| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Electrical Executive Engineer Electric Works Division, Dhanbad. Name of Work: Provision of underground service cable for Hostels of BIT Sindri Dhanbad. Contract No: Energy/EWD/Dhanbad/31/2025-26 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | S/L L.T power XLPE insulated PVC sheated (heavy duty) aluminium conductor armoured electric cable for working voltage 1100 volts IS:1554(Part I)1989 Make - havells/polycab/finolex/ or equivalent) 120 sq. mm, 3.5 core |
| 3 | 70 sq. mm, 3.5 core |
| 4 | 35 sq. mm, 3.5 core |
| 5 | 25 sq. mm, 3.5 core |
| 6 | Providing and fixing following TP&N disconnector fuse switch unit in the existing metal board with ISI marked HRC fuses including drilling holes in metal board, making connections. etc. as required. 100 amps, TP&N, HRC |
| 7 | 200 amps, TP&N, HRC |
| 8 | 320 amps, TP&N, HRC |
| 9 | 400 amps, TP&N, HRC |
| 10 | Providing and fixing following capacity busbar chamber with 4 strips of length 300mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body etc. as required. 100 amps |
| 11 | 200 amps |
| 12 | 300 amps |
| 13 | 400 amps |
| 14 | 250 mm x 250 mm brick drain making 250 mm dear with brick drain with cement mortor :6 with 250 mm depthb125 mm apron with one tricle flat soilling plaster CM with running sand filling but excluding earh work in brick drain all complete as reqd. |
| 15 | Making slab for drain of thickness 4\\" and width 0.5 mtr with 10 mm rod quantity of 10 mm rod per mtr slab 4.96 kg providing RCC M 20 (1:1.5:3) nominal mix per mtr slab .05 m3 carrage @ 4% |
| 16 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 17 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 18 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 19 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sq mm direct in ground in the same trech in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm to 95 sq mm (clamped with 1mm thick saddle) |
| 21 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 95 sq mm but not exceeding 185 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 22 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm to 185 sq mm (clamped with 1mm thick saddle) |
| 23 | Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with powder coating with approved shed (Outdoor Type) making PCC plinth and foundation including fitting and fixturing connection ,transpotation upto work site, labour charge etc all complete as required @ 50% of A (7 Nos)1 2.4.8 400 amps, 35 KA, fixed thermal setting 1 Nos 00 amps, 35 KA, fixed thermal setting 4 Nos3 M-873A DIGITAL Volt Mtr. (0-500Volt)- 3 phase class 0.5 1 Nos4 M-873B DIGITAL AMP Mtr. (0-500AMP)- 3 phase class 0.5 1 nos5 M-1452 CT Coil of CT ratio 500/5 IS:2705 part-3 3 nos6 M-1455 LED Indicator Lamp R/Y/B/G 3 nos9 M-688 50 mm X 5 mm copper strips (2 Strip Per Phase) (2.30 Kg/mtr App) for Power Bus 40 Kg9 M-688 25 mm X 5mm copper strips(1.15 Kg/mtr) For For Outgoing Terminal Connection 24 Kg |
| 24 | Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with powder coating with approved shed (Outdoor Type) making PCC plinth and foundation including fitting and fixturing connection ,transpotation upto work site, labour charge etc all complete as required @ 50% of A (1 Nos)1 2.4. 200 amps, 35 KA, fixed thermal setting 1 Nos 100 amps, 35 KA, fixed thermal setting 4 Nos3 M-873A DIGITAL Volt Mtr. (0-500Volt)- 3 phase class 0.5 1 Nos4 M-873B DIGITAL AMP Mtr. (0-500AMP)- 3 phase class 0.5 1 nos5 M-1452 CT Coil of CT ratio 500/5 IS:2705 part-3 3 nos6 M-1455 LED Indicator Lamp R/Y/B/G 3 nos9 M-688 50 mm X 5 mm copper strips (2 Strip Per Phase) (2.30 Kg/mtr App) for Power Bus 32 Kg9 M-688 25 mm X 5mm copper strips(1.15 Kg/mtr) For For Outgoing Terminal Connection 28 Kg |
| 25 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm in the existing RCC/HUME/STONEWARE/METAL pipe as required. |
| 26 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 95 sq mm but not exceeding 185 sq. mm in the existing RCC/HUME/STONEWARE/METAL pipe as required. |
| 27 | Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with powder coating with approved shed (Outdoor Type) making PCC plinth and foundation including fitting and fixturing connection ,transpotation upto work site, labour charge etc all complete as required @ 50% of A (2 Nos)400 amps, 35 KA, fixed thermal setting 1 Nos 200 amps, 35 KA, fixed thermal setting 1 Nos 100 amps, 35 KA, fixed thermal setting 4 Nos3 M-873A DIGITAL Volt Mtr. (0-500Volt)- 3 phase class 0.5 1 Nos4 M-873B DIGITAL AMP Mtr. (0-500AMP)- 3 phase class 0.5 1 nos5 M-1452 CT Coil of CT ratio 500/5 IS:2705 part-3 3 nos6 M-1455 LED Indicator Lamp R/Y/B/G 3 nos9 M-688 50 mm X 5 mm copper strips (2 Strip Per Phase) (2.30 Kg/mtr App) for Power Bus 40 Kg9 M-688 25 mm X 5mm copper strips(1.15 Kg/mtr) For For Outgoing Terminal Connection 30 Kg |
| 28 | 80mm dia Earthing Electrode 2mtr. Length / 80mm dia Earthing Electrode 3mtr. Length / 50mm dia Earthing Electrode 2mtr. Length/50mm dia Earthing Electrode 3mtr. Length & Backfill Compound chemical 4 Bag(per bag 25 KG) |
| 29 | Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. |
| 30 | GST @18% |
| 31 | Labour cess @1% Total in Figures 11580362.12 11580362.12 INR One Crore Fifteen Lakh Eighty Thousand Three Hundred & Sixty Two and Paise Twelve Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |