| 1 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 2 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. |
| 3 | Providing and Laying RCC NP-2 for casing purpose at critical reach of PVC pipe. 500 I/D Pipe |
| 4 | Cutting P.V.C. / H.D.P.E Pipes and specials and chipping or filing the cut surface to a uniform finish complete: - 28.95B(T) 400MM I/D |
| 5 | Providing and Laying of uPVC pipe of 400mm i/d of 2.5kgf including testing etc. complete in all respect as per instruction of Engineer-in-Charge. |
| 6 | Providing Socket of 400mm uPVC for the Tahliwala minor pipeline as per complete in all respect as per instructions of Engineer-in-charge. |
| 7 | Jointing P.V.C. / H.D.P.E Pipes and specials with PVC coupling and cement solvent excluding the cost of PVC coupling and cement solvent, including testing etc. complete in all respect. |
| 8 | Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (125mm) |
| 9 | Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (125mm) |
| 10 | Providing, Laying, fixing & jointing of uP.V.C. 90 deg. bends as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(125mm) |
| 11 | Providing, Laying, fixing & jointing of uP.V.C. equal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (125mm) |
| 12 | Providing and fixing D-Joint confirming to IS codes with latest amendments if any at site of work including loading, unloading, fixing and rehandling if any complete in all respect as per design and PWD specifications and instructionsof engineer in charge. (125mm) |
| 13 | Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (140mm) |
| 14 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge) B. Class PN-1.6 as per IS complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (140mm) |
| 15 | Supply and fixing of Flange tail end 4 kg with flange confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respect as per design, pwd specifications and instructions of Engineer-in-charge (140mm) |
| 16 | Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (140mm) |
| 17 | Providing, Laying, fixing & jointing of uP.V.C. 90 deg. bends as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140mm) |
| 18 | Providing and fixing D-Joint confirming to IS codes with latest amendments if any at site of work including loading, unloading, fixing and rehandling if any complete in all respect as per design and PWD specifications and instructions of engineer in charge. (140mm) |
| 19 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).Class PN-1.6 as per ISI:-400mm i/d Sluice Valves flanged |
| 20 | Supply and fixing of Flange tail end 4 kg with flange conforming to code with latest amendments If any at site of work including loading, unloading and rehandling of any complete in all respect as per design, PWD specifications and instructions of Engineer-in-charge (400mm) |
| 21 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge) B. Class PN-1.6 as per IS complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (200mm) |
| 22 | Supply and fixing of Flange tail end 4 kg with flange conforming to code with latest amendments If any at site of work including loading, unloading and rehandling of any complete in all respect as per design, PWD specifications and instructions of Engineer-in-charge (200mm) |
| 23 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth |
| 24 | Cement concrete 1:2:4- With stone ballast or shingle:-mixing by mechanical means |
| 25 | Cement concrete 1:4:8:- with stone ballast 40mm gauge. |
| 26 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 27 | 12.5 mm thick cement plaster 1:4 Please Enable Macros to View BoQ information |