| 1 | Surface dressing n. exc 15cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and directed. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 1.5m in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and directed. |
| 4 | M&L Boring hole in rainwater harvesting pit in any type of soil of 550mm size bore etc complete all as specified and directed. |
| 5 | S&F 150mm Bore dia PVC/ HDPE pipe in bore hole complete all as specified and directed |
| 6 | S&F 150mm Bore dia perforated/slotted PVC/ HDPE pipe in bore hole complete all as specified and directed |
| 7 | M&L stone aggregate gravel of gauge 3.60 mm, complete all as specified and directed. |
| 8 | M&L cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 9 | Use of waste for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticle or to batter with rough finish flat surface, complete all as specified and directed. |
| 10 | M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire 0.9 mm dia, complete all as specified and directed. |
| 11 | M&L RCC M-30 (Design mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 12 | Use of waste for formwork (rough finished) to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttressess etc vertical or to batter, complete all as specified and directed. |
| 13 | M&L cement concrete M-30 (design mix) (using 20mm graded stone aggregate) as in walls, retaining walls, basement walls, ballast walls, and the like any thickness above top of footing incluidng attached pillaster and buttresses, complete all as specified and directed. |
| 14 | M&L 15mm thick rendering on fair faces of brick work /concrete surface in CM 1:6 using liquid water proofing compound by weight or cement as per manufacture instruction and finishing even and smooth without using extra cement all as specified and directed. |
| 15 | Supply only liquid integral water proofing compound comple all as specifed and directed. |
| 16 | M&L Hardcore of broken stone of gauge 40 to 60mm, deposited spread and leveled in layers n. exc 15 cm thick each layer, watered and rammed to a true surface complete all as specified and directed. |
| 17 | M&L broken stone aggregate of gauge 3 to 10 mm, complete all as specified and directed. |
| 18 | M&L sand filling under floor (Coarse Sand) on in foundation in layers not exceeding 25cm thick each layer including watering and well ramming complete all as specified and directed. |
| 19 | S & F mild steel plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, riveted, bolted or welded attachment complete all as specified and directed conforming to Fe-410 W |
| 20 | Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 21 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors dia of pipe 150 mm complete all as specified and directed. |
| 22 | S&F 100 mm dia vent PVC (SWR) pipe 600mm long, bent to shape, with fittings as vent pipe complete all as specified and directed. |
| 23 | Use of waste for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick finish with rough finish flat surface complete all specified and directed. |
| 24 | M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. |
| 25 | M&L for pre-cast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in manhole covers and set in cement mortar (1:4) including use and waste necessary form work complete all as specified and directed. |
| 26 | Removing excavated material to a distance exc 50 m and n.exc 100 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 27 | S&F cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings railing frames,manhole covers, fire and soot doors, dampers, stop valves boxes, gate stops, part of ranges, balusters ans similar articles complete all as specified and directed. |
| 28 | M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 29 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out etc as in any type of soil complete all as specified and as directed. |
| 30 | M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan, exc. 6m mean radius or cement concrete, built in cement mortar 1:6 as in manholes, septic tanks, soakage pits, drain etc in any position complete all as specified and directed. |
| 31 | M&L PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in surface channel, foundation filling,wall coping, and mass concrete etc, complete all as specified and directed. |
| 32 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends, complete all as specified and directed. |
| 33 | Add or deduct for each 25 mm girth or part thereof over or under 30cm in above item complete all as specified and directed. |
| 34 | M&L for 15 mm thick rendering on Brick mansonary or other than fair faces of brick wall for external CM 1:4 finished even and fair without using extra cement, complete all as specified and directed. |
| 35 | Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 36 | Demolition of concrete of any description in any position complete all as specified and directed. |
| 37 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 38 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 39 | M&L 75mm thick for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection and path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) part bitumen 85/25 and 3 parts of sand complete all as specified and directed. (Note:-Rate is deemed to be inclusive of materials against forming & filling of joints) |
| 40 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 41 | M&L for 10 mm thick rendering in cement mortar (1:6) on fair faces or brick work of concrete surfaces of walls, finished even and smooth (without using extra cement) complete all as specified and directed. |
| 42 | M&L for 5 mm thick rendering in cement (1:3) on fair faces of concrete as in ceiling, finished even and smooth without using extra cement complete all as specified and directed. |
| 43 | S&F GI wire netting/ Chicken wire mesh 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and directed. |
| 44 | M & L for three coats of white wash on New surfaces (wall) including all prereration complete all as specified & directed |
| 45 | M & L for three coats of white wash on New surfaces Ceiling including all prereration complete all as specified & directed |
| 46 | M & L for prepration of old surfaces and applying two coats of white wash on wall surfaces including all preperation complete all as specified & directed. |
| 47 | Providing and applying 1.5 mm thick wall care putty over plastered surface to prepare the surface even and smooth all as specified and directed. |
| 48 | M&L applying two coats OBD including one coat of primer complete all as specified and directed. |
| 49 | M&L for preparation of old decorated wall surfaces including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying one coat of distemper oil bond emulsion by using rollers complete all as specified and directed. |
| 50 | M&L for preparation of old decorated surfaces (plastered/ un-plastered) of ceiling incl cornices by brooming down with steel brush, scrapping down smoke soot, moulds, moos and efflorescent salts and trading oil and greasy spots and applying One coat of white wash on ceiling complete all as specified and directed. |
| 51 | M&L coloured non skid tile 7 to 8mm thick (square/ rectangular) area of each tiles exc.o.06 sqm n exc.,0.18 sqm in floor etc. set and jointed with neat cement slurry and pointed in colur cement to match over and including 15 mm thick screed bed in cm 1:6 complete all as specified and directed. |
| 52 | M&L glazed ceramic tiles of size 450x350x/6/7 /350x250x7/ 300x200x7mm thick coloured tiles on walls such as skirting and dado and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cm (1:4) finished fair and rough as backing coat complete all as specified and directed. Please Enable Macros to View BoQ information |
| 53 | M&L glazed ceramic tiles of size 450x350x/6/7 /350x250x7/ 300x200x7mm thick coloured tiles on walls such as skirting and dado and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cm (1:4) finished fair and rough as backing coat complete all as specified and directed. Please Enable Macros to View BoQ information |