| 1 | OLD BUILDING REPAIR BACK SIDE AND CORRIDOR AND RECEREATION ROOM |
| 2 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand) (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 3 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/ 10sqm |
| 4 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Imported Wood |
| 5 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cementconcrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 6 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 10kg/sqm (4mm thick) float glass panes inluding ISI marked M.S pressed butt hinges bright finished of required size with necessary screws.imported wood |
| 7 | Providing and fixing 35 mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm with wire of dia .0.63 mm for doors, windows and clerestory windows including I.S.I. marked black enameled M.S. butt hinges with necessary screws. |
| 8 | P/F of wooden Jaller panels of approved brand pattern and design of ist Class Kailr wood including Framing of Same by using First Class Kail wood and fixing with wooden Beeding complete job. Incl polishimng(For Gables & Windows) incl Scafolding all carriage upto site complete job incl Glass on both sides complete job |
| 9 | Providing and fixing Aluminium fixtures aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete |
| 10 | 250 x 16mm |
| 11 | Providing and fixing aluminium tower bolts ISI marked (anodised anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour of shade with necessary screws etc complete: |
| 12 | 250 x 10mm |
| 13 | 150 x 10mm |
| 14 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. |
| 15 | 125mm |
| 16 | 100 mm |
| 17 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :Single rubber stopper |
| 18 | Enaganement of Labours for Dismantling of Tile Works and other in Corridor incl Disposal of Material |
| 19 | Providing and fixing Ist quality ceramic Glazed Digital Wall Tiles conforming to IS : 13753 of miniumum thickness 6 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA or equivalent make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. Sizeof Tile 150-200x 900-1200 mm. incl Epoxy Complete job (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 20 | Providing and fixing in position factory-made / site-fabricated built-in cupboards, almirahs and shelving units of approved size, layout and design, fabricated out of waterproof commercial grade plywood conforming to relevant IS standards, using 19mm thick plywood for shutters, sides, top and bottom panels, 12mm thick plywood for shelves and intermediate members and 6mm thick plywood for back paneling, finished on all exposed external faces with 2mm thick decorative laminate (Dulmicka) of approved shade and pattern duly bonded with approved adhesive, and finishing internal faces with 0.8mm laminate / synthetic enamel as approved, including providing and fixing all necessary fittings and fixtures such as auto hinges, magnetic catches, locking arrangements, handles, tower bolts, drawer channels, shelf supports, PVC edge banding, screws, buffers and approved hardware, including cutting, grooving, edge finishing, alignment, shutter fixing and all incidental works, complete in all respects as per approved design and direction of Engineer-in-Charge. |
| 21 | Providing and fixing wooden wall panelling in Tongue & Groove (T&G) or other approved pattern made of first class seasoned hardwood/teak wood or equivalent approved wood, fixed over 10mm thick commercial plywood backing of approved make which shall be fixed over wooden framework/battens of required section, including all screws, nails, adhesives and necessary fixtures, complete with proper planing, grooving, jointing, sanding, filling with wood filler and finishing with one coat wood primer and two or more coats of synthetic enamel/duco/melamine polish or paint of approved shade and make, including all labour, materials, carriage and scaffolding, complete job as directed by the Engineer-in-Charge. |
| 22 | Providing and applying Decco wall paint finish of approved brand and shade over existing walls including removal/scraping of old paint, distemper or loose plaster, cleaning of surface and preparation of new smooth base with wall putty (minimum two coats), complete with rubbing, sanding and priming of surface. The work shall further include application of Decco paint in two or more coats to achieve uniform smooth finish, including providing and fixing necessary POP mouldings, cornices or decorative bands wherever required as per approved design and as directed by the Engineer-in-Charge, including all materials, labour, scaffolding, tools & tackles, surface preparation and finishing complete in all respects. |
