| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16SWG) switch board cum JB on wall complete with 2no. suitable size “Ph&N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x 100mm x 65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish |
| 2 | Average Run -- 8 Mtr. |
| 3 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. |
| 4 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 5 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes as per GS. |
| 6 | 1.5 Sq mm |
| 7 | 2.5 Sq mm |
| 8 | Supply & Delivery of 2 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR ] |
| 9 | 2 core 10 Sq mm. cable. |
| 10 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as per GS. [ For 2 core 10 Sq mm. ] |
| 11 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry as per GS. |
| 12 | 2 core 10 Sq mm. cable gland. |
| 13 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS. |
| 14 | 2 core 10 Sq mm. cable |
| 15 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire as per GS. |
| 16 | Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required. |
| 17 | Fixing only 22 Watt Square Shaped LED Surface Mounted light fitting directly on the surface of beam/wall/false ceiling with necy. arrengements as required. |
| 18 | Supply & Fixing Ceiling Rose on existing point |
| 19 | Supply & Delivery of Single LED fitting (20 Watt, 230V AC, 50 Hz, 5700-6500K CDL, THD < 10%, built in 2.5 KV SPD) with all accessories and 1 no. polycarbonate LED Tube light (Colour- Cool Day White) as directed by EIC, Luminious efficacy 100 to 120 Lumen/watt. The LED luminaves & accessories shall have BEE certification. (Make- Philips/Crompton/Wipro) |
| 20 | S & D of Square shaped Surface mounted LED ceiling light ( Make - Phillips, Model - 59019, 22 Watt/Equivalent make of Crompton/Wipro, Colour - White, 6500 K ) |
| 21 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire as per GS. |
| 22 | Fixing only LED Street light/Flood light type fittings incl. making holes/providing clamping arrangement & necy. GI reducer as required on the existing arm brackets of the 9 mtr. height pole/Mini Pole Structure as per the direction of EIC. |
| 23 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmmPVC/A cable and having lined with rubber gasketted GI top coverwith brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. as per GS. |
| 24 | Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint |
| 25 | 1st coat of aluminium paint over one coat of RO priming |
| 26 | 2nd coat of aluminium paint over 1st coat |
| 27 | Supply & Delivery of Street light luminaire (IP 66) with peanut lens and high poer LED to ensure uniform distribution and higher spacing between poles, 10 KV SPD, THD<10%, PF> 0.95, BIS approved silicon filled potted driver, minimum LPW : 110 lumen/watt and minimum system output 7700 lumen suitable for use with 230 Volt, 50 Hz. ( Make - Phillips (Signify) /Havells/Wipro/Make - Crompton Greaves,) Colour - White |
| 28 | Supply & Delivery of Street light luminaire (IP 66) with peanut lens and high poer LED to ensure uniform distribution and higher spacing between poles, 10 KV SPD, THD<10%, PF> 0.95, BIS approved silicon filled potted driver, minimum LPW : 110 lumen/watt and minimum system output 11000 lumen suitable for use with 230 Volt, 50 Hz. ( Make - Phillips (Signify) /Havells/Wipro/Make - Crompton Greaves,) Colour - White |
| 29 | Dismantalling of the existing old electrical wiring from existing compound light fittings, dismantling of existing damaged outdoor light fittings - fixtures, old cables, damaged loop boxes etc. as per the requirement of site situation as per the direction of EIC. |
| 30 | S & F of Digital Time Switch ( Make - L&T, Cat No - Crono 67DDTO ) on the existing enclosure of the Timer control box incl. necy. Connection with required sizes of cu wire as required as per the direction of EIC. |
| 31 | S & F of 25 A, 2 Pole Power Contactor with 220 coil voltage ( Make- L&T - CS90240) on the existing enclosure of the Timer control box incl. necy. Connection with required sizes of cu wire as required as per the direction of EIC. Please Enable Macros to View BoQ information |