| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: PERIODICAL SERVICES AND CAMOUFLAGE PAINTING OF BUILDINGS OF VARIOUS UNITS AT BG, HAMIRPUR & MENDHAR AND REPLACEMENT / REPAIR TO E/M INTERNAL FITTINGS / FIXTURES & WIRING IN UNITS AT MENDHAR UNDER AOR OF AGE BR-I OF GE 881 EWS. Contract No : GE/PNH-109/2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | B/R Portions:-Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 3 | 15mm thick rendering in CM 1:4 on fair faces of brick work & finishing the surface even and smooth without using extra cement, including mixing of water proofing compound complete all as specified and directed. Note:- Supply onlyWPC shall be measured and paid separately. |
| 4 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 5 | 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 6 | 5 mm rendering in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 7 | Applying wall care putty (2mm min thickness) on wall surfaces & smoothening the surfaces with sand paper etc (prepatory to OBD, plastic emulsion/interior/exterior emulsion paint as directed) complete all as specified and directed by E-in-C. |
| 8 | Applying two coats of cement base paint in Camouflage pattern over a coat of primer on walls complete all as specified and directed. Note: Camouflage pattern shall be approved by GE |
| 9 | Applying two coats of distemper oil emulsion over a coat of primer on walls , complete all as specified and directed. |
| 10 | Preparation of new plastered surfaces of ceiling and applying two coats of white wash on ceiling complete all as specified and directed. |
| 11 | Preparation of old plastered or unplastered surfaces of any description and applying two coats of cement base paint in camouflage pattern over a coat of primer, complete all as specified and directed.Note: Camouflage pattern shall be approved by GE |
| 12 | Preparation of old plastered or unplastered surfaces of any description and applying two coat of apex paint in camouflage pattern complete all as specified and directed. Note: Camouflage pattern shall be approved by GE |
| 13 | Preparation of old plastered or unplastered surfaces of any description and applying two coat of OBD in camouflage pattern complete all as specified and directed. Note: Camouflage pattern shall be approved by GE |
| 14 | Preparation of old plastered or unplastered surfaces of wall, applying two coat of 1st quality (ready mixed) acrylic distemper of approved manufactuer, required shade and colour complete all as specified and directed.Note: Camouflage pattern shall be approved by GE |
| 15 | Preparation of old plastered or unplastered surface of ceiling and applying two coats of white wash complete all as specified and directed. |
| 16 | Preparation of old painted surfaces of CGI/PGI roofing sheet and applying one coat of synthetic enamel paint in camoflauge pattern complete all as specified and directed.Note: Camouflage pattern shall be approved by GE |
| 17 | Preparation of old wooden surfaces over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 18 | Preparation of old steel or iron surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 19 | Providing and fixing in true horizontal level 600mmx600mm, false ceiling system hot dipped galvanised steel section, exposed surface with pre-coated capping, main tee of size 24x38mm, having 0.25mm gauge at every 1200mm centre to centre maximum and rotary sttiched cross tee of size 24x38mm having 0.25mm gauge at every 600mm c/c and sub cross tee of size 24x38mm having 0.25 mm gauge at every 1200mm c/c and wall angle of size 19x19mm having 0.35mm gauge fixed to the periphery of the wall. The above grid is suspended at every 1200mm c/c in both directions using 2.0 mm thick pre straightened GI wire, laying calcium silicate fissured pattern semi perforated butt edge ceiling tiles, of size 600mmx600mmx6mm having thermal conductivity K=0.15 W/mOK, having fire performance (BS-476) including taking down old existing ceiling board complete all as specified and directed. |
| 20 | French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with two or more coats. |
| 21 | E/M PORTION:- Taking down carefully copper/aluminium point wiring for light, bell socket power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose, celing fan etc complete all as specified and directed. |
| 22 | M&L for point wiring with two single core 1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of approporiate size and all requisite accessories such as PVC elbow, Tee, collars, bends etc with PVC terminals box& cover for mounting switches, sockets, fan regulator etc complete all as specified and as directed for the following:- |
| 23 | One light/fan point controlled by one switch 6 amp one way complete all as specified and directed. |
| 24 | One light point controlled by two switch 6 amp two way switch complete all as specified and directed. |
| 25 | One 3 Pin, 6 amp socket outlet on same board complete all as specified and directed. |
| 26 | One 3 Pin, 6 amp socket outlet on independent board complete all as specified and directed. |
| 27 | One bell point controlled by one bell push button complete all as specified and directed. |
| 28 | All as per item No. 21 above but with two 2.5 sqmm size cable as phase and neutral and one 2.5 sqmm size cable as earth continuity for 15/20 amp multipurpose socket outlet on independent board complete all as specified and directed. |
| 29 | Piano Type switch ,modular, 6 amp single pole flush type one way complete all as specified and directed. |
| 30 | Piano Type switch ,modular, 16 amp single pole flush type one way complete all as specified and directed. |
| 31 | Switch socket outlet modular type 3 pin 5 amp flush type complete all as specified and directed. |
| 32 | Switch socket outlet modular type 3 pin 15 amp flush type complete all as specified and directed. |
| 33 | Modular step type fan regulator , electronic type, 120 watt 2 module complete all as specified and directed. |
| 34 | Modular white cover plate with frame for 3 module complete all as specified and directed. |
| 35 | Modular white cover plate with frame for 4 module complete all as specified and directed. |
| 36 | Modular white cover plate with frame for 6 module complete all as specified and directed. |
| 37 | Modular white cover plate with frame for 8 module complete all as specified and directed. |
| 38 | Modular metal flush box 3 module all as specified and directed. |
| 39 | Modular metal flush box 4 module all as specified and directed. |
| 40 | Modular metal flush box 6 module all as specified and directed. |
| 41 | Modular metal flush box 8 module all as specified and directed. |
| 42 | Piano Type switch , 1 way, 6 amp, flush type complete all as specified and directed. |
| 43 | Piano Type switch , two way, 6 amp, flush type complete all as specified and directed. |
| 44 | Piano Type switch , 1 way, 16 amp, flush type, single pole complete all as specified and directed. |
| 45 | Socket outlet 2 in 1, 3 pin 6 Amps, flush type complete all as specified and directed. |
| 46 | Socket outlet 2 in 1, 3 pin 6 Amps and 16 Amps, flush type complete all as specified and directed. |
| 47 | Ceiling rose, 3 phase,bakelite 65x50mm two or three therminals complete all as specified and directed. |
| 48 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 49 | Bell push flush type switch, 230 volt complete all as specified and directed. |
| 50 | Electric bell ding dong type 230 volts AC supply complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply and fix in repairs Electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed. |
| 52 | Supply and fixing in repair Inverter LED light fittings, 1x20 w LED, 230 V complete with all accessories internally per wired including lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours and connecting up with PVC insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed. |
| 53 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 54 | Supply and fixing in replacement recess/surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36 watt incl connecting up twin core twisted flexible copper conductor cable complete with all accessories as specified and directed. Note:- The LED rod should have PF>0.9, input voltage 90-300V, Ip-20, LM 80 stranded luminaries efficiency 100 lumen/watt |
| 55 | Supply and fixing in repairs LED bulk head 10W with pressure die cast aluminium housing high efficient LEDs and enclosed with milky diffuser IP 66 protection, PF 0.9 CRI> 70, L70 with all accessories pre wired and connecting with twin core twisted flexible copper conductor cable complete all as specified and directed. |
| 56 | S&F in repair gate light fittings, outdoor type, high power LED 25 Watt, pre-wired with suitable for pole mounting complete with all accessories all as specified and directed. |
| 57 | S&F in repair of non metallic rigid PVC conduit of size 25mm dia incl all accessories use for fixing of conduit on wall and ceiling etc, complete all as specified and directed. |
| 58 | S&F in replacement of PVC casing caping of size 25 mm incl all fixing accessories, complete all as specified and as directed. |
| 59 | S&F in replacement of flexible PVC conduit of approved quality of size 25 mm dia bore with fixing materials complete, all specified and as directed by Engineer-in-charge. |
| 60 | Supply only copper Flexible twin twisted wire, PVC, 10/0.2 gauge complete all as specified and directed by Engr-in-Charge. |
| 61 | Supply only tape insulation 20mm x 25 mtrs, complete all as specified and directed. |
| 62 | Supply and fixing in repair Plug top 15 Amps, 230Volt, 50Hz complete all as specified and directed. |
| 63 | Supply only flexible LED Strip light with adapter, water proof, multi-color, suitable for 230V, 50Hz complete all as specified and directed. |
| 64 | Sub main wiring with single core cable 2 x 4 sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade drawn through PVC casing/caping 25 mm dia ISI marked fixed on wall/ceiling, alongwith 1x2.5 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly , complete all as specified and directed.Note:-Two runs of 4sqmm cable alongwith one run of 2.5sqmm PVC insulated copper conductor as earh wire incl casing caping shall be measured as one unit. |
| 65 | Sub main wiring with single core cable 2 x 6 sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade drawn through PVC casing/caping 25 mm dia ISI marked fixed on wall/ceiling, alongwith 1x4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly , complete all as specified and directed.Note:-Two runs of 6 sqmm cable alongwith one run of 4sqmm PVC insulated copper conductor as earh wire incl casing caping shall be measured as one unit. |
| 66 | Distribution board double door type(for incoming MCCB & outgoing MCBs) TPN 4 way vertical type sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and as directed. |
| 67 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 4 Ways, Double Door (IP-43), with neutral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 68 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door (IP-43), with neutral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 69 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 12 Ways, Double Door (IP-43), with neutral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 70 | S&F in replacement MCCB four pole 415 Volts, 100 A, 25 KA complete all as specified and directed. |
| 71 | S&F in replacement MCB three pole and neutral isolator 415 Volts, 63 A, 25 KA complete all as specified and directed. |
| 72 | S&F in replacement MCBs 5-40 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB , complete all as specified and directed. |
