| 1 | SUB HEAD 1 -- DISTRIBUTION WIRINGDistribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) singlecore stranded 'FR' PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit 'FR' (Brand approved by EIC) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed]Average Run -- 9 Mtr. [ 6(d)/E-16 ] |
| 2 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) singlecore stranded 'FR' PVC insulated & unsheathed copper wire(Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded 'FR' PVC insulated & unsheathed copperwire as ECC, to 5A 3 pin flush type plug socket & Piano Keytype switch fixed on MS CRC sheet metal (16 SWG) switchboard cum JB on wall incl. bakelite/Perspex (wall matchingcolor) top cover 3 mm thick as per GS. -- On Board [ 4(a)/E-15 ] |
| 3 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ For 2x 6A S.P.B. & Run. Mtr. ] [ 1(a)/(i)/E-14 ] |
| 4 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ 1(a)/(ii)/E-14 ] [ For 16A D.P.P. & P.P.B. ] |
| 5 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [ 1(a)/(iv)/E-14 ] [ For SPNDB Connection ] |
| 6 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes as per GS.1.5 Sq mm [ NS ] |
| 7 | 2.5 Sq mm [ 9(i)/ F-5 ] |
| 8 | 4 Sq mm [ 9(ii)/ F-5 ] |
| 9 | 6 Sq mm [ 9(iii)/ F-5 ] |
| 10 | 10 Sq mm [ 9(iv)/ F-5 ] |
| 11 | 16 Sq mm [ 9(v/ F-5 ] |
| 12 | SUB-HEAD 2-- PLUGS & SOCKETSSupplying & Fixing CRC sheet metal (16 SWG) JB-cumSwitch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall as per GS. -- 175 mm x 100 mm x 65 mm[ 10(b)/E-4 ] [ 2 x 6A S.P.B. ] |
| 13 | Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover as per GS.- [ 14(a)/E-5 ] |
| 14 | Supply & Fixing 240 V, 6 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections as per GS.-- [ 15(a)/E-5 ] |
| 15 | Supply & Fixing 240V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as requiredas per GS.-- [ 14(b)/E-5 ] |
| 16 | Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections as per GS.-- [ 15(b)/E-5 ] |
| 17 | Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick as per GS.- [ 22/E-6 ] |
| 18 | Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socketwith separate 2 nos. 6 A & 2 nos. 20A Piano key type switch,indicator & 20A switch type SP MCB (Brand approved byEIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick as per GS.- [ 28/E-7 ] |
| 19 | SUB-HEAD 3 -- BDB,PDB,VTPN ETCSupplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc. 32 A, 240 V, DP Changeover Switch (Make-Havells) [ 2(a )/D-1 ] |
| 20 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall as per GS.(2+14) Way Enclosure (607713) [ Make - Legrand ] [ 13/D-9 ] |
| 21 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages as per GS.6 Way Enclosure ( 607716 ) (Make - Legrand) [ 14/D-10 ] |
| 22 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs as per GS. --6-32 A SP MCB [ Make - Legrand ] [ 7/D-6 ] |
| 23 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs as per GS. --40 A DP Isolator [ Make- Legrand ] [ 6/D-5 ] |
| 24 | 63 A DP [ Make - Legrand] [ 6/D-5 ] |
| 25 | 63 A FP |
| 26 | SUB HEAD 4 -- SUPPLY OF CABLESSupply & Delivery of 2 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR ]2 core 10 Sq mm. cable. [ NS ] |
| 27 | SUB HEAD 5 -- LAYING OF CABLESLaying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as per GS. -- [ 2(a)/F-1 ] [ For 2 core 10 Sq mm. ] |
| 28 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damagesas per GS. --From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [ 5(i)/F-3 ] [ For 2 core 10 Sq mm. ] |
| 29 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre as per GS. -- [ 1(a)/F-2 ] [ For 2 core 10 Sq mm. ] |
| 30 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry as per GS.2 core 10 Sq mm. cable gland. [ 7(a)/F-4 ] |
| 31 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS.2 core 10 Sq mm. cable [ 8(b)/(iii)/F-5 ] |
| 32 | SUB HEAD 6 -- FIXING OF LIGHT FITTINGSFixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire as per GS. -- [ 17/C-2 ] |
| 33 | Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required. [ 14(d)/C-2 ] |
| 34 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire as per GS.-- [ 16/C-2 ] |
| 35 | Fixing only lamp. [ 11/C-2 ] |
| 36 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [ 22/D-13 ] |
| 37 | Supplying & Fixing bulkhead light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 200 watts GLS lamp complete set. [ 23/D-13 ] |
| 38 | SUB HEAD 7 -- SUPPLY OF LIGHT FITTINGSSupply & Delivery of Single LED fitting (20 Watt, 230V AC, 50 Hz, 5700-6500K CDL, THD < 10%, built in 2.5 KV SPD) with all accessories and 1 no. polycarbonate LED Tuube light as directed by EIC, Luminious efficacy > 105 & <120 Lumen/watt. The LED luminaves & accessories shall have BEE certification. (Make- Philips/Crompton/Wipro) |
| 39 | Supply & Delivery of Double LED fitting (20 Watt, 230V AC, 50 Hz, 5700-6500K CDL, THD < 10%, built in 2.5 KV SPD) with all accessories and 2 nos. polycarbonate LED Tuube light as directed by EIC, Luminious efficacy > 105 & <120 Lumen/watt. The LED luminaves & accessories shall have BEE certification. (Make- Philips/Crompton/Wipro) |
| 40 | Supply of 9 Watt LED lamp to the lamp point. [ Make - PHILLIPS(Signify), Colour - Cool Day White, Lamp Base - B22, Pin type/Crompton ] [ NS ] |
| 41 | Supply & Delivery of (2' X 2' ) 36 Watt Square shaped Full Glow LED Panel Light fittings, Recessed Mounted, [ Make - Crompton, Model - POLARIS (T), Cat No. - TCR-145-36-57-SL-NWH /Equivalent of Phillips ] [NS] |
| 42 | Supplying & Fixing of Surface type Bell Push Switch of 240 V, 6 Amp (Make - Anchor, Penta, Colour - white, code - 2323) [ NS ] |
| 43 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. [ 20(a)/D-13 ] |
| 44 | Supply & Fixing Ceiling Rose on existing point [ 69/K-2 ] |
| 45 | Supply & Fixing One way circular box & cover on existing point. [ 66/K-2 ] |
| 46 | SUB HEAD 8 -- FIXING OF FANSSupplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages as per GS.-- [ 29/D-14 ] |
| 47 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw as per GS.-- [ 18/(a)/E-6 ] |
| 48 | Lowering down only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required. [NS] |
| 49 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [ 21/(a)/C-3 ] |
| 50 | Supply & Fixing of Down for ceiling fan of required length (14 SWG) from Fan clamp to body with necessary arrangements of nuts, bolts and washers etc. as required as per the direction of EIC. [ NS ] |
| 51 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. [ 21/(b)/C-3 ] |
| 52 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. [ 29/C-4 ] |
| 53 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible as per GS. --23 cm. ( 9 '') [ 28(a)/C-4 ] |
| 54 | 30 cm. ( 12 '') [ 28(b)/C-4 ] |
| 55 | 38 cm. ( 15 '') [ 28(c)/C-4 ] |
| 56 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)For Aluminum, 23 cm. Exhaust Fan ( 9 '') [ 32(a)/D-14 ] |
| 57 | For Aluminum, 30 cm. Exhaust Fan ( 12 '') [ 32(b)/D-14 ] |
| 58 | For Aluminum, 38 cm. Exhaust Fan ( 15 '') [ 32(c)/D-14 ] |
| 59 | Fixing of Timer of Exhaust fan incl. S & F of wodden ply board of size 10\\" X 6\\" X 6 mm. on wall incl. fixing of SP MCB on this ply board incl. necy. arrangements as required incl. necy. connections by fixing with suitable sizes of screw, washers, nuts etc. |
| 60 | Supply and Delivery of 20-240V AC, 1 - Phase, Analog Timer for Exhaust fan ( Make - SELEC, Cat No.- 800xC ) |
| 61 | SUB HEAD 9 -- SUPPLY OF FANSSupply of ceiling fans complete with all accessories having the following Model / Cat No. [ Make - Crompton Greaves/USHA/Orient ] 1200 mm Sweep AC Ceiling Fan, Colour - White, with safety wire & PS 2 Capacitors. [ NS ] |
| 62 | Supply & Delivery of 220-240 Volt AC, 50 Hz, 1-Phase [ Make :- Crompton, Model - SSTORM2 PLUS WF/USHA/Orient, Full Metal Body type, Sweep 450 mm Colour - Black Chrome ] Wall Mounting Fan. [ NS ] |
| 63 | Supply & delivery of Exhaust Fans complete with all accessories having the following Model/ Cat No. [ Make - EPC Heavy Duty ]9 '' ( 230 mm ), Speed - 1370 RPM [ NS ] |
| 64 | 12 '' ( 300 mm ), Speed - 920 RPM [ NS ] |
| 65 | 15 '' ( 380 mm ), Speed - 920 RPM [ NS ] |
| 66 | Supply & Delivery of 220-240 Volt AC, 50 Hz, 1-Phase Air Circulator Heavy Duty Pedestal Fan [ Make :- Crompton, Model - 600 mm. ACVORTEX24PF, Full Metal Body, Oscillating, Sweep 500 mm, Colour - Black ] [ NS ] |
| 67 | SUB HEAD 10 -- MISCELENEOUSDismantalling of the existing old electrical wiring from existing old MCBDBs, dismantling of existing damaged LED Tube light fittings - fixtures, Ceiling fans, Batten lamps, Exhaust fans, old cables, damaged loop boxes, damaged main switches etc. and mending good the damages by necy. plaster works to these all damaged areas as per the requirement of site situation as per the direction of EIC. [ NS ] |
| 68 | Making holes on RCC ceiling 125 mm depth having dia of following sizes :125 mm depth, 50 mm dia [ 9(b)/E-3 ] |
| 69 | Additional charges for cutting the RCC Road and mending good the damages as to original finish after laying the cable through the existing GI Pipe protection as per size given below -- 40 mm dia [ NS ] |
| 70 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. -- 40 mm dia [ 11(c)/F-6 ] |
| 71 | SUB HEAD 11 -- EARTHINGExcavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [ 1(a)/G-1 ] |
| 72 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI - Medium GI Pipe [ 2(a)/ G-1 ] |
| 73 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall as per GS. [ 4(b)/G-2 ] |
| 74 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [ 5(c)/G-3 ] |
| 75 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid G.I. wire -- No. 4 SWG GI wire. [ 5(a)/(i)/G-2 ] |
| 76 | Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36cm X86.36cmX46cm deep(below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside)CI hinged inspection cover of size 36.56cmX35.56cm with locking arrangement ,GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [ 3(a)/G-2 ] |
| 77 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode. [ 3(b)/G-2 ] Please Enable Macros to View BoQ information |