| 23 | Providing and fixing at all height wall panelling with 18 MDF Baord wood on Budloo frame work & 12mm thick BWP ply board and fixing to frame work made of 50mm x 50mm hardwood plugs and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with ironscrews all complete as per direction of Engineer-in-Charge. |
| 24 | Providing and fixing wooden benches made of first class seasoned hardwood (Teak or equivalent approved wood) consisting of seat, backrest and legs of required size and design, including necessary framework, supports, arm rests where required, screws, nails, bolts and other fixtures, complete with proper planing, shaping, sanding and polishing with melamine/French polish to give smooth and finished surface, including all materials, labour, tools and tackles complete job as per approved design and directions of Engineer-in-Charge. |
| 25 | Providing & laying 16mm minimum thick pre-polished (best quality ) Granite stone slabs (non water absoring) in counters, vanities etc on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)/12mm thick backing of cement mortar 1:3 (1 cement : 3 coarse sand) and joined with white cement slurry mixed with pigment or with standard tile made compound to match the shade of the slab. Including rounding, rubbing, clamping, curing, moulding, granite polish & making grooves as required complete (Note: The stone slab shall be cut to required size and laid to the required pattern including rounding, chamfering, bull nosing of the edges as directed. Actual area of slab, as laid shall be measured) Sample to be approved by Engineer-in-charge. (including cost of all material, leads, lifts and carriages etc upto site of work |
| 26 | Providing and fixing factory made WPC/WPVC door shutter of approved make and design, made of solid WPC/WPVC board of minimum 30–35mm thickness, including necessary reinforcement, internal framework and stiffeners, complete with PVC edge banding and decorative laminated finish where required. The shutter shall be fixed in position with approved quality hinges, screws, tower bolts, handles, stoppers and other necessary fittings, including providing and fixing WPC/PVC door frame of suitable section where required, complete with cutting, fitting and alignment, including all materials, labour, carriage, tools and tackles complete job as per approved design and directions of Engineer-in-Charge. |
| 27 | Providing and laying Antiskid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600mm x 600mm |
| 28 | Park Gazeboo siting |
| 29 | Earth work in excavation by Manual means in foundation trenches, drains, pipes and cables etc.(not exceeding 1.5 Mtr. In width or 10 SqMts on plan) including dressing of sides and ramming of bottoms, lift upt 1.5 Mtr. Including getting out excavated soil and disposal of surplus soil as directed and lead up to 50 Mtrs . |
| 30 | Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete. |
| 31 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) incl all carriage complete job |
| 32 | Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. incl all carriage complete job All works Upto plinth Lvl |
| 33 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. @ 110Kg/Cum |
| 34 | Structural Work in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using CI etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.ORNAMENTAL WORK&carriages of all materials involved upto site of work complete |
| 35 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete on steel work |
| 36 | Providing and fixing polycarbonate sheet shading using multiwall/solid polycarbonate sheets of approved thickness (minimum 10mm or as specified) fixed over MS tubular frame work of suitable sections properly fabricated, welded and fixed in position with necessary purlins, brackets, nuts, bolts and self-drilling screws with EPDM washers, including cutting the sheets to required size, sealing joints with approved aluminium profiles and silicon sealant, complete with one coat of anti-corrosive primer and two coats of synthetic enamel paint on MS frame, including all materials, labour, scaffolding, carriage, tools and tackles complete job as per approved design and directions of Engineer-in-Charge. |
