| 1 | Supply, Erection/Construction, Installation, Testing, Commissioning and satisfactory trial runs of advance fully automatic (having Micro processer-based control unit with IOT/intranet/internet web-access, remote monitoring capabilities 5KLD capacity Faecal Sludge Treatment Plant (FSTP) of any suitable open technology being adopted anywhere in India for Primary, Secondary & Tertiary/any other treatment of faecal effluent meeting the standards prescribed by the MoEF&CC, GoI./CPCB/ANPCC, as amend to date with treatment/reuse/safe disposal of sludge. The work including all Civil, Plumbing, Mechanical, Electrical & Instrumentation works along with spares wherever required as approved by Engineer-in-charge. Including 05 years of Operation & Maintenance of FSTP including deputation of technical manpower for testing, operation & monitoring/supervision of Plant. |
| 2 | Sub Head: Construction of RCC retaining wall of height 1.75 mtr including CC approach road at Dasarathpur, Rangat.Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All kinds of soil. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 8 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 12 | Foundations, footings, bases of columns, etc. for mass concrete |
| 13 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 15 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 17 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | Cement concrete pavement with 1:2:4(1 cement: 2 coarse sand :4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 19 | 12 mm cement plaster of mix: |
| 20 | 1:4(1 cement: 4 fine sand) |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 22 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 23 | Providing and fixing in position PVC pipe for weep hole in walls including cutting into size and placed at proper intervals by binding etc. all complete as per the direction of Engineer-in-chagre. |
| 24 | 50 mm dia. |
| 25 | Providing and filling of material behind the wall for weep holes etc all complete as per the direction of Engineer-in-charge. |
| 26 | Stone aggregate of size 53 mm to 22.40 mm |
| 27 | Sub Head: SITC of 10 KVA DG Set and Providing IEI & EEI to Faecal Sludge treatment.Supplying, installing and commissioning of Silent type ' Diesel generating set of 10 KVA with water cooled Diesel Engine, Electric start with suitable capacity 12 V battery, fitted complete with all the required accesories along with AC Alternator 3 Phase, 415 Volts, 50 Hz, 0.8 pf self Excited, Self Regulated Designed with Acoustic Enclosure(sound proof) as per CPCB-IV+, emission norms approved DG Set similar to KIRLOSKAR GREEN Make,Model:3R550NA 4GI or Equivalent. |
| 28 | Supply,inastallation, testing and commissioning of standard fully automatic mains failure panel for 10 KVA capacity genset of suitable size with following technical specification. (a)Electricity board supply of loading/Unloading in off/manual/auto mode.(b)Selectable Auto/Manual Start/Stop of the generator. (c)Selectable Auto/Manual loading/unloading of the generator. (d)Interlocking loops with solid state logic circuit to avoid shorting of EB supply side and generator supply side. (e) Short circuit protection system for both EB side and generator side. (f) Over load protection system for generator (g)Single phase reversal prevention system. (h) Phase sequence sensing system. (i) Time sensing system for all operation (j)Monitoring digital system for voltage, amps, and frequency.(k)Short circuit protection for DC circuit. (l)Fully automatic battery charger with all protections. (m) Manual Change over for EB by pass. |
| 29 | Wiring for light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sqmm.FRLS PVC insulated copper conducotor single core cable etc. as required . |
| 30 | Group-C |
| 31 | Wiring for Light/ power plug wiring with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 32 | Wiring for Circuit/ sub main Wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. |
| 33 | 2x1.5 sq.mm + 1x1.5 sq.mm. earth wire |
| 34 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 35 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch, connections etc. as required. |
| 36 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular switch, connections etc. as required. |
| 37 | Installation, testing and commissioning of wall barcket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 38 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 39 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 40 | Supplying and Fixing of PVC Button / Angle Holder including connection etc as required. |
| 41 | Supplying and fixing following way, horizontal type Single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 42 | 6 -way , Double door. |
| 43 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 44 | Single Pole |
| 45 | Supplying and fixing following rating , double pole , 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 46 | Supplying of smart LED Bulb Similar to Havells LED ADORE 9w B22 CDL 2 STAR Lamp or Cromton/ Bajaj/ Havells/ Philips. |
| 47 | Supplying of 12W LED, 6000K ED Bulk head fittings similar to Luker, cat no. LBKOVSL 12 its equivalent. |
| 48 | Supply of 20W LED Retrofit Tube light Batten Make: Crompton, Model: DIJB12LT8-20 or its equivalent to IS specification. |
| 49 | Supply of 20W LED,6500K, 4 Feet, Retrofit Tube light similar to Philips, Model no. 20W865 T8 IND I 2100lm or its equivalent to IS specification. |
| 50 | Supplying of 5 star Energy saving ceiling fans BLDC (26W to 32W), 1200mm sweep (White), Make: USHA Model: Techno Air (Without remote) or equivalent. |
| 51 | Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 KV grade of size 25 sq.mm x 3.5 core conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 52 | Supplying and laying of DWC HDPE pipe of size 50/38, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc. on open surface as required. |
| 53 | 50 mm dia (OD-50 mm & ID-38 mm nominal) |
| 54 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1kV grade of following size in the existing HDPE/DWC pipe as required. |
| 55 | Upto 35 sq. mm |
| 56 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1kV grade of following size in the existing open surface/duct as required. |
| 57 | Upto 35 sq. mm |
| 58 | Providing Earthing with safe earthing electrode of galvanization 80 to 100 microns length 2000 mm, 48mm dia and inner space to be filled with crystaline conuctive mixture including filling - up with electrodite (Back fill Compound) 50kg for safe earth electrode and provoding masonary enclosure with cover plate having locking attagement etc. as required. (Similar to ASHLOK make SEE brand safe earthing or equivalent) |
| 59 | Providing· and fixing 25 mm X 5 mm· G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and refilling etc. as required. |
| 60 | Supplying and laying of DWC pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 61 | 40 mm dia (OD-50 mm & ID-32 mm nominal) |
| 62 | Supplying and laying of DWC HDPE pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc. on open surface as required. |
| 63 | 40 mm dia (OD-40 mm & ID-32 mm nominal) |
| 64 | Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 KV grade of size 6 sq.mm x 3 core conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 65 | Fabricating and Supplying of metallic street light pole made out of an overall length of 6.5 meters long having a bottom section length of 5.00 meters with 65 mm dia 'B' class ISI marked G.I Pipe.Top section having a length of 1.5 meters with 40 mm dia 'B' class ISI marked G.I Pipe suitably bended for installing 01 No Street Light having earth stud and necessary GI reducer/coupling fixed at the top & middle. Welding 300 mm x 300mm x 6mm thick MS base plate to the bottom including welding 100 mm X 25mm X 5mm M.S Flat for fixing PVC junction Box with 6A MCB on the Pole, i/c one coat of metalic primer and 02 coat of silver paint.Providing necessary wiring between junction box and st light fitting by 2x 1.5 Sq mm FR-LSH PVC Insulated copper conductor cable etc. as required. |
| 66 | Erection of pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top with including excavation and refilling etc. as required. |
| 67 | Above 4.5 meter and upto 6.5 meter |
| 68 | Supplying and Fixing LED street light of 30W with IP66 protection and impact resistance of IK07 equivalent to LUKER Sleek series street light product code LSTE-30 or its equivalent. |
| 69 | Supplying and Fixing 2 Way Metal Enclosure alog with doule pole 40A Isolator with necessary inter connections as required Make:indoasian cat no:810560I & 810130 or its equivalent. Please Enable Macros to View BoQ information |