| 1 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe. |
| 2 | Extra on items 1& 2 above, FOR providing CC (6:3:1) base block around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3) mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable FOR alkathene/polythene pipe entry, FOR street light wiring, without Loop Box |
| 3 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1)g) 410 SP - 21 ; 8.5 Mtr., 129.00 Kg. |
| 4 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including filling up the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts |
| 5 | S/F arm bracket of 50 mm bore tubular Pipe (M.S.) of 1. 5 m (5') length for fixing on 75/100 mm pole top including S/F 4 mm thick M.S. plate welded with bolts, nuts & clamps, etc. as required with fabrication work |
| 6 | Erection of Galv. (HOT Dip) Cross arms/ `D... Iron Clamp8).M Supplying & Erection of Galv. `D... iron complete with suitable pole clamp 100mmx114mm porcelain shackle insulator & 19 mm dia Galv. bolts & nuts. incl. painting |
| 7 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 145. Galv. Straining screw 12\\"x5/8\\" dia |
| 8 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.(i)1st coat of aluminium paint over 1 coat of RO priming |
| 9 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.ii2nd coat of aluminium paint over 1st coat |
| 10 | Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision FOR housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision FOR earthing attachment Standard (SKB7) |
| 11 | Fixing only SPN MCBDB (4 to 16 way) on flat iron frame on wall 415V TP/TPN |
| 12 | Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc. Supplying & Fixing of G.I pole cap for suitable size |
| 13 | S/F projected lamp bracket made 50mm dia G.I. Pipe of 1.85 M (6') in length of which 0.9M (3') In projection having .an angle of 105 degree with clamps, bolts, nuts & clamps, etc. as required . |
| 14 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection L&T 6-32A SP |
| 15 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP |
| 16 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab). 10sqmm x 2core |
| 17 | Laying on Wall / surface with Saddles / clamps.(a)Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 18 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab).10sqmm x 4core |
| 19 | Laying on Pole with Clamps.Fixing of Cable along the lentgh of O.H. pole incl. S & F MS pole clamps fabricated from 25 mm x 6 mm MS flat incl. painting |
| 20 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade,Gloster/Havells/Polycab). 4sqmm x 2core |
| 21 | Replacement of following item after listing including removing & Re-fixing of luninaries as required (Materials will be supplied departmentally) Sodium/Metal/MV/70 watt/150 watt/M.L./250watt/ 400watt/M.L.Lamp/Street light LED fittings. |
| 22 | Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required |
| 23 | SUPPLY OF 200W LED FLOOD LIGHT FITTINGS WITH ALL ACCESSORIES |
| 24 | SUPPLY & DELIVERY OF 200 WATT LED STREET LIGHT FITTINGS WITH DRIVER AND ACCESSORIES |
| 25 | SUPPLY & DELIVERY OF 40 WATT LED STREET LIGHT FITTNG WITH COMPLETE ACCESSORIES |
| 26 | Estimated amount |
| 27 | Add: 9%SGST |
| 28 | Add: 9%CGST |
| 29 | 1% LWC Please Enable Macros to View BoQ information |