| 37 | Dismantling of Old Damaged Tiles Etc incl Disposal of Same |
| 38 | Providing and fixing Ist quality ceramic Glazed Digital Wall Tiles conforming to IS : 13753 of miniumum thickness 6 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA or equivalent make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. Sizeof Tile 450 x 300 mm. (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 39 | Providing and fixing Ist quality ceramic Antiskid Floor Tiles conforming to IS : 13753 of miniumum thickness 6 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA or equivalent make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. Sizeof Tile 300 x 300 mm. (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 40 | Providing and laying in position cement concrete in M-10 grade concrete excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost and carriage of all materials involved upto site of work complete. |
| 41 | P/F of 3.5mm hick glass panes with all fittings complete job |
| 42 | Providing and fixing factory made WPC/WPVC door shutter of approved make and design, made of solid WPC/WPVC board of minimum 30–35mm thickness, including necessary reinforcement, internal framework and stiffeners, complete with PVC edge banding and decorative laminated finish where required. The shutter shall be fixed in position with approved quality hinges, screws, tower bolts, handles, stoppers and other necessary fittings, including providing and fixing WPC/PVC door frame of suitable section where required, complete with cutting, fitting and alignment, including all materials, labour, carriage, tools and tackles complete job as per approved design and directions of Engineer-in-Charge. |
| 43 | Sanitary Fixtures: |
| 44 | Providing and fixing Indian type Water Closet (WC) of approved make in white glazed vitreous china, including 100mm P/S trap, set in cement mortar 1:3, properly connected with CI/PVC soil pipe, including providing and fixing foot rests, flushing cistern (PVC/ceramic) with all internal fittings, flush pipe, bend, unions, clamps and rubber connections, complete with necessary cement concrete bedding, jointing with cement mortar/white cement, testing and commissioning, including all materials, labour, carriage, tools and tackles complete job as per directions of Engineer-in-Charge. |
| 45 | Providing and fixing white glazed vitreous china wash basin (Flat back counter mounted/ oval or flat back) with 32mm C.P. brass waste of standard pattern, 32mm dia C.P. brass bottle trap and union, 32mm dia C.P. pipe to wall and C.P. wall flange, CP brass pillar cock, CP brass angle valve with braided connection pipe complete with fixing Brackets painted white, required C.P. brass screws, nuts, bolts, consumable complete, cutting and making good the walls wherever required. |
| 46 | Half threaded waste coupling: make jaquar or equivalent |
| 47 | Bottle trap: make jaquar or equivalent |
| 48 | Pillar cock make jaquar or equivalent |
| 49 | Angle Valve make jaquar or equivalent |
| 50 | 15mm dia braided connection pipe. make jaquar or equivalent |
| 51 | Providing and fixing Salem Stainless Steel A ISI 304(18/8) Kitchen Sink As per IS 13983 with CI Brackets ans stainless steel plug including painting of fttings and brackets, including cutting(GRANITE) and good the walls whereever required(900x1500) |
| 52 | Providing and fixing 20mm dia C.P. brass quarter turn angle valves with C.P. copper connecting pipe, union nut and C.P. brass wall flanges. make jaquar or equivalent |
| 53 | Providing and fixing 15mm dia C.P. brass bib cocks with wall flange. |
| 54 | Two way qauter turn bib cock |
| 55 | Providing and fixing of liquid soap dispenser with brackets fixed to wooden cleats with C.P. brass screws |
| 56 | Providing and fixing of CP brass Health faucet with 8mm dia 1 mtr. Long PVC tube and wall hook fixed to wall with rawl plugs and CP brass screws complete.Make Jaquar |
| 57 | B. Soil, Waste, Vent & Rain Water Pipes |
| 58 | Providing and fixing uPVC Pipes complete (IS: 4985 Class-III) with uPVC pipe fittings e.g. elbows, tees, reducers, unions, plugs, flanges etc. and clamps and jointing with solvent cement including chase cutting and making good the walls etc. wherever required for waste connection from W. B.Sink, floor drains etc.Make: Pipe:VECTUS/Kissan/AKG |
| 59 | 40 mm outer dia |
| 60 | 63 mm outer dia |
