| 1 | ST Pole 11 m Long SP-55 |
| 2 | Stone Pad |
| 3 | 11 KV Pin Insulator |
| 4 | 11 KV GI Pin with Nut |
| 5 | Plinth for 250/400 KVA Transformer |
| 6 | Fancing for 250/400 KVA Transformer |
| 7 | Shifting of 25, 63 & 100 KVA transformer |
| 8 | Chemical Earthing for transformer |
| 9 | G I Strip 35×5 mm |
| 10 | 11 Kv KLPE AL cable 1×70 sqmm |
| 11 | Shifting of 250 & 400 KVA Transformer |
| 12 | AI Lugs 70 sqmm |
| 13 | 11 kv fuse set |
| 14 | Danger Board with Clamp nut & bolt |
| 15 | alluminium Paint |
| 16 | Red Oxide Paint |
| 17 | Stay Complete |
| 18 | Earthing Complete |
| 19 | Concreting of Stay |
| 20 | Concreting of Poles |
| 21 | Muffing of Pole (0.880 cum each) |
| 22 | 11 KV XLPE Cable 3×185 sqmm (DBL CKT) |
| 23 | Cable jointing kit 33kv, 3×185 sqmm (out Door) |
| 24 | Cable jointing kit 33kv, 3×185 sqmm (S/T) |
| 25 | G I Pipe 6\\" dia with Clamp |
| 26 | Holding clamp for GI pipe & Cable |
| 27 | Cable Laying charges along with cost of Bricks & sand |
| 28 | MS Top Channel (100x50X2240) |
| 29 | Clamps with bolts & Nuts for Channel |
| 30 | T- Off Channel 125×65×1300 mm |
| 31 | Number Plate |
| 32 | Transformer base angle |
| 33 | LT Distribution Boards (Type A-5) for 100 KVA Transformer |
| 34 | LT Distribution Boards (Type A-3) for 250 KVA Transformer |
| 35 | LT Distribution Boards (Type A-2) for 400 KVA Transformer |
| 36 | LT Distribution Boards (Type B-5) |
| 37 | Steel structure for panel Type B -5 |
| 38 | LT Distribution Boards (Type C) |
| 39 | Steel structure for panel (Type A-2, A-3 & A-5) |
| 40 | Steel structure for panel Type C |
| 41 | Earthing Complete (Type B-5 & Type C) |
| 42 | LT XLPE Cable AL. 1X400 sqmm |
| 43 | LT XLPE Cable AL. 1X240 sqmm |
| 44 | LT AL Armoured Cable 1X150 sqmm |
| 45 | Alumium Lug 400 sqmm |
| 46 | Alumium Lug 240 sqmm |
| 47 | Alumium Lug 150 sqmm |
| 48 | Alumium Lug 95 sqmm |
| 49 | Alumium Lug 10 sqmm |
| 50 | Alumium Lug 16 sqmm |
| 51 | PVC Tape(Diffirent Colour) R,Y,B |
| 52 | Double Comprecing Brass Glands 400 sqmm |
| 53 | Double Comprecing Brass Glands 240 sqmm |
| 54 | Double Comprecing Brass Glands 150 sqmm |
| 55 | Double Comprecing Brass Glands 95 sqmm |
| 56 | Double Comprecing Brass Glands 10 sqmm |
| 57 | LT cable XLPE 3.5*150 sqmm |
| 58 | LT cable XLPE 3.5*95 sqmm |
| 59 | LT service cable XLPE AL Armoured 2*10 sqmm |
| 60 | LT service cable XLPE AL Armoured 4*16 sqmm |
| 61 | Cable Laying charges along with cost of bricks & sand |
| 62 | Consumer's service Cable Laying Charges |
| 63 | Road restoration charges for pucca road crossing |
| 64 | Road restoration charges for foot path side |
| 65 | End termination of LT XLPE AL Armoured for diffirent Size with material |
| 66 | Erection of Steel structure panel Type A-5,A2 & A3 |
| 67 | Erection of Steel structure panel Type B-5 |
| 68 | Erection of Steel structure panel Type C |
| 69 | Resealing for Consumer's Meter |
| 70 | Cartage, Erection & Dismantling Charges @ 15% on the above Items. Please Enable Macros to View BoQ information |