| 1 | Surface excavation n exc 30 cm deep & avg 15 cm and getting out in hard / dense soil complete all as directed. |
| 2 | Excavating over areas n exc 1.5m in depth in soft / loose soil and getting out complete all as specified and directed. |
| 3 | Excavating over areas n exc 1.5m in depth in hard / dense soil and getting out complete all as specified and directed. |
| 4 | Excavating over areas exc 1.5m but n exc 3.0m in depth in hard / dense soil and getting out complete all as specified and directed. |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed. |
| 6 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 7 | M & L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 8 | M & L for plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 9 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 10 | M&L for hard core of broken stone or boulder, gauge n exc 63mm deposited spread and leveled in layers n exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 11 | M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed |
| 12 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 13 | S&F TMT bars 5 mm to 10mm dia as in stirrups / spacers / binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | M&L for PVC water bar 1000 x 230 x 5-6 mm thick shall be embedded in RCC construction joint including necessary jointing, cutting, fixing in position complete including all leads and lifts all as specified and directed. |
| 15 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in foundation, footing, mass concrete, foundation beam, plinth beam and base for column complete all as specified and directed. |
| 16 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 17 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 18 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in slab supported on wall ,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 19 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in wall, retaining wall and like any thickness above top of footing including attached pillasters and buttresses complete all as specified and directed. |
| 20 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in chajja complete all as specified and directed. |
| 21 | Use & waste for flat formwork to sides of concrete foundations, footings, bases of columns raft and raft beams, sides and soffits if any of foundations and plinth beams and similar work, etc, rough finished surfaces of concrete etc all as specified and directed |
| 22 | Use & waste for flat form work to sides of pillars, posts struts, piers columns and stanchions, square, rectangular or polygonal rough finished surfaces of concrete etc all as specified and directed |
| 23 | Use & waste for flat formwork to sides of concrete beams, cantilevers, bressummers, lintels over 1.5m span and similar work, etc, rough finished surfaces of concrete etc all as specified and directed |
| 24 | Use & waste for flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat surface, rough finished surfaces of concrete etc complete all as specified and directed |
| 25 | Use & waste for flat formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc, vertical or batter, flat surface, rough finished surfaces of concrete etc complete all as specified and directed |
| 26 | Use & waste for flat formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed |
| 27 | Returning, filling in incl spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. |
| 28 | Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. |
| 29 | M & L for full or more brick thick Brick work with AAC bricks of size 600 x 200 x 200mm / , 600 x 200 x 230mm straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 using old size brick complete all as specified and directed. |
| 30 | M & L for one or more brick thick Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 31 | M & L for one or more brick thick Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 using old size brick complete all as specified and directed. |
| 32 | M & L for half brick thick Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 using old size brick complete all as specified and directed. |
| 33 | M & L for rendering 10 mm thick cement plastering on wall surfaces in cement mortar 1:6 on other than fair face of brick-work or concrete surface and finishing the surface even and fair without using extra cement complete all as specified and directed. |
| 34 | M & L for rendering 15 mm thick cement plastering on wall surfaces in two layers (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 35 | M&L for rendering 5 mm thick cement plastering on ceiling surfaces in cement mortar 1:3 on concrete surface, finished the surface even and fair without using extra cement complete all as specified and directed. |
| 36 | Supply only liquid water proofing compound complete all as specified and directed. |
| 37 | M&L for preparing new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 m/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as ecommended by the manufacturer all as specified and as directed (Note : Rate shall be included for necessary scaffolding and safety measures where required at site ). |
| 38 | M&L for preparation of new platered surface of wall and applying two coats of oil bound distemper over a coat of primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfaces complete all as specified and as directed. |
| 39 | M&L for preparation of new platered surface on ceiling and applying two coats of oil bound distemper over a coat of primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfaces complete all as specified and as directed. |
| 40 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 95 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 41 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be measured and paid separately) |
| 42 | S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 43 | S & F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed. |
| 44 | S&F 100mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 45 | S&F 150 mm long Extruded Aluminium alloy handles, cast type, anodised complete all as specified and directed. |
| 46 | S&F steel rolling shutter of 1.25mm thick of lath, gear operated type with bevel gear box and crank handle including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, push pull or manual type complete all as specified and directed. |
