| 1 | Surface excavation n exc 30 cm and averging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth and n exc 1.50 m deep and getting out soft or loose soil Complete all as specified and directed. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 1.5m in depth and n exc 3m deep and getting out soft or loose soil Complete all as specified and directed. |
| 4 | Excavation of trenches in any type of soil n.exc 1.5 M wide and n.exc 1.5 M in depth for pipe lines and getting out in soft/loose soil forming bottom surfaces to required gradients complete all as specified and as directed. |
| 5 | Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25cm deep as in soft/loose soil Complete all as specified and directed. |
| 6 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point Complete all as specified and directed. |
| 7 | M&L for hard core of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed. |
| 8 | M&L PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation Complete all as specified and directed. |
| 9 | M&L for form work to sides of concrete foundation, footing, bases of columns, plinth beams and similar work, vertical or to batten rough finish flat surfaces on concrete complete all as specified and directed. |
| 10 | M&L for form work to sides and soffit of floor RCC walls or floor beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs etc also splays between floors and bemss etc rough finish flat surfaces on concrete complete all as specified and directed. |
| 11 | M&L for form work to sides of Pillars, posts, struts piers, columns etc in squarre, rectangular or polygonal, rough finished surfaces of concrete complete all as specified and directed. |
| 12 | M&L for use and waste of form work to soffits of suspended slabs such as roof slab, floor slabs, landings, roof beam and similar work, n.exc 200mm thick flat, rough finished surfaces of cencrete complete all as specified and directed. |
| 13 | M&L form wok to edges of concrete flats, treads, breaks in floors, windows cills, concrete railings, floor and roof n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specifed and directed. |
| 14 | M&L M-30 RCC using 20mm graded stone aggregate in foundation including footing, plinth beam, base for column, etc complete all as specified and directed. |
| 15 | M&L M-30 RCC using 20mm graded stone aggregate in for walls, beams, columns, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed. |
| 16 | M&L M-30 RCC using 20mm graded stone aggregate in for slabs sopported on walls ,beams and columns in floor s ,roofs etc complete all as specified and directed. |
| 17 | S&F Mild Steel CRS TMT round bars 10 mm dia and over, cut to length, bent to shape required, including cranking , binding spirally for hooping end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 18 | All as per item No.17.00 above but 5mm dia and over up to & including 10mm dia in stirrups, spacers & binders complete all as specified and directed. |
| 19 | M&L 10 mm thick rendering in cement mortar 1:4 on concrete surfaces finished with even and smooth mixed with Water Proofing compound complete all as specified and directed. (Note : WPC shall be measured and paid separately under relevant item of this Schedule). |
| 20 | Supply only Liquid water proofing compound Complete all as specified and directed. |
| 21 | S&F for Anodised aluminium ladder of ALC 60x40x1.87 mm thick vertical memebers & ALE 45x45x5 mm steps @ 300 c/c fixed to ALC 60x40x1.87mm of witdh of steps 500 mm fixed at bottom / top and given supports in middle in 3M depth UG sump etc complete all as specified and directed |
| 22 | M&L for 75 mm thick cement concrete (1:3:6) type C1 using 20 mm thick graded stone aggregate as in plinth protection laid in alternate bays n exc 2.5m length finished even & fair and joint to be filled with Bituminous mastic filling including necessary form work complete all as specified and directed. |
| 23 | M&L preparing new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces. |
| 24 | S&F 150mm deep water bar for underground sump complete all as specified and directed |
| 25 | S&F for 75mm thick steel fibre reinforced (SFRC) man hole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard, minimum load bearing capacity 5 ton/sqm, in square, rectangular or circular shape complete all as specified & as directed. |
| 26 | M&L for vibrator moulded precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade and fixed with grey cement and pigment laid over and including 25 mm thick sand cussion and filled the joints with dry sand after laying the paver block complete all as specified and directed. |
| 27 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed |
| 28 | M&L for prepartion of newly concrete surface as kerb stone surface and applying two coat of synthetic enamel paint over a coat of primer as approved complete all as specified and directed |
