| 1 | Dismantling all type of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed with in a lead of 75 m. (a) Inground Floor including roof. |
| 2 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 3 | (a) Inground Floor including roof. |
| 4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy. |
| 5 | Sealing of cracks / porous concrete by injection process through nipples/Grouting complete as per Technical specification. |
| 6 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. |
| 7 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). |
| 8 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. |
| 9 | (a) Inground Floor including roof. |
| 10 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roug hening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement . (i) 25 mm thick. |
| 11 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.).Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Streng |
| 12 | Plaster (to wall, floor. Ceiling etc) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of surface includung throating, nosing and drip course concrete where necessary (Ground Floor) i) With 4:1 cement morter (a) 20mm thick plaster |
| 13 | Neat cement punning about 1.5mm thick in wall dado, window sills, floor, drain etc. |
| 14 | M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without ntermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed Inground Floor |
| 15 | Supplying best Indian sheet glass panes set in putty and fitted and fixedwith nails and putty complete. (In all floors for internal wall & upto 6m height for external wall) (i) 3 mm thick (weighing 7.4 kg/Sq.m) |
| 16 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 17 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement designer Ceiling Board (Density > 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.In ground floor. |
| 18 | Ordinary cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and rein- forcement if any, in ground floor as per relevent I.S code. a) Pakur variety |
| 19 | Supplying, fitting & fixing of partly glazed partly panelled or fully glazedsingle leaf Aluminium swing door of all aluminium sections viz doorframe ( top and side frame), shutter( top rail, bottom rail, lock rail, doorvertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, anglescrews etc. including labour charges for fitting and fixing of aluminiumdoor with door spring,/aluminium hinges, glass / Panel board allcomplete as per architectural drawings and direction of Engineer-incharge. [Aluminium door @ 9.0 Kg per Sq.M] |
| 20 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conformingto ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239(Part - I). (A) PVC Pipes 100 mm dia |
| 21 | Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound in conformity with the Municipal Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer–in-charge. |
| 22 | Add GST @ 18% on sum of Sl No-1 to 19 |
| 23 | Add LWC @ 1% on sum of Sl No-1 to 20 Please Enable Macros to View BoQ information |