| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 3 | Filling of Avilable Soil |
| 4 | Supply and Filling of local earth Upto 8 Km Cartage . |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 6 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos E.C. 20% with 1% concentration |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources). |
| 8 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, includingnecessary excavation, levelling & dressing & finishing the top smooth. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 10 | Suspended floors, roofs, landings, balconies and access platform |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 13 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 14 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 15 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 16 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Note :- 1)The cement content considered in this item @ 330 kg / cum. Excess / less cement used as per design mix is payable / recoverable separately.2) Fly ash confirming to grade I of IS 3812 )Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456-2000 in the items of and RMC.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 17 | All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 18 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.HYSD/Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 23 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold gs or with dash fasteners of required dia & length (hold fast lugs ) (Hold Fast Shall be Paid Sepratelly)second class teak wood |
| 25 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows,With 5 mm Glass fixing with butt hinges of Butt hinges and necessary screws shall be paid separately)separately, all complete as per direction of Engineer-in-charge. (Note:-requiredsize with necessary screws, excluding panelling which will be paid for second class teak wood 35mm shutter |
| 26 | Extra For Providing ISI Marked Stainless steel but Hinges instead of M.S. pressed but hinges bright finished of required size with necessary scews .(Shutters area to be measured ) |
| 27 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with with vertical grains or cross bands and face veneers on both faces offrame of 1st class hard wood and well matched teak 3 ply veneering shutters.35 mm Thick |
| 28 | Extra for Providing Lipping with 2nd class teak wood bettens 25mm minimum Depth on all edges of flush door shutters (over all area of door shutter to be measured .).. |
| 29 | Providing 45X5 mm Flat iron Hold Fast 40 cm long including fixing to Frame with 10mm Dia. Bolts nuts and wooden plugs ,and embending in cement concrete block 30X10X15 cm 1:3:6 Mix ( 1 cements :3 coarse sand :6 graded stone aggegates 20mm nominal sizes ) |
| 30 | Providing and fixing bright finished brass tower bolts (berrel type ) with necessary screws etc. complete .200X10 mm |
| 31 | 150X10 mm |
| 32 | Providing and fixing bright finished brass door latch with necessary screw etc . Complete .250X16X5 mm |
| 33 | Providing and fixing bright finished brass casement stays (strights peg type )with necessary screws etc. complete .250mm weighting not less then 280 gms. |
| 34 | Providing And fixing brightfinished brass hendles with screws etc. 125 mm |
| 35 | Providing and fixing brights finished brass hanging type floor door stopper with ecessary screws etc. Complete . |
| 36 | Providing And aluminium Die cast body tubuler type universal hydrolic door closer (Heavy Brand logo wth ISI ,IS :3564 embossed on the body ,door weight up to 35 kg and door wedth up to 700mm )with necessary accessories and screws etc. complete . |
| 37 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 38 | 15mm Thick Cement Plaster Mix With Cement Mortar 1:4 (1 Cement :4 Coarse Sand )1:6 (1 cement : 6 fine sand) |
| 39 | 12mm Thick Cement Plaster Mix With Cement Mortar 1:4 (1 Cement :4 Coarse Sand ) |
| 40 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 41 | Distempering (First Coat ) with oil bound distemer of approved brand and manufacture and of give an evan shade over and including a priming coat with cement primer of approved brand and manufacture such as burrger ,J&N ,Shalimar , Asian paints after throughly brushing the surface free from mortar droping and other forgein matter and also including of all supply of all material , labour , tools &plants etc required for proper completion of the Work . |
| 42 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : |
| 43 | Varnishing with varnish of approved brand and manufacture: Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. |
| 44 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqm |
| 45 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - Exposed face machine cut and table rubbed with rough backing 40 mm thick |
| 46 | White sand stone - exposed face fine dressed with rough backing .70 mm thick |
| 47 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 48 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securingadjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2coarse sand), including making the necessary chases. |
| 49 | Providing and fixing machine cut / hand dressed Red Sandstone work of 70 mm thickness in required shape and size, in various rchitectural elements at all levels, including supplying, fabricating, transporting, Loading and unloading ,hoisting and fixing in position, complete as per rawings and irections of Engineer-in-Charge.The stone shall be fine-grained, reddish or uff coloured, locally available, of approved quality, free from cracks, avities, stains, veins and other defects, and of uniform shade for each individual element.The work shall include manual carving, machine carving, ornamental work, traditional work, figure work of any type and any size, CNC cutting, moulding, etc., as required. Carving and moulding workmanship shall be of superior quality and shall conform to approved samples.Fixing shall be done true to line, level and plumb using approved cement slurry with atching pigment, epoxy adhesives such as Akemi (Germany), Ardex Endura, MYK Laticrete or equivalent approved make, and shall include necessary brass clamps, pins and dowels (brass clamps and pins to be measured and paid separately).The rate shall include all scaffolding, staging, tools and plants, hoisting arrangements, cutting, shaping, finishing, fixing, alignment, making good, cleaning, curing and protection, complete in all respects, as directed by the Engineer-in-Charge. |
| 50 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Makrana white second quality |
| 51 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 52 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All With average thickness of 120 mm and minimum thickness at khurra as 65 mm.above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 53 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 54 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good thewall etc. complete. |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mmgap for thermal expansion.Bend 87.5°(110mm bend) |
| 56 | Shoe (Plain)(110mm shoe) |
| 57 | Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shadeCarving and Fixing of Traditional Design Red SandStone Chhtri (Dom Structure) as per architectural drawing the works includes supplying top quality red sand stone hand carving of arches chhajja or Chhatri or top dome the structure shall be installed on a prrepared base including all necessarymaterial , scafffolding ,lifting ,transporting from workshop to site and final polishing .etc T&P Complete. |
| 58 | Supply and laying 160 mm dia HDPE (PE-100) (PN-6) pipe ISI marked along with alll accessories for duct in mediun as per drawing and technical specification complete as per instruction of engineer -in-charge . |
| 59 | Providing and fixing 3D brass letter signage for display of project name, made out of solid / sheet brass of approved grade and thickness, CNC / laser cut to required font, profile and size, with smooth finished edges, complete as approved.The letters shall be mounted on suitable aluminium / MS backing support frame or directly fixed on gate structure, at required height and alignment, using stainless steel/brass fasteners, studs, anchors, spacers, etc., complete.The work shall include surface finishing such as polishing / brushing / antique finish / lacquer coating to protect against weathering, including cleaning, alignment, fixing, and making good the surface.The item shall be executed as per approved drawings, size, finish and directions of the Engineer-in-Charge, including all materials, labour, tools & plants, scaffolding and incidental works, complete in all respects.T&P complete. |
| 60 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR-16.69) |
| 61 | Electrical WorkWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C |
| 62 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 63 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 64 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 65 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 66 | Supply an dFiixing of Factory wired integral LED Floodlight With luminaires with die casthousing built with driver set with suitable for 140 to 150watt conformingto IP66 protection complete in all respact.Cat -AA |
| 67 | Supply and Fixing of LED tube Light with Batten suitable for up to 1x22 Watt LED fitting Tube Light including tube on surface complete in all respact.Cat -AA |
| 68 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way Double door |
| 69 | Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete withconnections, testing and commissioning etc. asrequired. 25 amps |
| 70 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required.Single pole |
| 71 | Supplying and fixing single pole blanking plate in theexisting MCB DB complete etc. as required. |
| 72 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 Amp Switch |
| 73 | Supplying and fixing DP sheet steel enclosure onsurface/ recess along with 25/32 A 240 V \\"C\\" curveDP MCB complete with connections, testing andcommissioning etc. as required. |
| 74 | Supplying, installation, testing and commissioning of wall mounted fan of sweep size 450 mm, heavy duty, oscillating type, with aerodynamic blades, suitable for 230/240 volts, 50 Hz, single phase AC supply, complete with down rod/bracket, clamps, nuts & bolts, rubber bush, safety guard, including connection with existing wiring, earthing, making good the damages etc. as required. Make: Havells or equivalent approved make |
| 75 | Supply and burying of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, outer Dia 50 mm, inner Dia 25 mm, terminal Dia 12 mm, outer G.I. pipe of 16 SWG and inner G.I. pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm × 3 mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P.P.W.D., & C.P.R.I. Certified. |
| 76 | Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required. |
| 77 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 78 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 79 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 80 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 81 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 82 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Please Enable Macros to View BoQ information |