|
| 1 | MATERIAL Rigid P.V.C. pipes with one loose coupler for every 6.0 mtr. Length and solvent cement accordingly to technical specification IS Marked I.S.No. 4985/2000 with latest amendments and duly I.S.I. certification marked & CIPET tested. 315 mm.dia Class-I (0.25 MPA) |
| 2 | 200 mm.dia Class-I (0.25 MPA) with Coupler |
| 3 | 140 mm.dia Class-I (0.25 MPA) with Coupler |
| 4 | 140 mm.dia Class-II (0.25 MPA) with Coupler |
| 5 | Rigid P.V.C. Accessories of Class-II (0.4 MPA) according to Technical specification as per relevant IS Code with latest amendment & duly I.S.I. certification marked & CIPET tested. 315 mm.dia F.T.P. with Metallic flange |
| 6 | 200 mm.dia F.T.P. with Metallic flange |
| 7 | 160 mm.dia F.T.P. with Metallic flange |
| 8 | 200 mm.dia 60̊ Bend |
| 9 | 200 mm.dia 90̊ Bend |
| 10 | 140 mm.dia 600 Bend |
| 11 | 140 mm.dia 900 Bend |
| 12 | 200 x 140 mm.dia Reducer |
| 13 | 160 x 140 mm.dia Reducer |
| 14 | 200 mm.dia Equal Tee |
| 15 | 140 mm.dia Equal Tee |
| 16 | 200 mm.dia End Cap, class-III |
| 17 | 140 mm.dia End Cap |
| 18 | 315 mm.dia Extra Coupler |
| 19 | 200 mm.dia Extra Coupler |
| 20 | 160 mm dia Extra Coupler |
| 21 | 140 mm.dia Extra Coupler |
| 22 | 150 mm.dia Flexible PVC Hose for Suction & Delivery line ISI marked IS-15265 |
| 23 | MS ACESSORIES:-150 mm.dia C.I Sluice Valve (ISI Marked IS-14846) |
| 24 | Galvanized MS Flanged Pipe ISImarked-IS: 1239, Galv-IS 4736150 mm dia |
| 25 | 150 mm.dia Alfa Alfa Valve (Nipple Type as per IS 210) |
| 26 | 150 mm.dia 900 G.I Bend(Both end flanged ISI Marked IS 1239) |
| 27 | 150 mm.dia 900 (with priming) G.I Bend(Both end flanged ISI Marked IS 1239) |
| 28 | 150 mm.dia MS Tail Piece One end Flanged other end grooved. |
| 29 | 150 mm.dia non return valve |
| 30 | GI Set for quadruped (For Major RLI Scheme) All Material ISI Marked |
| 31 | Nuts & Bolts :- 20 mm x 80 mm |
| 32 | 20 mm x 100 mm |
| 33 | 16 mm x 80 mm |
| 34 | 16 mm x 65 mm |
| 35 | 16 mm x 50 mm |
| 36 | Foundation Bolt :- For Distrubution Chamber (20 mm.dia x 375 mm.long) |
| 37 | For Motor driven Pump Sets (8 Nos.) |
| 38 | Compresed Asbestos fibre jointing for Quadruped Set (for raised surface of Flange as per IS-6392/71) 500 mm.dia (Table-5) |
| 39 | Solvent cement conforming to I.S. No. 14128/94 with latest amendments, Medium Bodies. |
| 40 | Rubber Insertion, duly, reinforced 5 mm.thick 2 plies as per I.S.No.-6392 with latest amendments.300 mm.dia (Table-17) |
| 41 | 300 mm.dia (Table-11) |
| 42 | 300 mm.dia (Table-5) |
| 43 | 200 mm.dia (Table-11) |
| 44 | 200 mm.dia (Table-5) |
| 45 | 150 mm.dia (Table-17) |
| 46 | 150 mm.dia (Table-5) |
| 47 | 125 mm.dia (Table-17) |
| 48 | 80 mm.dia (Table-17) |
| 49 | 150 mm.dia Foot Valve Lather Washer |
| 50 | 150 mm dia C.I Combined tail Piece Both side Grooved |
| 51 | 150 mm.dia MS hose clamp with long nut & bolt |
| 52 | Wooden Sleeper 6\\" x 4\\" x 5' Long |
| 53 | Electrical:- Supply of Electric Motor Pump Set having capacity of 200 cubic meter per hour discharge at 24 Meter total head with UP125/30A Pump. The Motor shall be designed for operation at 415V(=10%), 3 Phase, 50 Cycles per Sec (=5%), A.C. supply 1450 r.p.m. The Motor shall be TEFC shall be ISI marked IS 12615 with latest amendments thereof. The Pump shall be horizontal, single stage, split casing ISI marked IS-6595 with latest amendments thereof. Pump should be directly coupled with Motor and mounted on a common fabricated M.S. Base frame with latest amendments as per IS-9079 |
| 54 | Supply of 200Amp. Main Switch Complete for 25 HP Motors (Switch Fuse Unit TPN ISI Markes IS-60947) |
| 55 | Supply of 63 Amp Main Switch Complete for 25 HP Motors (Switch Fuse Unit TPN ISI Markes IS-60947) |
| 56 | Supply of 16 Amp Main Switch Complete for25 HP Motors (Switch Fuse Unit TPN ISI Markes IS-60947) |
| 57 | 3 Phase Electro Magnetic Star Delta starter For 25 H.P Motor (Motor Controller IS -60947) (BCH make) |
| 58 | Supply of 200 Amp Busbar Chamber |
| 59 | Supply of wooden pannel board of size 6ft. X 4ft. X 1 inch. with 6 Nos. M.S. clamp for Pump House wall mounting |
| 60 | Tools kit comprising Slide wrench set 12\\" long, Ring wrench set, Side spanner set, Screw Driver 1' long, Hammer 500 Gram, Electrical Tester, Combind Pliers, Funnel 8\\" etc. |
| 61 | Pump HouseEarthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. (considering 50 mm clearence) |
| 62 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 63 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 64 | Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety |
| 65 | Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety |
| 66 | Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. For PUMP HOUSE |
| 67 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel ( Other than SAIL/ TATA/RINL) i)For foundation Blocks of Water Distribution System |
| 68 | Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete.a) In foundation & plinth. |
| 69 | Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. b) 20 mm thick with 1:6 cement mortar. |
| 70 | c) 10 mm thick with 1:4 cement mortar. |
| 71 | Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete. |
| 72 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 16 Kg./sq.mtr and above. |
| 73 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or bothfaces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost ofall labour and materials. |
| 74 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) completeA) UPVC Pipes:(i) 75 mm. Dia |
| 75 | Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation. (Payment to be made on the basis of measurement of finished quantity of work) |
| 76 | Priming one coat on timber, plastered surface with synthetic enamel/oil boud primer of approved quality including smoothening surfaces by sand papering etc. |
| 77 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white)(b) On steel surface (Normal gloss).Two coats (with any shade except white). |
| 78 | Supply Fitting fixing of best quality lock & key for door off Godrej make |
| 79 | Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house. |
| 80 | Carriage charge (4%) on every item from Sl. no-61 to 79 Carriage except Item No-61,75 |
| 81 | WTA:- Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. |
| 82 | Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete. |
| 83 | Laying of P.v.C. pipes of different diameters within field trenches in curve /straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge.a) 315 mm dia |
| 84 | b) 200 mm dia |
| 85 | c) 140 mm dia |
| 86 | Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work) |
| 87 | Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. |
| 88 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 89 | Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity. |
| 90 | Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity. |
| 91 | Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 92 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steelI. SAIL/ TATA/RINL (i)For foundation Blocks of Water Distribution System . |
| 93 | Brick work with Ist class brick in cement mortar (1 : 6) . (a) In foundation and plinth. |
| 94 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 95 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster. |
| 96 | Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. Complete. |
| 97 | Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150 mm. dia. ERW pipe. |
| 98 | Fitting and fixing of M.S. / G.I. / C.I.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. a) 150 mm dia sluice valve. |
| 99 | Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site) |
| 100 | Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 140 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete. |
| 101 | Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC. |
| 102 | Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-inCharge. |
| 103 | Carriage charge (4% ) on every item from Sl. no-81 to 102 excluding Sl. No-81,82 & 86,102 |
| 104 | INTERNAL WIRING Fitting of wooden pannel board of size 6ft. X 4ft. X 1 inch. with M.S. clamp on the wall of pump house and made necessary arrangment for fitting fixing the following elctrical equipment including 2 coat of pantigof app.quality as per direction of E.I.C. |
| 105 | Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall63 Amps On angle iron frame |
| 106 | Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall200 Amps On angle iron frame |
| 107 | Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto-Transformer) with Nuts & Bolts fixed on Angle iron frame onwall and making necessary connection with the electrical cables.iii) Star-Delta / Auto-Transformer Starter (Above 15 HP upto 25 HP) |
| 108 | Fixing only MS sheet metal busbar Chamber on angle iron frame on wall. 4 bars, 200 Amps. |
| 109 | Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm.p.v.C.! XLPE insulated & sheathed and armoured Aluminium/Copper Cable fromMeter to incomming TPN Main Switch 1 Terminal.(Brand: Gloster/Havells/Finolex)d) For MAJOR RLI Schemei) 50 Sqmm 3.5 Core Aluminium Cable |
| 110 | Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex)(i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to Bus-bar] |
| 111 | (ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbarto 63 A, TP Main switch and 63 A TP switch to Motor starter] |
| 112 | (iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in32 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor] |
| 113 | Supplying & fixing bulk head light fitting(Havells Make) on wall / Ceilling incl. S&F suitable 100 watts lamp complete with glass wire-guard and holder. |
| 114 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface] (a) Average run 5 mtr |
| 115 | Connecting the equipments to earth busbar including S & F G (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (a) Solid GI wire (iii) No. 8 SWG |
| 116 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe |
| 117 | Supply & Fixing EI danger board on wall 20cm x 30cm ( 8\\" x 12\\" ) |
| 118 | Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger |
| 119 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 120 | Add GST @18% for the item No (61 to 119) on 1215615.67 |
| 121 | cess 1% on for the item No (61 to 120) on 1434426.49 |
| 122 | Quotation chagre (including Supervision Charge & Security Deposite) |
| 123 | ENERGISATION OF RLI PCC POLE 9 MTR. LONG |
| 124 | MS CHANNEL 100 X 50 X6 mm |
| 125 | MS. CHANNEL 75X40X6 mm |
| 126 | MS. ANGLE 65X65X6 mm |
| 127 | MS. FLAT 65X6 mm |
| 128 | GI STAY SET HT (1830 X 20 MM) WRKG LD-7900 KG |
| 129 | PORCELAIN GUY INSULATOR HT |
| 130 | GI STAY WIRE 7/3.15 MM |
| 131 | GI STAY SET LT (1680 X 16 MM) WRKG LD-5100 KG |
| 132 | PORCELAIN GUY INSULATOR LT |
| 133 | GI STAY WIRE 7/2.5 MM |
| 134 | G.I EARTH SPIKE 1833 X 20 MM |
| 135 | G.I WIRE 5MM |
| 136 | G.I WIRE 4 MM |
| 137 | 11KV POLY COMP. WH FTTG PIN INSULATOR 5KN |
| 138 | 11KV POLY COMP. WH FTTG DISC INSULATOR 45KN |
| 139 | COMPOSITE H/W FITTGS FOR 30/50 MM COND |
| 140 | ISL 11 KV 200A TPGO |
| 141 | COND ACSR RBT 50 SQ.MM |
| 142 | 1.1 KVPVC CABLE 50 SQ.4C. AL CABLE |
| 143 | DTR 63 KVA 11/0.433 KV |
| 144 | 11KV V BRACKET FOR PCC POLE 9M LONG |
| 145 | 11KV TOP ADOPTOR FOR PCC POLE 9M LONG |
| 146 | 11KVABCABLE 3C X 70 + 1C16+ 1CX 50 SQMM |
| 147 | D IRON CLAMP 3'' X 3.5 \\" |
| 148 | PORCELAIN SHACKLE INSULATOR 3\\" X 31/2\\" |
| 149 | LT DISTRIBUTION KIOSK FOR 100 KVA TRNF |
| 150 | GI TURN BUCKLE |
| 151 | SURVEY OF 11 KV OH LINE |
| 152 | SURVEY OF L & MV OH LINE |
| 153 | SURVEY OF LT AB CABLE 3C X 70 + 1C16+ 1CX 50 SQMM |
| 154 | ERECTION OF SINGLE PCC POLE 9 MTR.LONG WITH FITTINGS |
| 155 | ERECTION OF DOUBLE PCC POLE 9 MTR WITH FITTINGS |
| 156 | ERECTION OF SINGLE PCC POLE 9 MTR.LONG ( L & MV) |
| 157 | EXTENSION OF PCC POLE 9 MTR. |
| 158 | GROUNDING OF HT STAY SET COMPLETE |
| 159 | ERECTION OF EARTHING COMPLETE |
| 160 | FIXING OF PIN INSULATOR |
| 161 | FIXING OF DISC INSULATOR |
| 162 | FIXING OF LEAD WIRE 30 TO 60 MTR 2W |
| 163 | STRINGING & SAGGING OF 50 SQ.ACSR(3 WIRE ) |
| 164 | ERECTION OF 63 KVA DTR COMPLETE |
| 165 | MAKING FIXING OF CROSS LACING |
| 166 | FIXING OF TPGO ISOLATOR SET 11 KV COMPLETE |
| 167 | ERECTION OF D.P. S/STN STRUCTURE USING 9 MTR PCC POLE |
| 168 | SUPPLY & EARTHING FOR NEUTRAL POINT OF DTR COMPLETE |
| 169 | FIXING OFMS AND KIOSK COMPLETE DOUBLE SWITCH |
| 170 | GROUNDING OF LT STAY SET COMPLETE |
| 171 | FIXING OFCRADDLE GUARD BRACKET ON D.P |
| 172 | FIXING OF SHACKLE INSULATOR |
| 173 | FIXING OF 3 PHASE S/C. WORK COMPLETE |
| 174 | Add Sundries @ 5% on item no (123 to 150) materials cost i.e. 5% of Rs. 742542.55 |
| 175 | Add GST @ 18% on item no (151 to 173) LABOUR cost i.e. 18% of Rs. 104566.00 |
| 176 | Add CESS @ 1% on item no (151 to 174) AND SL NO 175 Total cost i.e. 1% of Rs. 160515.00 Please Enable Macros to View BoQ information |