| 1 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Up to 160A |
| 2 | 4 way (Make - Legrand / L&T / Schneider) |
| 3 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. |
| 4 | 63 A (Make - Legrand / L&T / Schneider) |
| 5 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make - Legrand / L&T / Schneider) |
| 6 | i) 63 A TP MCB |
| 7 | ii) 6-32 A SP MCB |
| 8 | Supplying and fixing MCCB SS enclosure with IP-20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment(Make - Legrand) |
| 9 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[Make: L&T] |
| 10 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. |
| 11 | Average run 6 mtr |
| 12 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish.[only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 13 | Average run 6 mtr |
| 14 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required |
| 15 | (i) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 16 | (ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 17 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 18 | (i) 2.5 sqmm |
| 19 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. |
| 20 | (a) 150 mm x 100 mm x 65 mm |
| 21 | (b) 240 mm x 200 mm x 65 mm |
| 22 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wireetc. |
| 23 | Supply & Fixing 240 V, 10 A, 2(Two) way Modular type switch (approved make) on existing GI Modular switch board having top cover plate and making necessary connections as required. |
| 24 | Supply and fixing of Timer DB concealed in wall after cutting the wall & mending good the damages to original finish incl. necessary Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. The Timer DB comprises of following items -i) Double door enclosure (2+8 way) with IP42/43 protection - 1 No. [Make: Legrand]ii) 240V, 32A DP Isolator (Incomer) of - 1 No. [Make: Legrand]iii) Digital time Switch - 1 No. [Make: Legrand, Cat. No.- 412631]iv) 240V, 25A, 2 Pole power contactor (2NO) - 2 Nos. [Make: Legrand, Cat No.- 412544]v) 240V, 6A SP MCB (Outgoing) of Breaking capacity 10kA & 'C' curve characteristics - 2 Nos. [Make: Legrand]vi) Copper bar for 'Ph', 'N', 'Earth'vii) Blank cover plate as required |
| 25 | Supply & Delivery of 240V, 50 Hz, 1200 mm sweep, 380 RPM, 50-55W Heavy duty A.C ceiling fan with safety wire having minimum of 2(Two) years warranty support. [Make- Usha, Model- STRIKER NEO HI-SPEED ISI 1 STAR (Safety Wire) or equivalent make of Crompton / Orient Electric] |
| 26 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 27 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 28 | Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop. |
| 29 | Supply of 240V, 50 Hz, 300 mm (12\\") sweep, 920 RPM, 48 Watt heavy duty A.C Exhaust fan complete with all accessories (Make- EPC Electric Pvt. Ltd.) |
| 30 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 31 | 30 cm (12\\") |
| 32 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 33 | 30 cm Exhaust fan (12\\") |
| 34 | Supply & Delivery of 250 volt. 4 Ft. Long double LED Tube Light fittings (Make: Philips, Model- TMC 502 2xT-LED 22W or equivalent model of Crompton / Wipro) complete with all accessories incl. 2 no. 18/20 Watt LED Tube light. (Make: Philips, Model- Mas LEDTube 1200mm 18W 865 T8 I – 2100lm or equivalent model of Crompton / Wipro) |
| 35 | Supply & Delivery of 250 volt. 4 Ft. Long single LED Tube Light fittings (Make: Philips, Model- TMC 502 1xT-LED 22W or equivalent model of Crompton / Wipro) complete with all accessories incl. 1 no. 18/20 Watt LED Tube light. (Make: Philips, Model- Mas LEDTube 1200mm 18W 865 T8 I – 2100lm or equivalent model of Crompton / Wipro) |
| 36 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. |
| 37 | Supply & Fixing 10 Watt LED Bulkhead fitting having Pressure die cast aluminium housing with IP66 protection and IK09 impact resistance on wall / ceiling by screws etc. (Make- Philips, Model- WT202W LED10S CW PSU S3 PC or equivalent make of Crompton / Wipro) |
| 38 | Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991) |
| 39 | Supply & Delivery of 1.1kV grade aluminium armoured PVC/XLPE insulated cable. [Make: Ploycab / Havells / RR Kabel] |
| 40 | i) 4 core 50 sq.mm. |
| 41 | ii) 4 core 25 sq.mm. |
| 42 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. |
| 43 | Laying of cable as below, after cutting floor / pavement / wall and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. |
| 44 | (i) From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. |
| 45 | (ii) Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. |
| 46 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. |
| 47 | Up to 50 sqmm |
| 48 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 49 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. |
| 50 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 51 | (a) 4 core 50 sq.mm. |
| 52 | (b) 4 core 25 sq.mm. |
| 53 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 54 | (i) 4 core 50 sqmm |
| 55 | (ii) 4 core 25 sqmm |
| 56 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe |
| 57 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 58 | Connecting the equipments to earth busbar including S & F No. 4 SWG Solid GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. |
| 59 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6 mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 60 | With 25x25x3mm angle iron support200x50x1.25mm (18SWG) |
| 61 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 62 | (a) 50 mm dia |
| 63 | TERMS & CONDITIONS |
| 64 | (i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST.(ii) The Agency must procure the materials for the Manufacturer / OEM or from their authorized sales channel, so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.iii) Documents that authenticate such procurement from the manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill.iv) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. Please Enable Macros to View BoQ information |