| 47 | S&F safety lever lock, mild steel with 4 lkevers for rolling shutter with standard specification complete all as specified and directed. |
| 48 | S&F ball bearing for rolling shutter complete all as specified and directed. |
| 49 | M&L for preparation of newly primed steel surface of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 50 | S&F factory made uPVC white / colour sliding window, area not exceeding 2.00 sqm each, three track made of extruded profiles with wall thickness of 2.3mm (+0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners including necessary Hardware like Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. (Note: (i) The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. (ii) Net Opening will be measured lor payment purpose.) |
| 51 | S&F UPVC ventilator with framework made out of multichamber hollow PVC section DWUF 405 (40x46mm) of sintex or equivalent section of other make as per make list. 3mm thick pin headed glass shall be fixed with frame in the lower section using extruded PVC section having a dimension of 9mm x 14.5mm (GL-19 PVC section of Sintex or equivalent section of other make as per make list ) with EPDM gasket (SPL-003 of sintex or equivalent section of other make as per make list) for both the PVC sections. Mullion of ventilator shall be made up of multichamber hollow PVC section DWUF 406 (63.5x40mm) of sintex or equivalent section of other make as per make list, shall be fixed with EPDM gasket. GL-19 or equivalent section shall be fixed to the three side of DWUF 405 or equivalent and one side of DWUF 406 or equivalent above the centre mulion. Glass panel of aluminium lower set to be fixed to the frame DWUF 405 or equivalent on the top of the ventilator to the glass. DWUF 405 or equivalent and DWUF 406 or equivalent corners shall be mitred cut, joineted and welded with 12mm square guard bar complete all as specified and directed. |
| 52 | S & F 5.50 mm thick, sheet glass, ordinary quality and glazing with oil putty in square n.exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 53 | S & F mild steel frame work such as grills, grating framed guard bar with ends of bars shouldered and / or riveted and similar work confirming to Fe- 410-0 or Fe-310-0 complete all as specified and directed. |
| 54 | S&F 600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers. Complete all as specified and directed. |
| 55 | S&F in vitreous China wash hand basin with pedestal, white, flat back, size 630 x 450 mm including brackets/rock bolt , including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.. |
| 56 | S&F 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.. |
| 57 | S&F 15 mm bore bib tap (Long body) cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 58 | S&F tubular towel rail brass chromium plated 20mm dia, D type, 60cm longbetween flanges complete all as specified and directed. |
| 59 | S&F Health faucet with CP flexible cord fixed on wall alongwith two way brass CP bib cock with handle, screwed down, screwed for iron pipe or female or quarter turn complete all as specified and as directed. |
| 60 | S & F Vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed. |
| 61 | S&F plastic seat cover white for EWC, closed pattern with flat bottom and cover with mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 62 | S & F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 63 | S&F 75 mm dia PVc (SWR) floor trap, plain with grating including pointing with solvent cement complete all as specified and directed. |
| 64 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 65 | M&L 40 mm waste fittings, brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed. |
| 66 | S&F 32mm dia. PVC waste pipe for WHB 60cm long with union complete all as specified and directed. |
| 67 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 68 | S&F soap dish, vitreous China white, approximate size 160x 160x90mm fixed to wall with plug and chromium plated brass screws complete all as specified and directed. |
| 69 | S&F in repairs 15mm dia supirior quality CP angular stop cock with wall flange screwed for iron pipe and fixed, complete all as specified and as directed. |
| 70 | M & L for cleaning of surface thoroughly from dust & dirt and cement slurry @ 3 Kg / Sqm shall be applied thoroughly. Provide 10 mm thick screed bed in CM 1:4 mixed with integral water proofing compound as per manufacturer's instructions, after setting and drying cement mortar, the entire surface of the roof slab shall be cleaned thoroughly to remove all loose particle / dust / dirt particle and applying a coat of hot blown grade bitumen primer grade 85 / 25 @ 1.20 Kg Par Sqm shall be applied over priming surface. APP based polymeric membrane of minimum weight 3 Kg/Sqm and a minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 150gms/Sqm) shall be laid on roof and on vertical surface upto and insert in grooves and packed in CM (1:3) with overlaps in membrane 100mm, The over laps shall be sealed by flames or as per manufacturer's instructions. and finally it will be finished with two coats of bituminous based aluminium paint including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete all as specified and directed. |
| 71 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 72 | M&L for treating along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 73 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per squaremetre of surface complete all as specified and directed. |
| 74 | S&F 20 mm CPVC pipes SDR 11 & plain SDR 11 including all fittings on walls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed. |
| 75 | S&F 25 mm CPVC pipes SDR 11 & plain SDR 11 including all fittings on walls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed. |
| 76 | S & F rotational moulded polyethylene water storage tanks of capacity 1000 litres, double layer construction, ISI marked ,(Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified in SSR Part I and as directed. |
| 77 | S & F 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed. |
| 78 | S & F 25 mm dia ball valves high pressure of PTMT with epoxy coatedAluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 455gms) complete all as specified and directed. |
