| 1 | P/F Manhole cover made of angle iron frame of 32 x 5 mm covered with MS sheet 1.66 mm thick along with complete locking arrangement having total weight not less than 40 kgs complete in all respects within all leads and lifts a per complete direction and satisfaction of engineer in charge. |
| 2 | Steel work in single section 45x45x5 mm including cutting hoisting fixing in position and applying priming coat in RS joints n gratings guard wall ladders railing and similar works within all leads and lifts as per direction and satisfaction of engineer in charge comlete in all respects. |
| 3 | Providing & fixing Cast Iron double flanged sluice valve various dia of Kirloskar /KSB/ Kilburn / BHEL/ Leader make of following dia and class PN- 1.6 capable of with standing nominal seat pressure of 16.00kg/Cm2. (as per IS -780-1984 latest with up to date ammendments if any) complete in all respect as per diection and and satisfaction of engineer in charge .100mm |
| 4 | Removal of slips /silt/sand in all kind of soils ( including saturated soils but excluding the boulders and rocky portion requiring blasting up to a distance of 20 mtrs. Disposing off unserviceable material , stacking serviceable material and neatly dressing the surface including deployment of generator and raw water pump for removal of water from the percolation well/ gallery in order to remove the deposited material ) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 5 | Repair of pump house |
| 6 | Demolition of cement concrete in flooring in 1:2:4 (1 cement :2 sand :4 aggregate) including disposal of the waste material complete in all respect as per entire satisfactionn of Engineer in charge.(Pump house Slab) |
| 7 | Demolition of old 15 mm thick plaster in C.M. 1:6 ( 1 cement : 6 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge. |
| 8 | Demolition of old 6 mm thick plaster in ceiling in C.M. 1:3 ( 1 cement : 3 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge. |
| 9 | Cement concrete in flooring in 1:2:4(1 cement :2 sand :4 aggregate) complete in all respect as per entire satisfactionn of Engineer in charge. |
| 10 | 15 mm thick plaster in C.M. 1:3 ( 1 cement : 3 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge. |
| 11 | 6 mm thick plaster in ceiling in C.M. 1:4 ( 1 cement : 4 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge. |
| 12 | Providing and fixing wood paneled glazed or paneled and glazed shutters for doors, windows and clear story 40mm thick windows including bright finished black enameled iron with necessary screws with second class deodar wood 40mm thick. |
| 13 | White washing with lime on undercoated wall surface (Two coats) to give an even shade including thoroughly brooming the surface to remove all dirt dust and other foreign matter. |
| 14 | Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces (two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials. |
| 15 | Painting two coats(excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white. |
| 16 | Painting two coats (Excluding priming coat on new steel and other metal surface with enemal paint brushing into give an even shade including cleaning the surface of all dirt, dust and other foreign matter enemal paint other than white. |
| 17 | P/F 20mm PVC Electrical Pipe (HEAVY) ISI approved as per IS:9537 for surface wiring and internl wiring complete in all respecta as per entire satisfaction of Engineer in charge. |
| 18 | Wiring for sub main wiring with following sizes of PVC insulated conductor single core cable in surface /recessed PVC conduit as required (1.00 sqmm) of finolex /plaza or some ISI make approved make by HPSEB Department complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 19 | Providing and fixing holder for bulbs Anchor/Havells/Syska make complete in all respect as per entire satisfaction of Engineer in charge. |
| 20 | Providing and fixing round electrical fan sheet complete in all respect as per entire satisfaction of Engineer in charge. |
| 21 | Providing and fixing round electrical holder sheet complete in all respect as per entire satisfaction of Engineer in charge. |
| 22 | Providing installation and commissioning and testing of of LED bulbs 20 watts fittings including 90 degree GI bend choke reflector of Bajaj /crompton /Greaves make complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 23 | Providing fixing testing and comissioning of ceiling fan 1200 mm(category - A ) and regulator including wiring of the down rod of standard length (up to 30 cm) with 1.5 sqmm PVC insulated copper conductor single core cable etc. as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects. |
| 24 | Providing & fixing 3 pin socketoutlet on the existing switch box/cover including connection etc. as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects. Please Enable Macros to View BoQ information |