| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7.4) |
| 2 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): From brick work in cement mortar as per direction of Engineer in charge. (DSR 15.8.3) |
| 3 | Brick work with old machine moulded perforated / F.P.S. bricks in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete from ground level upto plinth level in cement mortar 1: 4 (1 cement: 4 coarse sand). complet in all respect. |
| 4 | Earth work in excavation by Mechanical means (Hydraulic excavator) manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and remming of bottoms,lift upto 1.5 m,including getting out the excavated soil and disposal of surplus excavated soil as directed, within lead of 50m. All kinds of soil (DSR 2.8.1-2.36) |
| 5 | Carriage of earth by mechanical transport including loading, unloading Lead of 2 km complete in all respect to the entire satisfaction of the Engineer-In-Charge. |
| 6 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 7 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. :Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). DSR 15.2.2 |
| 8 | Preparation of sub grade including trenching rough dressing of soil, final dressing of earth to give level and camber, watering, rolling with a road roller and compaction of bed complete in all respect. |
| 9 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). as per direction of Engineer-in-charge. (DSR 15.2.1) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) DSR 4.1.10 |
| 11 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) |
| 12 | Brick work with machine moulded perforated F.P.S. bricks of class designation 125 conforming IS : 2222-1991 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete from ground level upto plinth level in cement mortar 1: 4 (1 cement: 4 coarse sand). |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (4.1.2) |
| 14 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.(D.S.R-16.83) |
| 15 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 20mm Cement Mortar 1:3 complete as per the directions of Engineer-In-Charge. |
| 16 | Providing and laying 60mm thick high density factory made cement Concrete interlocking paver blocks of M-30 grade made by rubber mould table type platform and of approved size and design /shape laid in required colour and pattern over and including 20mm Cement Mortar 1:3 complete as per the directions of Engineer-In-Charge. |
| 17 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR 15.60) |
| 18 | Centring and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls: Under 20 cm wide (DSR 5.9.16.1) |
| 19 | 15mm cement plaster of mix: 1:4 (1 cement: 4 coarse sand) to the entire satisfaction of Engineer-in-Charge. (DSR 13.5.1) |
| 20 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Engineer-in-Charge.( DSR 15.56) |
| 21 | Finishing walls with acrylic Smooth exterior paint of required shade:- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm. (DSR 13.46.1) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. (DSR 14.54.1) |
| 23 | Providing and fixing M.S. flat railing having flat size 50x12mm,(2\\"x1/2\\") 4'-0\\" high(3' high above ground level) welded with 2no's M.S. flat 38x10mm horizontally at distancwe 9.5\\" upper and 9.5” from bottom and 1no's M.S. flat 25x10mm on the lower side of top M.S. flat including 8mm M.S. square bars of 45 degree angle at 6\\" center to center between the 2no's horizontally M.S. flat iron. The rates also includes the cost of 2 No. 12mm dia nut and bolts with 2no's M.S. pipe of 19mm dia and 3\\" long imbeded in ceme sleeve piece embedded in cement concrete 1:2:4 block of size 1'-0\\"x0'-9\\"x1'-0\\" and painted with three coats of approved quality paint over one coat of primer complete in all respect to the entire satisfaction of Engineer-in-Charge. |
| 24 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. as required. (DSR 10.25.2) |
| 25 | Providing and fixing metallic fabric consisting of 3\\"x3\\"x3mm size chain linked fencing of M.S wire duly welded or bolted over existing steel frame after dismantling existing damage chain linked fencing of railing. Complete in all respect as per site In-chage Engineer. Please Enable Macros to View BoQ information |