| 61 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil, waste, vent & rain water pipes). Nothing extra will be paid for supports. |
| 62 | 110 mm outer dia |
| 63 | 150mm outer dia |
| 64 | Cutting holes in RCC beam/Slab by diamond cutting technique.(Nothing extra payable for electrical and water supply required for the cutting operations) |
| 65 | 102mm dia Hole in 125mm thick slab |
| 66 | 152mm dia Hole in 125mm thick slab |
| 67 | Providing and fixing push fit floor clean plug of Upvc pipe. |
| 68 | For 110 OD Pipe |
| 69 | Water supply ( contractor Should make nipples from the same class of pipe, Readymade nipples will not be allowed |
| 70 | Providing and fixing 3 layer PP-R(Poly propylene Random copolymer) pipes SDR 7.4 UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge.(Make:Vectus,PRINCE) |
| 71 | PN-16 Pipe, 20mm OD |
| 72 | PN-16 Pipe, 25mm OD |
| 73 | PN-16 Pipe, 32mm OD |
| 74 | PN-16 Pipe, 40mm OD |
| 75 | PN-16 Pipe, 50mm OD |
| 76 | Exacavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms , depth upto 1.5 m including getting out the exacavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed within a lead of 50mtr. All kinds of soil Pipes, cables etc., exceeding 80 mm dia, but not exceeding 300 mm dia |
| 77 | P/F of Centrifugal Water Pump 1HP |
| 78 | Providing and fixing Cable Tray (200 mm wide) made of perforated/ladder type M.S. sheet not less than 2 mm thick, hot dip galvanized or powder coated, including bends, tees, reducers, couplers, suspenders, angle iron supports, anchor fasteners and other accessories as required, fixed to wall/ceiling with suitable supports at required spacing, including cost of laying and dressing of existing electrical cables/wires over the cable tray, proper clamping, alignment and finishing complete in all respects as directed by the Engineer-in-Charge. |
| 79 | CPO EXTENSION ROOM |
| 80 | Earth work in excavation by Mechanical means in foundation trenches, drains, pipes and cables etc.(not exceeding 1.5 Mtr. In width or 10 SqMts on plan) including dressing of sides and ramming of bottoms, lift upt 1.5 Mtr. Including getting out excavated soil and disposal of surplus soil as directed and lead up to 500 Mtrs . |
| 81 | Providing and laying of hand Packed stone soling complete job |
| 82 | Providing and laying in position cement concrete 1:4:8 grade (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) (under Footings) of specified grade excluding the cost of centring and shuttering All work upto plinth level i/c carraige with an av lead of 40 kms . |
| 83 | Providing and laying in position cement concrete 1:2:4 grade (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) (under Footings) of specified grade excluding the cost of centring and shuttering All work upto plinth level i/c carraige |
| 84 | Reinforced For RCC work incl Cutting bending complete job |
| 85 | Reinforced cement concrete work in beams , suspended floors roofs, landings Balconies including columns etc upto floor five level including curing but excluding cost of centering shuttering finishing and reinforcement. 1:1½:3(1 cement :1½ coarse sand :3 graded stone aggregate 20 mm nominal size) INCLUDING CARRIAGE |
| 86 | Brick work with common burnt clay selected bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) including curing complete in:With Non Modular bricks |
| 87 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete |
| 88 | Centering and shuttering including strutting, propping etc. and removal of form for: suspended floors , roofs landings . Balconies and access platforms etc |
| 89 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand) (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 90 | 12mm cement plaster in 1:6 (1 cement : 6 fine sand) (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 91 | P/F of imported wooden 12mm thick (T&G) panelling fixed on 12mm ply board i/c frame work of budloo wood,all fixtures compelete- job incl Polishiong with two or more coats incl cost of 12mm ply and framing complete job |
| 92 | P/F of wooden flooring of a class laminated wooden flooring (8mm) thick fixed on foam with proper resin material as per sample (MF-84 A with beading and door profiles |
| 93 | Providing & fixing wood work in frames of doors, windows & other frames, wrought framed & fixed in position including SS expansion fastners for brick/concrete work in (including cost of all material, leads, lifts & carriages etc upto site of work complete). Imported Wood |
