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 37 | M&L Plain cement concrete (1:4:8) type D-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified. |
| 38 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed. |
| 39 | M&L for 15mm thick rendering in CM (1:6) internal plaster on brick/concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed. |
| 40 | Provision of coping type B1 1:2:4 20 mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 41 | Providing precast factory made drain cover slabs any shape and size , landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces with type B-1 1:2:4 ( 20 mm graded stone aggregate ) set in cement mortar 1:6 all as specified and directed. Please Enable Macros to View BoQ information |