| 1 | SH-I-Renting OUT AREA: Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 2 | In cement mortar |
| 3 | Taking out MS window along with grill work to make opening for toilet approach and cutting the window and grill work to the required size and refixing the same including finising the wall surface all complete as directed by the Engineer-in-Charge. |
| 4 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/rubbish to the nearest municipal dumping ground, all complete as per directions of Engineer-In-Charge. |
| 5 | For door/ window/ clerestory window. |
| 6 | Taking out grill work over the wall at lift room by cutting the clamps and stacking at site all complete as directed by the E-in-C. |
| 7 | Dismantling the wooden partition above the brick wall and stacking of materials at site all complete as directed by the Engineer-in-charge. |
| 8 | Removing the existing PVC flooring sheet from the floor, skirting and scrapping the adhesives neat and stacking the sheet at site all complete as directed by the E-in-C. |
| 9 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 10 | For fixed portion a) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 11 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). a) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 12 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 13 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 14 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 15 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 16 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length fixed from 4.5M height ceiling with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, |
| 17 | shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 18 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 19 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 20 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 21 | 250 mmX16mm |
| 22 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete :- |
| 23 | Twin rubber stopper |
| 24 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. |
| 25 | 150 x 10 mm . |
| 26 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 27 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 28 | Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 29 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 30 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 32 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 34 | Hot finished welded type tubes. |
| 35 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 36 | SH-II Additional Toilets work: Dismantling Rolling Shutter, its guide bar and cover including stacking the serviceable materials 50 metres lead |
| 37 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 38 | In cement mortar |
| 39 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 40 | Of area 3 sq. metres and below |
| 41 | Brick work with common burnt clay F.P.S. bricks of class designation 5.0 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 42 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 43 | Half brick masonry with common burnt clay bricks of class designation 5 in superstructure above plinth level up to floor V level. |
| 44 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 45 | Providing, hoisting and fixing up to floor seven level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor seven level, including the cost of required centering, shuttering but , including the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand ( crushed stone sand) : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 46 | Size:1.2x0.23x0.15 with 6 Nos 10mm dia reinforcement and 8mm stirrups at 150mm c/c. |
| 47 | 12 mm cement plaster of mix: |
| 48 | 1:6 (1 cement : 6 fine sand) |
| 49 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 50 | 1:6 (1 cement : 6 coarse sand) |
| 51 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level. |
| 52 | 1:4:8 (1 cement : 4 M sand : 8 graded stone aggregate 40 mm nominal size) |
| 53 | Supplying and filling in plinth with \\" M\\" sand under floors, including watering, ramming, consolidating and dressing complete. |
| 54 | Providing and fixing on wall face unplasticised Rigid PVC pipes including jointing with sealant all complete |
| 55 | 75 mm diameter |
| 56 | 110 mm diameter |
| 57 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC pipes conforming to IS : 13592 Type A including jointing conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 58 | 110 mm bend (Bend 87.5° ) |
| 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 60 | 20 mm nominal outer dia .Pipes. |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 62 | 25 mm nominal outer dia .Pipes. |
| 63 | Providing and fixing PVC trap of self cleaning design including cost of cutting and making good the walls and floors etc complete as directed by the Engineer-in-charge. |
| 64 | 100 x 75 mm |
| 65 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 66 | W.C. pan with ISI marked white solid plastic seat and lid |
| 67 | Providing and fixing wash basin with fischer Anchor bolts 10x140, 32 mm C.P. brass waste of standard pattern all complete as directed by the Engineer-in-Charge.: |
| 68 | White Vitreous wall Hung wash basin size 570x 440x200 mm . |
| 69 | Providing and fixing unplasticised PVC connection pipe with brass unions : |
| 70 | 30cm length ,15 mm nominal bore |
| 71 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 72 | Flexible pipe ,32mm dia |
| 73 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 74 | 15 mm nominal bore. |
| 75 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality. |
| 76 | 15mm nominal bore |
| 77 | Providing and fixing C.P. brass pillar cock of approved quality : |
| 78 | 15 mm nominal bore |
| 79 | Providing and fixing C.P. brass health faucet of standard design and of approved make. |
| 80 | 15 mm nominal bore |
| 81 | Providing and fixing PTMT grating of approved quality and colour. |
| 82 | 100 mm |
| 83 | Providing and fixing Ventilator frame using factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat…etc including glass louvers and its frame all complete as directed by the Engineer-in-Charge. Size:600x450mm |
| 84 | Supply & Fixing of WPC door frame and shutter of Qute or equivalent make with solid door frame extruded with size 75mm x 50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55, and Bulk Density 800 Grms / Cub.Mt.. The frame shall be fixed onto the wall using 8 x 100mm long M.S fastener Screw fitted with polymeric nylon sleeve. A minimum of 4nos screws to be provided for each vertical member.Shutter made of 30mm (+/- 1mm) thick WPC Decora Door which is extruded as a single core door with Lead-Free compound. The door is designed homogeneously by Smooth Routing and 3D embossed grains on one side. The other side of the door shutter shall be plain mat finish. The door must be completely made by machine, without any post-production fabrication. The Solid WPC board shall have minimum Bulk Density 650 KG/ Cub.Mt. The door is to be hinged to the frame with minimum 3nos of 5 inch Stainless steel butt hinges and provided with 2 nos of 75mm Stainless steel tower bolt, 2 nos of 75mm Stainless steel handle .Door size upto 0.80 x 2.10 metre with necessary fittings |
| 85 | Supplying and fixing Sandwich polyurethane foam (PUF )30mm thcik colour coated GI sheet roofing including necessary MS Hollow tubes frames and CP screws all complete as directed by the Engineer-in charge |
| 86 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete :- |
| 87 | Twin rubber stopper |
| 88 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of ISt quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 89 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 90 | Cleaning manhole chamber, removing the stagnated sewage water/ sludge, dust, silt, waste soil etc. and disposal of removed materials within 50m lead by taking earth pit and finally flushing the manhole with plenty of water to prepare the manhole to function properly. Due Care shall be taken while operating/ entering the manholes from direct inhaling of poisonous gases if any etc.all complete as directed . |
| 91 | All types and size of Manhole |
| 92 | Cleaning the sewer line including the stagnated sewage water/sludge, dust, silt and sand etc by inserting the bamboo splits into the sewer line and disposal of sludge materials within 150m lead by taking earth pit and cleaning with clean water complete |
| 93 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: |
| 94 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg): a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 95 | Constructions of brick masonry chamber of gully of size 300x300mm with water tight C.I. cover with frame of 300x300 mm size all complete as Directed by the Engineer-in-charge.: |
| 96 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 97 | Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 98 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 99 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 100 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Please Enable Macros to View BoQ information |