| 94 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 10kg/sqm (4mm thick) float glass panes inluding ISI marked M.S pressed butt hinges bright finished of required size with necessary screws.Imported wood |
| 95 | Electric Part |
| 96 | Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mrn FRLS/HFFR PVC Insulated flexible stranded copper conductor wiros in recessed or surface medium class PVC conduit, with 240V 6A modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq mm FRLS/HFFR PVC Insulated copper conductor single core cable, etc, as required. (Havells/ Polycab/ Anchor/ SSK) Including the cost of conduit |
| 97 | Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes replacement warranty of fixture if damaged/burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/handing over of site to the intending department. (Havells/ Philips/ Crompton/Jaguar/Wipro). |
| 98 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) including bends, Tees, cross members and 3 allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc, as required.225 mm width X 50 mm depth X 1.6 mm thickness |
| 99 | Supply, installation, testing and commissioning of 400 mm BEE Star rated energy-efficient wall fan, complete with 3 Nos. blades, capacitor, front guard, spinner, rear guard, guard ring,wall mounting bracket and washers, suitable for 230 V, 50 Hz AC supply. air flow 2400- 2500cfm, blade pitch 120 degree, rated speed (RPM) between 1300-1400 (as per manufacturer's specification), power consumption not exceeding 60 watts, service value ≥ 6.0. noise level ≤ 60 dB, insulation class 'B' and insulation resistance > 2 MQ. Fan shall be of approved make such as Usha/Havells/Crompton/Orient/V-Guard or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in- Charge, with minimum 2-year manufacturer warranty |
| 100 | Supply, Installation, Testing and Commissioning of 50W (Havells/ Phillips/Wipro skyline) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w,CRI>80,CCT>5000,Avg Life L70 50000 hours, No haremful UV and IR radiators, Operating Temp -10°C to +45°C, Surge Voltage Protection, IP66 Protection and impact resistance of IK07. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. |
| 101 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc, as required. (Anchor roma plus/Legrand Mylinc/SSK/Schneider 20 Zencelo/Crabtree athena make). |
| 102 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required. (Anchor roma plus/Legrand Mylinc/SSK/Schneider Zencelo /Crabtree athena make). |
| 103 | Supply and fixing of 8 way (4+24), Double door surface/ recess mounting, Horizontal type, three pole and neutral, sheet steel, MCB distribution board, 415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB) |
| 104 | Supply and fixing of 4 way (4+12), Double door surface/ recess mounting, Horizontal type, three pole and neutral, sheet steel, MCB distribution board, 415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB) |
| 105 | Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 10 KA \\"C\\" curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections |
| 106 | Supply, installation, testing and commissioning of 40A-32A DP rating 240/415V, 10 KA \\"C\\" curve 11 MCB of Legrand/Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 107 | Supply, installation, testing and commissioning of 63A DP rating 240/415V, 10 KA \\"C\\" curve 12 MCB of Legrand/Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 108 | Supply, installation, testing and commissioning of 4 No. of Aluminium Bus Bar of 63 Amp. |
| 109 | Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade 14 flexible stranded copper conductor wires in recessed or surface conduiting system, excluding the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent) |
| 110 | 2x 6 sq mm + 1x 6 sq mm |
| 111 | 2x 4 sq mm + 1x 4 sq mm |
| 112 | 2x 2.5 sq mm + 1x 2.5 sq mm |
| 113 | 2x 1.5 sq mm + 1x 1.5 sq mm |
| 114 | Supply, laying, and fixing of 25 mm FRLS PVC Conduit (MMS)Material: Rigid PVC, FRLS for fire safety Medium Mechanical Strength (MMS) as per (S:9537 Size: 25 mm diameter Wall thickness: 21.5 mm. Suitable for indoor/outdoor use, excluding recessing and making good the walls same as before. |
| 115 | Supply and fixing of 25mm wide Medium Class PVC Casing & Capping (FRLS type) with necessary accessories such as saddles, couplers, tees, bends, and junction boxes, complete as per specifications. Please Enable Macros to View BoQ information |