| 1 | Earth work excavation for foundation and depositing on bank for refilling within an initial lead of 10.00 m and an initial lift of 2.00 in hard stiff clay. Stiff black cotton soil, hard red earth, sales, murrams, gravel, stoney earth, earth mixed with small sized boulders and hard gravelly soil and except hard rock requiring blasting including shoring, strutting, bailing water wherever necessary and all other incidental charges etc., complete as directed by departmental officers as per S.S.20B |
| 2 | Plain Cement Concrete 1:4:8 mix, (one part of cement, four part of sand and eight part of aggregate) mix using 40mm ISS HBG metal from approved Quarry including cost and conveyance of all materials and all labour charges for mixing, laying, compacting and curing the concrete and other incidental charges etc., complete. as per standard specification 28 V,VI S25 |
| 3 | Brick Work in Cement Mortor 1:5 Mix (one cement, five sand) using new best II Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications |
| 4 | Plastering in C.M. 1:5 mix (one part of cement and five part of Sand) 12mm tk including mixing and finishing to a well smoothened surface, watering cost and conveyance all materials and all labour and other incidental charges and other incidental charges etc., complete. as per standard specification TNBPSS 56,57 |
| 5 | Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc., Complete |
| 6 | Painting two coats with Emulsion paint of approved colour and quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 7 | Drilling of 150 mm dia Bore well in hard rock area to any required depth as decided by the Departmental officers including Transportation from one place to anothr place with in Tamilnadu State by direct method using contractor's rig tools at the site shown by the Departmental Officers including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification 0 to 150 M |
| 8 | 151 to 180 M |
| 9 | 181 to 210 M |
| 10 | 210 to 240 M |
| 11 | Supply and erection of 200 mm dia PVC Casing Pipe of approved quality to require depth including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 12 | Supply and deleivery of Three Phase SUBMERSIBLE PUMPSET for Bore well WITH ISI MARK IS 8034/2002 WITH PANEL BOARD of duty condition 100 lpm x 250 m etc complete as per standard specification |
| 13 | Supply and delivery of UPVC ,PVC pipes and specials including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification 40 mm UPVC Pipe |
| 14 | 32mm GI coupling (Havey) |
| 15 | 32mm GI Elbow |
| 16 | 32mm GM Gatevalue |
| 17 | 32 mm GI union |
| 18 | MS Bore Cover |
| 19 | MS Clamp Set |
| 20 | 2.5 Sqmm 3 core Flat cable |
| 21 | 63 mm PVC Pipe |
| 22 | 63 mm PVC Bend |
| 23 | 32 mm NR Valve |
| 24 | Laboar charges for the erection of submersible pumpset in Borewell including fixing jointing submersible cable with proper clamps up to starter to required depth ande also fixing of riser pipes to the recquired depth valves erection clamps,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter,Ammeter,Three pilot (indicating) lamps capacitor single phasing preventor,Water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days |
| 25 | Supply and fixing of 32 Amps DP Switch of 500V with metal clad with fuse and neutral (Side Handle) on suitable TWBoard with PWD Earthingincluding cost and conveyance of all materials to site and all labour charges etc complete asper std. specifications. (SD 143) |
| 26 | Supply and run of 2 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V on 7/20 GI bearerwire for service connection mains of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification (SD 66) |
| 27 | Laying of PVC Pipe into trench to require slope including cost and conveyance of all materials and labour charges to site etc., complete |
| 28 | Refilling the Trench with excavated earth including cost and conveyance of all materials and labour charges to site etc., complete |
| 29 | Geophysical Survey Charges Please Enable Macros to View BoQ information |