| 79 | M & L for 20-25mm thick machine cut kota stone slab flooring laid over and including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade including rubbing and polishing complete all as specified and directed. |
| 80 | M & L for 20-25mm thick machine cut kota stone slab as in dado / skirting / riser of step etc as in vertical surfaces laid over and including 10 mm thick bedding layer / backing coat in cement mortor 1:3 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade including rubbing and polishing complete all as specified and directed. |
| 81 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 82 | M&L for glazed ceramic colour tiles in vertical surface of size 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointedin white or colour cement to match the surface with and including 10mm thick backing coat in CM 1:3 complete all as specified and directed. |
| 83 | M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floor finished the surface even and rough to receive the next layer complete all as specified and directed. |
| 84 | M&L for 18 to 20 mm thick granite (jet black colour) tiles machine cut as in floors or cooking platform or in window cill etc jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing with and including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. |
| 85 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and fair without using extra cement including making joints at every 3.00 m interval and every corner with bitumastic filing in proportion of bitumen and sand 1:2 including necessary formwork complete all as specified and directed. |
| 86 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in hard standing, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 including necessary formwork complete all as specified and directed. |
| 87 | S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 88 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 89 | S&F 110mm bore PVC (SWR) bends any type complete all as specified and directed. |
| 90 | S&F 75mm bore PVC (SWR) bends any type complete all as specified and directed. |
| 91 | M&L for septic tank of 25 users complete all as shown in drawings and specified & directed. |
| 92 | M&L for Soak well of 1.20 m internal dia and 3.00 m depth complete all as shown in drawings and specified & directed. |
| 93 | S & F Concrete bed to drain pipes of cement concrete PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) for 150 mm Internal diameter including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 94 | M & L for Precast Reinforced Cement Concrete 1:1.5:3, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately) |
| 95 | M & L for plain cement concrete (1:2:4), type B-1 (using 20mm graded stone aggregate) as in benching of manhole including forming centre channel half round or one fourth section complete all as specified and as directed. |
| 96 | S&F UPVC pipes (SCH-40), 150mm dia including coppler joint complete all as specified and as directed. |
| 97 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and as directed. |
| 98 | Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumifion based fluoropolymer resin coating of approved colour and shade on one face and polymer (Service) coating on other face as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. The fastening brackets of Aluminium alloy 6005 T5/MS with hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics complete all as specified and directed. (Note: (i) Actual area on the external face of the curtain wall with aluminium composite panel cladding shall be measured for payment purpose) |
| 99 | M & L for 25mm thick plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in surface channel or drain finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 100 | S&F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stopvalve boxes, gate stops, parts of ranges, balusters and similar articles n exc 5 Kg each complete all as specified and directed. |
| 101 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrom primer, complete all as specified and directed. |
| 102 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 103 | Rolling and consolidating formation surfaces in cutting with 5 to 8 tonne power roller complete all as specified and directed. |
| 104 | M&L for laying and compacting 150mm thick (Compacted thickness) Granular sub base (GSB) course laid in two layers 75mm thick each layer, grading as per Grade V as specified in Table 400-1 of MoRTH specifications for Road and Bridge works, 2013 over compacted subgrade with natural sand , crushed gravel, crushed stone, crushed slag or combination thereof as per the grading requirement. The materials are mechanically mixed spread and levelled on the subgrade by using motor grader of adequate capacity and rolling with vibratory roller of capacity 80-100 KN static weight for achiving required compaction density of atleast 98% of the maximum dry density, consolidating to required gradient and camber with finished surface tolerance as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed. |
| 105 | M&L for laying and compacting 150mm thick (Compacted thickness) Wet mix macadam (WMM) laid in two layers 75mm thick each layer, grading as per Grade V as specified in Table 400-13 of MoRTH specifications for Road and Bridge works, 2013 manufactured in WMM plant, material comprising of clean crushed graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and consolidating to required gradient and camber with finished surface tolerance as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed. |
| 106 | M&L for sand filling under floors or in foundations including watering and consolidation for cushioning complete all as specified and directed. |
| 107 | M & L Machine pressed precast concrete interlocking paver block any shape prepared with grey cement and pigment of size confirming to IS 15658-2006 of 80 mm thick M-40 Grade laid over sand cushioning layer complete all specified and directed. (Note: Sand cushioning shall be measured and paid in relevant item.) |
| 108 | Supply and fixing black FRP gully drain cover of 600 x 600 mm complete all as specified and directed. Please Enable Macros to View BoQ information |
| 109 | Supply and fixing black FRP gully drain cover of 600 x 600 mm complete all as specified and directed. Please Enable Macros to View BoQ information |