| 1 | EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I |
| 2 | Extra for hard soil do……..do……. |
| 3 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume) |
| 4 | Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering, taxes and royalty all complete as per building specification and direction of Engineer In charge |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Centring and shuttring do……….. Fdn. |
| 10 | P.beam |
| 11 | Coloumn |
| 12 | Chajja |
| 13 | Brick work in designation 75B brick with cement mortar (1:6) in Foundation with approved quality of coarse sand of requisite F.M. (2.5 to 3.0) washed and screened with raking out joints to 12mm depth curing,scaffolding and its removal wherever required including royalty and all taxes etc. complete job as per specification and direction of E/I.(5.2.6) |
| 14 | Providing designation 75B Brick work in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction E/I. |
| 15 | Providing 6mm. cement plaster (1:4) in ceiling with clean coarse sand of F.M. of 1.5 including cost of screening curing with all leads and lifts of water, Scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 16 | Providing 12mm. cement plaster (1:6) with clean coarse sand of F.M. 1.5 including cost of screening curing with all leads and lifts of water, Scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 17 | Providing 12mm. cement plaster (1:3) with clean coarse sand of F.M. 1.5 including cost of screening curing with all leads and lifts of water, Scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 18 | Providing 125mm thick reinforced designation 100A brick work in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening, scaffolding, raking out joints to 15mm depth curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction E/I. |
| 19 | Providing D.P.C.(1:2:4) curing, taxes and royalty all complete as per building specification and direction E/I. |
| 20 | Providing and fixing fan hooks of 16mm.dia M.S. bar 1meter long ,bent to required size and shape , placed in position and fixed in R.C.C .Salb/ beam at the time of casting all complete as per building specification and direction of E\I. (where materials is not supplied by the deptt.) |
| 21 | Supplying ,fitting and fixing collapsible gate approved size and make, properly fabricated approved size and make. properly fabricated with vertical double channels 20x10x2mm. at 100mm. centers and braced with M.S. falt diagonals 20x3mm. with top and bottom rail of T.iron 40x40x6mm. with 38mm. dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming cost of red oxide paint carriage hoisting and taxes all complete as per building specification and direction of E/I. |
| 22 | Supplying ,fitting and fixing M.S. grill made of 20x6mm. M.S. flats as per approved design and drawing fillet welded and finished smooth, carriage of grill to work site, hoisting per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 23 | Supplying ,fitting and fixing 20 gauge G.C.I. sheet gate fitted on M.S. angle frame of size 60x60x6xmm, including cost of fabrication , with haskal and dommy duly fixed in C.C.(1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 24 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)8 mm dia |
| 25 | 10 mm dia |
| 26 | 12 to 16 mm dia |
| 27 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible |
| 28 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 29 | For StairProviding and laying vitrified floor tiles for step of stair complete step tiles & have bullnose, Anti and self embossed line. Size of Tile 1200x300 mmx15 mm |
| 30 | Providing and laying 6mm. precast white glazed tiles in walls over 12mm. cement mortar (1:3) and jointed with gray cement slurry, flush pointed with white cement including rubbing , pollshing and cost of curing, taxed and royalty all complete as per building specification and direction of E/I. |
| 31 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene |
| 32 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately |
| 33 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid With float glass panes of 5 mm thickness (weight not |
| 34 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete |
| 35 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 36 | Providing one coat of red lead primer………do……..do…..e/i |
| 37 | Providing two coats of ready mix paints.. do ... do.....e/i |
| 38 | Providing and applying white cement based putty 1 mm thick do…………..do…………………e/i |
| 39 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 40 | Finishing walls with premium acylic smooth exterior paints all complete as per building specification and direction of E/I. |
| 41 | Providing rain water pipe...... do..... do....... |
| 42 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion |
| 43 | Shoe 4 110mm dia |
| 44 | Single Tee with door |
| 45 | Making Plinth protection do………………….do……..e/i |
| 46 | Providing and laying vitrified Cool Roof tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 154557-2007 / 15013006, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. Its solar reflective index ( SRI ) value should be above 78. complete. Size of Tile 300x300 mm x10 mm thick. Parking Tiles (industrial Tiles) |
| 47 | Carriage of MaterialsSand- Lead 20 km |
| 48 | Stone chips- Lead(110P+5K) km |
| 49 | Bricks- Lead 15 km |
| 50 | Cement :- (lead- 10km) |
| 51 | Steel :- (lead- 10km) |
| 52 | Electrical WorkWiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular type switch, phenolic laminated sheet, suitable size PVC/G.I box etc.as |
| 53 | S/F power plug wiring in pvc conduit with 2x 4 sq.mm witch connection, painting etc,as required |
| 54 | Wiring for Circuit/submain wiring in pvc along with earth wire with the followceing sizes pvc insulated copper conductor, single core cablein surface/recessed pvc conduit as required.2x 1.5sq.mm+1x 1.5 sq.mm earth wire |
| 55 | 2x 2.5sq.mm + 1 x 2.5 sq.mm earth wire |
| 56 | 2x 4.00 sq.m +1x 4.00 sq.mm earth wire |
| 57 | Supplying and fixing suitable size GI box with modular plate insulated copper conductor, single core cablein surface/recessed pvc conduit as required. |
| 58 | Supply and fixing following size of pvc conduit including connection etc as required 25 mm PVC conduit |
| 59 | Supplying and fixing following moudular type switch /socket on the exiting switch box /cover 5/6 amps switch |
| 60 | 5/6 amps socket |
| 61 | 15/16 amps switch |
| 62 | 15/16 amps socket |
| 63 | 1 or 2 module boxes,base $ cover plate |
| 64 | 4 module boxes,base $ cover plate |
| 65 | 6 module boxes,base $ cover plate |
| 66 | 8 module boxes,base $ cover plate |
| 67 | s/f moduler type electronic fan regulator |
| 68 | S/F moduler typeblanking plate |
| 69 | S/F 2 pin 5 amp celling rose |
| 70 | S/F batten holder |
| 71 | Installation,testing and comissioning of celling fan including connection with 1.5sq mm FR PVC insulated, copper conductor single core cable etc. as required. |
| 72 | S/ F following way single pole MCB DB6 way double door |
| 73 | S/F 5 amps to 32 amps MCB D Bsingle pole |
| 74 | providing and fixing of 1200 mm dia celling fan |
| 75 | providing and fixing of T5 x 28 w box type tube fixture |
| 76 | S/F change over |
| 77 | Cost of Air Conditinor 2 ton A/c |
| 78 | Sanitary and Plumbing WorkSupplying and fixing IWC pan all complete as per specifi-cation and direction or Engineer-in-Charge. 450mm longI.W.C. |
| 79 | supplying and fixing flat back urinal as per specification and direction of Engineer-in-Charge600mmx350mm |
| 80 | Supplying and fixing wash hand basin all complete as per specification and direction E/I. |
| 81 | Supplying all tools and labours and cutting chajja,cornice,for laying pipe all complete as per specification and direction of E/I |
| 82 | Cutting drain widthwise above GL for laying pipe all complete as per specification and direction of E/I |
| 83 | Making holes in wall |
| 84 | Earth work in excavation for laying R.C.C.pipe |
| 85 | Earth work in back filling all complete as per specification and direction of E/I |
| 86 | Labour for Laying NP2R.C.C.Pipe150mm dia pipe |
| 87 | Supplying all tools and labours for constructing inspection chamber all complete as per specification and direction of E/I |
| 88 | supplying and fixing wall face PVC pipe specification and direction of Engineer-in-Charge |
| 89 | supplying and fixing wall PVC Fitting specification and direction of Engineer-in-Charge coupler 110mm |
| 90 | Single tee with door 110x110x110 |
| 91 | Single tee with door 110x110x110 |
| 92 | Bend 110mm |
| 93 | supplying and fixing PVC pipe clip specification and direction of Engineer-in-Charge 110 mm |
| 94 | supplying fitting and fixing male ended brass bib cock all complete as per specification and direction of E/I |
| 95 | CP brass towel rail 20mmx600mm with bracket container |
| 96 | supplying fitting and fixing PTMTliquid soap container all complete as per specification and direction of E/I |
| 97 | supplying fitting and fixing towel ring all complete as per specification and direction of E/I |
| 98 | supplying fitting and fixing gun mrtal gate valve all complete as per specification and direction of E/I 25mm dia |
| 99 | supplying fitting and fixing brass bib cock all complete as per specification and direction of E/I, 15mm |
| 100 | supplying fitting and fixing brass stop cock as per specification and direction of E/I 20mm dia |
| 101 | supplying fitting and fixing brass long body bib all complete as per specification and direction of E/I 15mm dia |
| 102 | supplying fitting and fixing extension nipple all complete as per specification and direction of E/I |
| 103 | Providing and placing on terrace ( at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and the base support for tank 1000 lit capacity |
| 104 | Providing and fixing cpvc pipe20mm dia |
| 105 | 25 mm |
| 106 | Septic TankEarth work in excavation in foundation Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I |
| 107 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads including cost of materials labour, royalty and taxes all compete as per building specification and direction E/I. (Mode of measurement – Compacted volume) |
| 108 | Providing designation 75 A one brick flat soling joints fitted with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I. |
| 109 | Providing P.C.C. (M-150) (1:2:4) in foundation with approved quality of stone chips 20mm. to 6mm .size graded and clean coarse sand of F.M. 2.5to3 including screening mixing cement concrete in mixer and placing in position vibrating curing taxes and royalty all complete as per building specification and direction of E/I. |
| 110 | Providing designation 75A Brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, to 15mm depth curing, taxes and royalty all complete as per building specification and direction E/I. |
| 111 | Providing 12mm. cement plaster (1:3) with clean coarse sand of F.M. 1.5 including cost of screening curing with all leads and lifts of water, Scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 112 | Providing R.C.C. (M-200) (1:1½:3) in roof slab (Cover slab) with approved of stone chips (20mm.to 6 mm size ) graded and clean coarse of F.M.2.5 to 3 including screening centering shuttering, mixing cement concrete in mixer and placing in position vibrating striking curing (but excluding the cost of reinforcement and royalty all complete as per building specification and direction of E/I. |
| 113 | Providing Tor steel reinforcement of 10 to 12 mm. dia bars as per approved design & drawing drawing including carriage of M.S. rods(Straight of in coils ) to work slte. Cutting , bending and binding with annealed wire cost of wire. removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 114 | Centring and shuttering |
| 115 | Carriage of Materials(i) Sand ( Lead- 20 km) |
| 116 | (ii) Stone chips- Lead(110P+5K) km |
| 117 | (iii) Brick ( Lead- 15 km) |
| 118 | Submerssible Pump workDrilling of Tube Well in all kinds of soil 125 MM Dia Drilling upto 30 mtr Depth below G. L. |
| 119 | Drilling beyond 31.00 mtr upto 60 mtr below G. L. |
| 120 | Supplying all materials, labour equipment for lowering 125 mm dia UPVC casing pipe |
| 121 | Supplying all tools , equipment and labour and doing washing ,flushing and development of drilled tube well |
| 122 | Supplying labour and equipment including 125mm dia G.I.Cap All complete as per specification & direction of E/I |
| 123 | Supplying all materials, labour equipment for lowering 125 mm dia UPVC casing pipe |
| 124 | Basic Rate of 32mm G.I. Pipe in 3 mtrs lenth (medium) with seamless socket |
| 125 | Supplying all tools , equipment and labour and Lowering 32 mm dia G.I. Pipe |
| 126 | Supply Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283 pump shall be suitable |
| 127 | Supplying , Flate flexible submersible cable with ,copper conductor ,PVC insulated and PVC sheathed as per IS 70983 core 4 sq. Mm |
| 128 | D. L. O. Starter with SS Enclosure with 380/415 Volt coil as per IS 3914 |
| 129 | Cost of Library Purpose 3 Seater Study Chair |
| 130 | Cost of Library Purpose 2 Seater Study Chair |
| 131 | Cost of Library Purpose 6 Seating Capacity Study Table |
| 132 | Cost of Library Purpose 4 Seating Capacity Study Table |
| 133 | Cost of Library Purpose Steel Almirah/ Dlass Door /Book Self Almirah half cut Double Doors / Glass Doors , Colurs- Grey/ White- Blue 5 Shelves (Size- 72''x36''x17'') |
| 134 | Supply & Installation of CCTV Camera Set |
| 135 | Supply & Installation of Inverter Set 1000+Microtek / V- Gaurd/ Luminious Set |
| 136 | Supply & Installation of Battery - Exide- IT 850 (230AH) |
| 137 | Cost of office Table |
| 138 | Cost of office Chair |
| 139 | G.S.T. @ 18% |
| 140 | Labour Cess @ 1% Please Enable Macros to View BoQ information |