| 29 | M&L for dry sand and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured. |
| 30 | Supply & laying sub class B bricks, locally available un-burnt bricks suitable for LT cable protection cover all as specified and as directed by Engineer-in-Charge |
| 31 | Supply, laying, jointing and testing 25 sqmm, 4 core XLPE insulated armoured heavy duty LT under ground electric cable with aluminum stranded conductor 1100 Volt grade following cross sectional area laid in trenches/ducts or foxed on wall by saddling, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable.Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 32 | M&L for earthing to electric equipments / panels with and including galvanized MS earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized mild steel strip 25mm x 4mm as earth lead, welding at top of electrode and other end of strip connected to equipment body/panel/test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level fixed along equipment body/panel with and including 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. |
| 33 | M&L for galvanized steel water tubing medium grade of 80mm bore with & including all fittings complete laid in trenches. Note :- Excavation & earthwork shall be measured & paid for separately. |
| 34 | M&L for galvanized steel water tubing medium grade of 50mm bore with & including all fittings complete laid in trenches. Note :- Excavation & earthwork shall be measured & paid for separately. |
| 35 | M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors. |
| 36 | M&L for galvanized steel water tubing medium grade of 15 mm bore with & including all fittings complete Fixed to walls , ceilling or laid in floors. |
| 37 | S&F in repairs 20mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked. |
| 38 | M&L , jointing and testing of all kind for of DI (Ductile Iron) pipe, round flanged end on both sides of 100 mm dia , K-9 complete with rubber gasket nuts, bolts and washers inside OPC coated, white painted inside and black painted on out side including all kind of fittings as required and taking down old unsv pipe complete all as specified and as directed by Engineer-in-Charge.(Make : Jindal/ Electro Steel/ Tata). |
| 39 | Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 100 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete, all as specified & directed including dismantling & taking out old unserviceable sluice valve. Make-Kirloskar/Kartar/Zoloto/BIR |
| 40 | Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete, all as specified & directed including dismantling & taking out old unserviceable sluice valve. Make-Kirloskar/Kartar/Zoloto/BIR |
| 41 | Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 50 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete, all as specified & directed including dismantling & taking out old unserviceable sluice valve. Make-Kirloskar/Kartar/Zoloto/BIR |
| 42 | Supply, install, testing & commissioning of LT panel outdoor type (KIOSK) factory made powder coated paint made of 3 mm thick CRCA sheet, CPRI approved, dust and vermin proof protection, with 300 Amps copper bus bars front opened with locking arrangements mounted on angle iron frame 40x40x6mm, 45cm height from ground level comparising of the following accessories :-(a) MCCB 160 Amp 35 KA rating 4 pole 440 volts-01 No Make-ABB/Legrand/L&T(b) MCB-100 Amps, TPN 440 V, 16 KA-02 No Make-ABB/Legrand/L&T(c) Starter, star delta, fully automatic suitable for 15 HP 3 phase elect motor - 02 No Make-L&T/Havells/AE(d) Digital Amp meter with selector switch & CT 0-50 Amps - 01 No(e) Digital Volt meter with selector switch 0-500 Volts -01 Nos(f) Single phase preventor mini lec VSP-II-01 No Make-Havells/ABB/L&T/BCH/C&S(g) Phase sequance corrector 20 HP motor, 3 phase-01 No Make-Havells/ABB/L&T/BCH/C&S(h) LED Indicator lamp - 03 Nos (RYB)(j) Wiring with suitable size copper conductor cable for LT panel.(k) Power factor correction capictor bottle type, 3 KVAR 3 phase- 01 No Make- Legrand/ABB/EPCOS(l) relay should be min 42 amp-2 nos |
| 43 | S & F 1100 Volts grade submersible cable flate 3 core with copper conductor 10 sqmm stranded fixed to column pipes with suitable clamps jointing material complete. |
| 44 | Supply installation Testing and commissining submersible pump set Horizental type Electric driven 3 phase, 415 volt, 50 c/s having discharge upto 14000 Lit / hrs at 200 m head 18 stage not less than 20 HP.Make- KSB/Kirlosker/CG. |
| 45 | Trial bore holes 150mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer - in charge complete including submitting the strata details both graphically recorded as well as strata results.Note :- The rates quoted shall deemed to include to get survey done for availability/facibility of water as recommended by CGWD before execution of work. |