| 73 | S&F in replacement MCBs 5-40 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB ,complete all as specified and directed. |
| 74 | S&F in replacement MCBs isolator 40-63 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed. |
| 75 | Earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6) type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : The Earth result should be less than 3 ohm and the result will be checked in presence of MES Rep. |
| 76 | S&F in replacement plug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified. |
| 77 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 4 sqmm solid aluminium conductor, complete all as specified and directed |
| 78 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 sqmm solid aluminium conductor, complete all as specified and directed |
| 79 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm solid aluminium conductor, complete all as specified and directed |
| 80 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 16 sqmm solid aluminium conductor, complete all as specified and directed |
| 81 | Taking out of ceiling/exhaust fan/Air circulator fan from AGE E/M store yard/Site and transport to reputed workshop for rewinding the fan starter with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord for putting fan in serviceable condition including refixing the same after carrying out necessary repairs to original place all as directed by Engineer-in-Charge of following sizes:- (Bushes, shafts, bearings, capacitors, flexible wires,painting etc. shall be measured and paid separately) |
| 82 | Ceiling Fan (1200/ 1400 mm) size of any make |
| 83 | Exhaust Fan of 230/300mm size of any make. |
| 84 | Replacement of capacitor 4.0/2.5 mfd capacity (condenser) of exhaust and ceiling fans complete all as specified and directed. |
| 85 | 3 core PVC flexible copper conductor cable(cord) of 0.5 Sqmm complete all as specified and directed. |
| 86 | GM bushes for ceiling/exhaust fans of various sizes complete all as specified and directed. |
| 87 | Blades for ceiling fans of 1200mm/1400mm size of any make complete all as specified and as directed. |
| 88 | M.S. clamps for hanging ceiling fan with nuts, checknuts and bolts 2\\" x 3/8\\" : 02 Nos. including rubber rings(reel) for hanging ceiling fans complete all as specified and as directed. |
| 89 | Steel body exhaust fan 300 mm sweep single phase 230 volts including flap and fixing arrangement as per site requirement complete all as direcected. |
| 90 | S&F in repairs energy efficient LED street light fitting (beamer), 45W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, minimum 50000 burning hours, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, 90W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 91 | S&F in replacement street light GI pipe bracket 40mm dia 1.50m length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc |
| 92 | LED lamp 9 watt complete all as specifed and directed. |
| 93 | LED lamp 7 watt complete all as specifed and directed. |
| 94 | Ceiling fan 1200mm sweep with 3 blades, electric driven single phase 240 volt 5 str rated, BEE energy effecient and connecting up including provision of cable from ceiling rose or connector to fan to make it functional complete all as specified and directed. |
| 95 | Disconnecting electric & water connection to geyser of cap 25/50/35 ltr, taking down, from existing position, dismantling and inspecting all the parts, for its serviceability, cleaning of serviceable parts i.e. Heating elemet, base assy, connecting lead, thermostat, electrical contact, electric wiring, indicators, safety valves etc and refixing, replacement of unserviceable parts, re assembling, remounting, reconnecting with electrical & water connectionn and testing complete. Note:- (i) The defective parts to be replaced shall be measured and paid separately. (ii)Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item. |
| 96 | Heating element 2.0 KW, ISI marked with gasket suitable for as existing size, type and make of geyser under repair, complete all as specified and directed. |
| 97 | Heating element 1.5 KW, ISI marked with gasket suitable for as existing size, type and make of geyser under repair, complete all as specified and directed. |
| 98 | Thermostat ISI marked suitable for existing make of the geyser under repair of cap 50/25 /35 Ltrs., compelte all as specified and directed. |
| 99 | Indicator lamp as per existing make and size, complete all as specified and directed. |
| 100 | Geyser safety valve (pressure release valve) for the exsiting make & capacity of geyser, complete all as specified and directed. |
| 101 | Geyser pipe connection heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature for existing geyser complete all as specified and directed. |
| 102 | Aluminium/cromium type flexible connection heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature for existing geyser complete all as specified and directed. |
| 103 | Inner tank made out of steel sheet conform to IS suitable for 25 ltrs capacity of geyser of different makes vertical type all as specifie and directed |
| 104 | Inner tank made out of steel sheet conform to IS suitable for 35/50 ltrs capacity of geyser of different makes vertical type all as specifie and directed |
| 105 | Supply and fixing in replacment of non return valve made out of brass fixed in veritcal complete all as specified & directed. |
| 106 | Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. |
| 107 | New base assembly with inlet and outlet pipe made out of steel base plate with gasket and proper size of nuts, bolts and washer etc suitable for 25 ltrs capacity of geyser complete all as specified and directed. |
| 108 | New base assembly with inlet and outlet pipe made out of steel base plate with gasket and proper size of nuts, bolts and washer etc suitable for 35/50 ltrs capacity of geyser complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |