| 1 | Construction and fabrication of temporary structure for shoring around work site by supplying Cold Formed Steel Sheet Pilling, Z-Type or U-Type as per IS:2314 1986, up to Amendment No.1 June 2018, structural steel material conforming to Grad Designation E 250 (Fe 410 W), of IS 2062: 2006 having minimum yield strength of 250 N/mm², at worksite including all statutory taxes, duties and incidental charges, having minimum thickness, mass and elastic modulus within the permissible range as shown below; A) for use in all temporary structures e.g., shoring, coffer dams etc. i) Range of minimum thickness (excluding tolerance) at any part in mm (tmin) : 8.0≤ tmin ≤8.5(ii) Range of Mass (Kg / sq.m) : 97.3≤M≤108.60(iii) Range of Section Modulus (cm3) : 1037 ≤Z ≤ 1759 including supply and fixing of ISMB/ISMC supporting steel structures weighing not less than 22.50 kg/m. required for construction of sheet pile wall and Driving of sheet piles, supporting structure etc. by vibro-hammer and carriage of all equipment including cost of material as site as per drawing and direction of the Engineer-in-charge and Extraction of the driven sheet pile and supporting structure carefully by chain pulley block or equivalent arrangement after completion of the work and taking back the sheet pile etc.as salvaged materials complete from the working site by the agency. The cost is inclusive of cost of all materials, labour charges, carriage of materials to site and taking back of extracted salvaged materials all complete in all respect. |
| 2 | Excavation for Structures. Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, removing, spreading or stacking of spoils within a lead of 150 m. as directed and including trimming the sides of the trenches, leveling, dressing and ramming the bottom, and backfilling with approved material complete as per direction of the Engineer-in-Charge.A) In all sorts of soil excluding marshy soil & rocks (soft or hard) by manual means. |
| 3 | a) Depth upto 3 m. i) With pumping out water excluding shoring. |
| 4 | b) 3 m to 6 m depth. i) With pumping out water excluding shoring. |
| 5 | Sand filling in foundation trenches and at the back of abutments, wing-walls etc. with good local sand free from earth in layers not exceeding 15 cm. including inundating each layer by profuse water and poking and ramming layer by layer complete including supply of sand. Quality of sand is to be approved by the Engineer-in-charge.Using : fine sand (Gr-III as per IS: 382-1970) |
| 6 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 7 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 8 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.A) Pakur Variety.Cement: PPC/PSC/OPC(33 Grade). |
| 9 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.A) Pakur Variety. Cement: PPC/PSC/OPC(33 Grade). |
| 10 | Furnishing and Placing Reinforced / Pre-stressed Cement concrete in Super-structure with coarse aggregates of appropriate nominal size and grading, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement and admixtures, as necessary, including labour, cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge and cost for quality control, sampling, testing etc. all complete as per drawing and technical specification including the cost of necessary form work and staging complete. as per drawing and technical specifications. A) RCC Grade M20;I. Using Concrete Mixer;i) For solid slab super-structure;a) Height upto 5m.Note : From durability consideration, the value of minimum cement content and maximum water cement ratio to be considered in the mix design shall be as per the direction of the Engineer-in-Charge. During the execution of the item necessary quantity of approved plasticizers to obtain the desired workability and strength is to be added, cost of which has been incorporated in the rate of the item.Cement : OPC 33 /PSC / PPC. |
| 11 | Plain / Reinforced Cement Concrete in Sub- structure with coarse aggregates of appropriate nominal size and grading, fine aggregate (sand) conforming to proper grading zone, both of approved quality, cement and water reducing admixtures, as necessary, including labour, cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge and cost for quality control, sampling, testing etc. all complete as per drawing and technical specification including the cost of necessary form work and staging complete as per drawing and technical specifications.A) RCC Grade M25;i) Height upto 5m;a) Using concrete Mixer.Note : From durability consideration, the value of minimum cement content and maximum water cement ratio to be considered in the mix design shall be as per the direction of the Engineer-in-Charge. During the execution of the item necessary quantity of approved plasticizers to obtain the desired workability and strength is to be added, cost of which has been incorporated in the rate of the item.Cement : PPC/PSC/OPC33. |
| 12 | Furnishing and Placing Reinforced / Pre-stressed Cement concrete in Super-structure with coarse aggregates of appropriate nominal size and grading, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement and admixtures, as necessary, including labour, cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge and cost for quality control, sampling, testing etc. all complete as per drawing and technical specification including the cost of necessary form work and staging complete. as per drawing and technical specifications. A) RCC Grade M25;I. Using Concrete Mixer;i) For solid slab super-structure;a) Height upto 5m.Note : From durability consideration, the value of minimum cement content and maximum water cement ratio to be considered in the mix design shall be as per the direction of the Engineer-in-Charge. During the execution of the item necessary quantity of approved plasticizers to obtain the desired workability and strength is to be added, cost of which has been incorporated in the rate of the item.Cement : OPC 33 /PSC / PPC. |
| 13 | Supplying, fitting and placing HYSD bar reinforcement in Sub-structure including initial straightening, straightening of coils bars, removal of loose rust (if any), cutting to requisite length bending, binding with annealed wire not less than 1 mm in size and conforming to IS 280 at every intersection hooked and bent to correct shape and placed on forms etc. including cost of black annealed wire and cost of loading, unloading, carriage of all steel materials complete as per drawing and technical specifications and direction of Engineer-in-charge. Steel material: Tor Steel rods/HYSD bars/TMT bars(SAIL/TATA/RINL)(Fe 415/Fe 500/Fe 500D conforms to IS: 1786) |
| 14 | Supplying, fitting and placing HYSD bar reinforcement in Bridge Super-structure including initial straightening, straightening of coils bars, removal of loose rust (if any), cutting to requisite length bending, binding with annealed wire not less than 1 mm in size and conforming to IS 280 at every ntersection hooked and bent to correct shape and placed on forms etc. including cost of black annealed wire and cost of loading, unloading, carriage of all steel materials complete as per drawing and technical specifications.Tor Steel rods/HYSD bars/TMT bars(SAIL/TATA/RINL)(Fe 415/Fe 500/Fe 500D conforms to IS: 1786) |
| 15 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor . (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 16 | 25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone aggregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete. [Bitument to be supplied by the Agency]. Cement: PPC/PSC/OPC-33 |
| 17 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work).A) With earth obtained from excavation of foundation. |
| 18 | Disposal / carriage of excavated earth / materials outside Government land by truck or by any other conveyance over kancha / pucca road including making access for plying the truck or any other conveyance beyond 300 m and upto a distance of 5km from the excavated point including cost of stacking, loading, unloading, transporting, arrangement of land, if required by agency, spreading and levelling as necessary etc. complete. Measurement : By stacks at loading point after deducting voids as per rule. |
| 19 | Brick work with 1st class bricks in cement mortar (1:6). Cement: PPC/PSC/OPC-33 |
| 20 | In foundation and plinth. |
| 21 | In superstructure, ground floor. |
| 22 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. Cement: PPC/PSC/OPC-33 |
| 23 | Flush pointing to brick work in cement mortar (1:4) including raking out joints. Cement: PPC/PSC/OPC-33 |
| 24 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] A) With 1:4 cement mortar.Cement :PPC/PSC/OPC 33. |
| 25 | 20 mm thick plaster. |
| 26 | 15 mm thick plaster. |
| 27 | 10 mm thick plaster. |
| 28 | Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.Cement :PPC/PSC/OPC 33 |
| 29 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In 1st. floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cementA) 35 mm. thick. |
| 30 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. (Measurement will be made on the area of opening covered by the rolling shutter corrected upto 2 decimal.) |
| 31 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge.A) 10-12 Micron thickness Annodizing film Natural white. For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr.and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottomand Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr [Note : for estimate purpose construction wing may consider weight of 2track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M] |
| 32 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.A) 6mm thick coloured / tinted / smoke glass. |
| 33 | Filling the gap in between aluminium frame & adjacent RCC / Brick/Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width. A) Ground Floor. |
| 34 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps.A) Sal : Siliguri. (The quantum shouldbe correted upto three decimals). |
| 35 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.A) 40mm thick shutters with 19mm thick panel of size 30 to 45 cm. i) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. In Ground Floor |
| 36 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately).A) 40mm X 6mm, 250mm Length. |
| 37 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.A) 100mm. X 75mm. X 3.50mm. |
| 38 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.A) 250mm long. |
| 39 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:A) 300mm long x 12mm dia. bolt. |