| 46 | M&L for bore by drilling with rotary system/ODEX system of 250mm dia in hard rock /Disintigrated rock till meeting water strata all as directed. |
| 47 | All as per srl item No 46.00 but of 250mm dia in hard rock and drilling with DTH system till meeting water strata all as directed. |
| 48 | Supplying and assembling jointing lowering and fixing in position of ERW MS casing pipe 200mm dia of 5.4mm thickness ( minimum ) upto required depth below ground level in all strata (including cutting welding as required, painting etc complete ISI marked including MS well cap and also as specified and directed by Engr-in -charge. Make - TATA/Swstik/Jindal/Prakash |
| 49 | Supply, assembling, including jointing lowering and fixing in position ERW MS slotted pipe 200mm dia of 5.4mm thickness ( minimum ) having slots of 1.59 mm wide, 75 mm long assembled and lowered as per location chart approved by the GE including cutting welding as required and painting etc complete all as specified.Note for Sr Item No 48.00 & 49.00 :- Rate quoted by contractor shall deemed to include for S&F well cap 200 mm dia on top of pipe with locking arrengement till the bore well become functional complete. |
| 50 | Supply and packing with Pea gravel of 8mm to 4.6mm size of approved quality as ordered to packed around the casing/slotted pipe in bore well complete all as specified and directed dy Engineer- in - Charge. |
| 51 | Development of tube well by compressed air with compressor of minimum capacity of 150 PSI and 450 CFM all as specified.Note:- (i) Yield test for the bore well by continuously pumping to determine safe pumping yield to be carried out by contractor at site and necessary report to be submitted.(ii) Testing of water for potability, dissolved solids, physical/chemical and bactorogical testing etc from the govt lab shall be carried out by the contractor all as directed and test report shall be submitted. (iii) The rates quoted shall deemed to include the above provisions. |
| 52 | S & F housing clamp 90 cm long 20 cm wide out of 6 mm thick MS plate for 200mm dia casing pipe with necessary MS Bolts, nuts & washers at ground level in PCC ( 1 : 2 : 4 ) type B1 using 20 mm graded stone aggregate in block all as specified. |
| 53 | M & L for strata sample box of second class hard wood (Hollock / Bijasal ) of size 40cm x 30cm x 20 cm complete all as directed by Engineer - in charge. |
| 54 | M & L for 50 mm bore GI medium grade column pipe in 6 m length with flanged joints duly scewed and welded with pipe suspended in deep well complete with slote for lead, GI flanges, rubber gaskat clamps, bolts, nuts, etc all as required for completion of work. |
| 55 | Supply, laying, jointing/connecting and testing for 80 mm bore steel tubing galvanised medium grade pipe with all fittings, laid in trenches, complete all as specified. |
| 56 | S&F , non return valve cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump as specified as directed. |
| 57 | S&F sluice valve, cast copper alloy, PN 1.6, of size 80 mm dia complete including connecting.all as specified and directed |
| 58 | Supply installation Testing and commissining submersible pump set Electric driven 3 phase, 415 volt, 50 c/s having discharge upto 14000 Lit / hrs at 180 m head 18 stage not less than 15 HP.Make- KSB/Kirlosker/CG. |
| 59 | Supply, install, testing & commissioning of LT panel outdoor type (KIOSK) factory made powder coated paint made of 3 mm thick CRCA sheet, CPRI approved, dust and vermin proof protection, with 200 Amps copper bus bars front opened with locking arrangements mounted on angle iron frame 40x40x6mm , 45cm height from ground level comparising of the following accessories :-(a) MCCB 100 Amp 35 KA rating 4 pole 440 volts-01 No Make-ABB/Legrand/L&T(b) MCB-63 Amps, TPN 440 V, 16 KA-01 No Make-ABB/Legrand/L&T(c) Starter, star delta, fully automatic suitable for 15 HP 3 phase elect motor - 01 No Make-L&T/Havells/AE(d) Digital Amp meter with selector switch & CT 0-50 Amps - 01 No(e) Digital Volt meter with selector switch 0-500 Volts -01 Nos(f) Single phase preventor mini lec VSP-II-01 No Make-Havells/ABB/L&T/BCH/C&S(g) Phase sequance corrector 15 HP motor, 3 phase-01 No Make-Havells/ABB/L&T/BCH/C&S(h) LED Indicator lamp - 03 Nos (RYB)(j) Wiring with suitable size copper conductor cable for LT panel.(k) Power factor correction capictor bottle type, 3 KVAR 3 phase- 01 No Make- Legrand/ABB/EPCOS |
| 60 | S & F 1100 Volts grade submersible cable flate 3 core with copper conductor 10 sqmm stranded fixed to column pipes with suitable clamps jointing material complete. |
| 61 | M&L Earthing complete with galvanised steel earth plate eletrode 60xm x 60cm x6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to galvanised earth strip 25x4 mm by means of bolts, nuts check nuts and washer of galvanised iron or steelupto test point all as shown in electrical plate No 3 of SSR Part-I connected to test point incl PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40mm dia for earth lead protection from earth plate to test point and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion. |
| 62 | M&L for providing cement concrete in foundation, filling and mass concrete all including required from work etc. complete type B-2 1:2:4 for sealing bactorogical treatment/surface all as specified and directed |
| 63 | M&L for connection GI pipe line 80 mm to CI/GI/DI water mains of size 80/100/150/200/250 mm dia with CI/GI joints & fittings and necessary connecting accessories, complete all as specified and as directed. |
| 64 | S&F , analog water flow meter cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump as specified as directed. |
| 65 | Supply, installation, testing and commissioning of maintenance free earth grid (grounding) interconnected two earth electrode of size 76 mm dia x 3 mtr long each. Metal conductor of electrode shall be Cu bounded MS strip of 50x6mm. Cu bounding of MS rod/strip should be min 250 microns. Earth electrode 76 mm dia x 3 mtr long shall be placed in augured bore hole and embadding of interconnected strip shall be cast in high purity electrically conductive granuler material (10 Kg Power Plus Gel + 50 Kg SRIP Compound Bag) having ultra low resistive value of 0.001 Ohm-m. resulting in increase of the effective surface area of the earth grid to lower the earth resistance. Conductive earth enhancing material mixed with cement in the ratio 3:1 which should not leach chemicals into the adjacent soil or or underground water channels and should be in pH neutral range. Earth enhancing material should permanently protect the encased metal components of the earthing system, All hardware like nuts, bolts and washers should be of stainless steel. Electrode should withstand fault current upto 35 KA for 1 second. Electrodes top terminal be sealed permanently packed with conductive concrete and test link of Cu bonded MS/copper of size 50mm x 6mm x 100 mm shall be taken out to connect the equipment. Test certificate of NABL laboratory shall be submitted by the contractor. Making RCC pit and cover including brazzing of all the joints upto the test point complete including taking out/dismantling old unserviceable conventional earthing accessories, strip, pipe, test point etc complete all as specified and and as directed by Engineer-in-chargeMake :- Powertrac/Elancrete/ Vasconite/Pinac(Avon Eartning)Note - (a) Main earthing lead from earth electrode to equipment upto 7.5 mtr.(b) Funnel with watering pipe GE med grade 20mm dia (ISI Marked) and lugs, charcoal and salt as required.(c) GE protection pipe of size 15mm dia light grade 7.5 mtrs. |
| 66 | S & F Copper strip 20 mm x 3.15 mm with saddles and fixing screws etc for down conductor complete all as specified and directed. |
| 67 | Supply and Fixing ESE Lightening Conductor ASLA-60 with protection Level-I of Model-ESEONE including with external lightening event counter with following technical specifications complete all as specified and as directed by Engr-In-Charge. Make : AIDITEC (SPAIN)/ AKAALTECH/ VTR INFOTECH/ ARETE POWERTECH/ TRISHA ELECTRICAL(a) Early Stimmer Emission Efficiency - 60 Microsecond(b) Standards should be as per NFC 17 102 (2011)(c) Lightening current with stand test = 100 KA of 10/350 Microsecond(d) Area Covered 79 RM Radius(e) External Lightening event counter-01 Nos. Make-Virtue/Avon/Acme |
| 68 | Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and scrwed including 3 nos. 8 mm dia. 25 mm long hex. Head screw |
| 69 | Supply and fixing high mast GI pole 6 RM Length and 58 mm dia for mounting of ESE to raise the height of LC including with Adjustable clamps-03 Nos, U Clamp 6MM-12 Nos, Hook fastners-03 Nos, GI Stay Wire-15 RM and GI Ancor Fastners-04 Nos Complete all as specified and as directed by Engr-In-Charge. Make : Powertrac/Akaaltech/Arete/VTR/Trisha .Note : The rates quoted by the contractor for this item shall be deemed to include the rates of all fixing clamps, fastners and GI Stay wires and No additional payment shall be made on account for the same. |
| 70 | M&L PCC (1:2:4) type B1 using 20mm graded stone aggregates as in foundation foundation of poles etc including weathering slightly roundded or chamfered angle and throating necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. |
| 71 | M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surface without using complete all as specified and directed. |
| 72 | M & L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in coping for electric poles or for stay assy etc. complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |