| 1 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125A, 16 KA, TPMCCB |
| 2 | S/I/T/C of MCCB Sheet Metal Enclosure,4P, 100 A-125 A |
| 3 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 4 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural |
| 5 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way , Double door |
| 6 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 7 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 8 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 225 mm width X 50 mm depth X 1.6 mm thickness |
| 9 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 225 mm width X 50 mm depth X 1.6 mm thickness |
| 10 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 6 x 1.5 sq. mm |
| 12 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 9 x 1.5 sq. mm |
| 13 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm |
| 14 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia |
| 15 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm dia |
| 16 | SITC of 10 W surface/wall mounted LED Bulkhead factual impact dust and water resistant luminairies with IP65/66 Protection |
| 17 | Supply of XLPE insulated PVC sheathed Al. conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4Core*50 sqmm |
| 18 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 19 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 20 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 50 sq. mm (35 mm) |
| 21 | Supply, installation, Testing and Commissioning of 20 Passenger (1360 Kg) lift having contract speed of 1 m/s serving different floors in the existing lift shaft as per detailed specifications enclosed and as under: a) Location of lifts: Mata Gujri Hospital, Tilak Nagar, New Delhi-110027i) Speed: 1 m/s ii) Floors: Ground + basement + fiveiii) Travel :- 23.18 Mtr/ as per site iv) Stops and Opening: 07 stops/07 openingv) Controller: A.C. Variable voltage and variable frequency vi)Automatic rescue device complete with dry maintenance free batteries as required vii) Operation: Microprocessor based single automatic push button/simplex selective collective / without attendant viii) Power- 415 V ± 10%, 3 phase,50 Hz, 4 wires system ix)Types of doors:a) Car: Automatic Power operated, centre opening horizontal sliding stainless steel hairline finish b) Landing doors: Stainless steel doors hairline finish.x) A handrail Placed at a height of 800 mm to 900 mmfrom the floor level and Be fixed on both sides and at the rear ofthe lift xi) voice announcement system along with a visual display to indicate the floor level, car status and also the information that the door of the elevator is open or closed for entrance or exit. xii) overspeed governer, mirror,` infra read door screen, overload indicator, fireman switch, ARD, battery operated emergency alarm light, two way intercom with press and speak in COP etc as required. Machine room less as required |
| 22 | Comprehensive maintenance of lifts which include routine, preventive & breakdown maintenance for a period of five years including repair/replacement of worn out items with minimum downtime and warranty & guarantee of repaired/replaced items after completion of one year guarantee period |
| 23 | Supply, Installation, Testing & Commissioning of Direct drive axial fans complete with casing & motor, with impeller (Hub and blades) constructed of die cast aluminium alloy. Impeller should have aerodynamic profil, Direction of discharge and rotate position shall be as per the job requirement and shall be marked on the fans assembly. The motor shall be Class H with 250 deg. 2 hr. fire rating & suitable for 415V / 50Hz / 3 phase power supply.11,000 CFM, 30 mm Static Pressure |
| 24 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet |
| 25 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet |
| 26 | Supplying & fixing of powder coated extruded aluminium fresh/exhaust air Louvers with bird screen but without volume control damper as per specifications |
| 27 | Supplying & fixing of powder coated extruded aluminium Supply Air Grill without volume control damper as per specifications |
| 28 | Design, manufacture, supply, installation, testing and commissioning of the following upto 5.5 kW cubicle type DOL Starter Panel, dead front, sheet steel, wall mounted control panels including anchoring into the wall. The incoming power supply shall be provided by the other agency/client. |
| 29 | Supplying of XLPE insulated PVC sheathed aluminium conductor armoured cables 1.1KV grade conforming to IS-7098 Of following Size. 4CX10 SQ mm |
| 30 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 31 | Supply, Installation, Testing & Commisioning of Flexible Canvass Connections Please Enable Macros to View BoQ information |