| 40 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:A) With continuous plate base (Hexagonal/ Round rod).i) 150 mm grip x 12 mm dia rod. |
| 41 | M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed.A) In ground floor. |
| 42 | Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5mm (± 0.2 mm) made out of single piece extruded PVC profile, with mitred cut joint sand joint with 2 nos. of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 mm x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The doorframe to be fixed to the wall using 8 x100mm long anchor fasteners complete, all as per manufacturer‟s specification and direction of Engineer -in- charge. |
| 43 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge.A) In ground floor. |
| 44 | Priming: |
| 45 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 46 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 47 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. |
| 48 | On timber or plastered surface With super gloss (hi-gloss) .A) Two coats (with any shade except white). |
| 49 | On steel or other metal surface With super gloss (hi-gloss). A) Two coats (with any shade except white) |
| 50 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.A) Centre hung ventilators as per I.S. sizes 580 mm. In Ground floor Flash butt welded windows and ventilators |
| 51 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall).A) 3 mm thick (weighing 7.4 kg/Sq.m). |
| 52 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. A) In Ground Floor:i) Two Coat. |
| 53 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specifi cation and as per direction of the EIC. In Ground Floor: A) Two Coats.i) Water based interior grade Acrylic Primer. |
| 54 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.A) In Ground floor (Two Coat). i) Normal Acrylic Emulsion. |
| 55 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.A) Two Coats. |
| 56 | Lime terracing on roof with lime concrete(2:2:7) (2 lime putty / paste : 2 surki : 7 brick khoa ) laid to proper slope, throughly beaten and cured including top finishing, providing ghoondies at junction with parapet etc., shaping and finishing at mouths of rain water pipes, complete as per direction.A) Roof of one storied structure (Payment to be made on surface area of terracing including ghoondies.)i) 75 mm. thick (average). |
| 57 | Providing weep holes in Brick masonry / Plain /Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications. |
| 58 | Bailing out water by pump including all leads and lifts and including making all arrangements for disposal, where continuous flow or seepage of water is encountered and rating of pumps and hours of operation is specifically ascertained as per direction of the Engineer-in-charge. |
| 59 | Making filter with well graded 40 mm down ballasts and laying uniformly behind weep holes, below pitching on bed, side slopes including supply and carriage of all materials to site including preparing bed with earthwork up to 30 cm depth, where necessary and compacting with wooden malllet after laying to achieve designed section as per direction of the Engineer- in - Charge (measurementswill beon finished work /in stack after deducting necessary void).A) Jhama ballast. |
| 60 | Supplying at site and laying in position UV stabilized polypropylene woven geotextile of 430 gsm as filter, as per specification, including cost of preparing the bed, placing the geotextile as per profile with at least 15cm lapping, wherever required and anchorage at top, sewing / welding the overlapped portion, storage and transportation by all means, complete as per direction of the Engineer-in-charge.Note: 1. Payment to be made on measurement of finished surface without lapping, but including anchoring length at top.2. Payment will be made subject to the result of 3rd Party Testing, to be done by the Engineer-in-charge departmentally. |
| 61 | Cast-in-situ cement concrete blocks or lining units as per designed section and specification, in nominal mix proportion 1:1.5:3 (corresponding to M20 Grade) with well graded 20 mm down stone metal aggregate, laid in position by casting in alternative panels or otherwise to keep a gap of 12mm between the adjacent units, over a layer of polythene sheet of thickness not less than 100 um to act as a separator between the bottom surface of the block and the filter material laid below the blocks, including dressing, ramming, shuttering, finishing the exposed surface by trowel without adding any additional cement cement and sand mortar, curing and filling the gaps between the adjacent units by 5.6 mm down coarse aggregate to be compacted properly, with all leads and lifts including supply and carriage of all materials, complete, without the cost of sand cusion / filter.A) Stone Aggregates of Pakur Provisions of the latest Departmental Manual for Liningin Irrigation Canals are to befollowed |
| 62 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directed within a lead of 75 m. A) In ground floor including roof. |
| 63 | Providing and laying Cement concrete Wearing coat M-30 grade with graded stone chips 19mm down including screening and cleaning approved stone chips and sand as necessary laying, finishing complete to camber and grade, curing with water, including cost and carriage of all materials and hire charges for form work including reinforcement complete as per drawing and Technical Specifications vide clause no. 2702 of MoRT&H’s Specification for Road & Bridge Works. |
| 64 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.A) In ground floor. |
| 65 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.A) For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m. |
| 66 | Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary. (Payment to be made on the length of individual lines of wires.) |
| 67 | Compacting earthwork in embankment in layers of 25 cm. by power roller or by any other mechanical means, like tractor driven sheep foot roller/ vibrating plate compactor earth rammer etc., (not at OMC) including necessary watering, labour charges, hire charges of all materials, tools & plants etc. and including cost and supply of all materials complete as per direction of the Engineer-in-charge. (Payment will be made on the basis of Pre-work & Post-work level) |
| 68 | Supplying Jhaw / Eucalyptus bullah piles at work site, including dressing and making one end pointed (iii) 15 cm av. diameter Note: Diameter of pile to be measured at a distance of 1.5m from the thicker end. |
| 69 | Labour for driving Jhaw / Eucalyptus bullah piles by monkey in all sorts of soil including hoisting and placing piles in position, protecting the pile head with iron ring and cutting and shaping heads before and after driving and including hire and labour for necessary driving appliances and all tackles (iii) 15 cm av. diameter Note:1) Payment to be made on the length driven into the ground. Diameter to be measured at 1.5m. from the thicker end. |
| 70 | Supplying, fitting and fixing with iron nails half split bullah wailing pieces and cross pieces etc. complete with cost of all materials and carriage to site (a) Width of thinner end above 10 cm. and less than 15 cm. (i) Jhaw / Eucalyptus |
| 71 | Supplying to site empty cement polythene bags (capacity 50kg) in good condition including stacking, incedental charges etc. all complete (capacity 50 kg) |
| 72 | Labour charges for filling empty cement gunny bag / polythene bag (capacity 50 kg) with all kinds of earth (wet or dry), sand or agreegates(stone / brick) and sewing as done in case of cement bags ,( tying with a knot after filling will not be accepted ) , and stacking within a lead of 30 metre as per direction of Engr-in-charge (cost is excluding the cost of any types of filling materials).NB:- Volume of earth/ sand filled bags should not be less than 0.028cum/ bag. |
| 73 | Dumping in position earth / sand filled gunny / poly bags (capacity 50 kg) within a lead of 30 metre inclusive of all lifts |
| 74 | Removing earth/sand filled poly bags/gunny bags from the channel bed/slope and initially depositing the same near channel bank at a place as directed by the Engineer-in Charge for measurement of Bag.& then disposing off the same at a distance not less than 150 metre from the channel site |
| 75 | Taking out Jhaw / Eucalyptus piles from river bed or from elsewhere including carrying, stacking materials in the nearest stack yard. (a) Up to 17.5 cm. diameter |
| 76 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm.Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part-I.Payment will be made separetly on the basis of actual height based on relevantI.S.Code.(i) For 20 users A) With Pakur variety. (SAIL/TATA/RINL) |
| 77 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary inforcement and shuttering including one 560 mm dia. R.C.C.manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia.(SAIL/TATA/RINL) |
| 78 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (b) With 'S' trap |
| 79 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. ii) 470 mm X 280 mm X 340 mm |
| 80 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approvedquality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. i) 450 mm X 300 mm size |
| 81 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc |
| 82 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer. (a) 500 litre capacity |
| 83 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iv) 1050 mm long |
| 84 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only) (vii) 25 mm dia |
| 85 | Supplying, fitting and fixing bib cock or stop cock (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 86 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) PVC Pipes. (b) For Concealed Work. 15 mm |
| 87 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) PVC Pipes. (b) For Concealed Work. 20 mm dia |
| 88 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) PVC Pipes. (b) For Concealed Work. 25 mm dia |
| 89 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. . (A) Above ground. (ii) 110 mm dia |
| 90 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 91 | Supplying, fitting and fixing shower of approved brand and make. a) ii) Chromium plated round shower with revolving joint (Equivalent to Code No. 541(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 92 | Supplying, fitting and fixing shower of approved brand and make.(c) Chromium plated Hand shower 70mm dia Round Shape Single flowwith Flexible Tube& fittings(Equivalent to Code No. ESH-5512& Model Tropical / Sumthing Special of ESSCO or similar) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail