| 1 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125A,36KA,FPMCCB |
| 2 | 125 A, 16 KA,TPMCCB |
| 3 | 250 A,50KA,FPMCCB |
| 4 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 5 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 6 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 7 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 8 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surfaceas required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 10 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 11 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way , Double door |
| 12 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required. |
| 13 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE5 Star rated, Ceiling fan with Brushless Direct Current (BLDC) Motor, class of insulation:B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power factor not less than 0.9, Service value (CMM/W) minimum 6, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 HZ, Single phase AC Supply, earthing etc. complete as required |
| 14 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 15 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm |
| 16 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 6 x 1.5 sq. mm |
| 17 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm |
| 18 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia |
| 19 | S/I/T/C of MCCB Sheet Metal Enclosure,4P, 100 A-125 A |
| 20 | SITC of 10 W surface/wall mounted LED Bulkhead factual impact dust and water resistant luminairies with IP65/66 Protection |
| 21 | S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: a) Total system wattage 20 Watt + - 5 % c) Luminious efficacy lumens/watt >=95 d) Power factor >= 0.95 |
| 22 | Supply of XLPE insulated PVC sheathed Al. conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4Core*25 sqmm |
| 23 | Supply of XLPE insulated PVC sheathed Al. conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4Core*95 sqmm |
| 24 | Supply of 15\\" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required |
| 25 | Supply, installation, Testing and Commissioning of 20 Passenger (1360 Kg) lift having contract speed of 1/1.5 MPS serving different floors in the existing lift shaft as per detailed specifications enclosed and as under: a) Location of lifts: Mata Gujri Hospital, Tilak Nagar, New Delhi-110027i) Speed: 1/1.5 MPS ii) Floors: Basement + Ground + Twoiii) Travel :- 12 Mtr/ as per site iv) Stops and Opening: 04 stops/04 openingv) Controller: A.C. Variable voltage and variable frequency vi)Automatic rescue device complete with dry maintenance free batteries as requiredvii) Operation: Microprocessor based single automatic push button/simplex selective collective / without attendant viii) Power- 415 V ± 10%,3 phase,50 Hz, 4 wires system ix)Types of doors:a) Car: Automatic Power operated, centre opening horizontal sliding stainless steel hairline finish b) Landing doors: Stainless steel doors hairline finish.x) A handrail not less than 600 mm long at 900 mm above floor level to be fixedadjacent to control panel in lift car xi) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator xii) overspeed governer, infra read door screen, overload indicator, fireman switch, ARD, battery operated emergency alarm light, two way intercom with press and speak in COP etc as required. |
| 26 | Supply, Installation, testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated, specially designed Al bus bar 400 A to 630 A with heat shrinkable colour coded sleeves suitable for accommodating MCCBs/MCBs/lsolators as incoming and outgoing as required (without MCCBs/MCBs/lsolators) complete with digital meter Module, including Voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required (conforms to 15:8623). I/c removing the existing panel etc and reconnecting the inputs to existing submain |
| 27 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm |
| 28 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 29 | Comprehensive maintenance of lifts which include routine, preventive & break down maintenance for period of five years including repair/replacement of worn out items with minimum downtime and warranty & guarantee of repaired/replaced items after completion of one year guarantee period. |
| 30 | Supply, Installation, Testing & Commissioning of Direct drive axial fans complete with casing & motor, with impeller (Hub and blades) constructed of die cast aluminium alloy. Impeller should have aerodynamic profil, Direction of discharge and rotate position shall be as per the job requirement and shall be marked on the fans assembly. The motor shall be Class H with 250 deg. 2 hr. fire rating & suitable for 415V / 50Hz / 3 phase power supply.11,000 CFM, 30 mm Static Pressure |
| 31 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet |
| 32 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet |
| 33 | Supplying & fixing of powder coated extruded aluminium fresh/exhaust air Louvers with bird screen but without volume control damper as per specifications |
| 34 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness notless than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 35 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 36 | Supplying & fixing of powder coated extruded aluminium Supply Air Grill without volume control damper as per specifications |
| 37 | Design, manufacture, supply, installation, testing and commissioning of the following upto 5.5 kW cubicle type DOL Starter Panel, dead front, sheet steel, wall mounted control panels including anchoring into the wall. The incoming power supply shall be provided by the other agency/client. |
| 38 | Supplying of XLPE insulated PVC sheathed aluminium conductor armoured cables 1.1KV grade conforming to IS-7098 Of following Size. 4CX10 SQ mm |
| 39 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 40 | Supply, Installation, Testing & Commisioning of Flexible Canvass Connections |
| 41 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 42 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 43 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineerin- Charge. |
| 44 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) |
| 45 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 46 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 47 | White washing with lime to give an even shade :Old work (two or more coats) |
| 48 | Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick |
| 49 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 50 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 51 | Disposal of materials by mechanical transport including loading ,unloading and stacking lime ,moorum, building rubbish for lead 8 km Please Enable Macros to View BoQ information |