| Sl. No. | Item Description |
| 1 | Sub Head-I (CCTV) |
| 2 | Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc. :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4,AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30 fps, Sub streams minimum: 720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot..........Cont........... |
| 3 | 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card 10) Recording Management: Format SD, overwrite, storage management, video to NAS device11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 4 | 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens |
| 5 | Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having the following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50dB,Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AC, G.723 4) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable(Main stream: 2MP (1920 × 1080)@25/30 fps Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, .....................cont....................... |
| 6 | 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 7 | 2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens |
| 8 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc. as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 16TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempering, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing........................cont.............................. |
| 9 | 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS and BIS Certified 14) Power Supply: Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.15) Operating Condition: Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses, with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×76821) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode..........................Cont....................... |
| 10 | 23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.29) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection..........................Cont.............. |
| 11 | 30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception D election, People Staying Detection, Violence Detection.36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics(a)16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 12 | Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.(a) 4TB (Terabytes) |
| 13 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.1 Run of cable |
| 14 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD)Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.6U Rack |
| 15 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits 309 DELHI SCHEDULE OF RATES (E&M)-2025 or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.55 inch or larger |
| 16 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 17 | Supplying and fixing of CCTV Cage Protection for Camera with the suitable size of installed camera i/c fixing in the wall/ ceiling, help of screw i/c all accessories complete as required. |
| 18 | Sub Head-II (SOLAR SYSTEM) |
| 19 | Supply, Installation, Testing, and Commissioning of a 15 kW Rooftop Hybrid On-grid Solar Photovoltaic (SPV) Power Plant, including all necessary components Components and Installation:Connections of AC Control Panel including all internal wiring, breakers, protections, and metering. Copper Cabling of appropriate sizes: From PV modules to the DC combiner panel not less than 4 Sqmm tinned single copper DC cables . From AC panel to net meter (as per actual site length). GI Conduits/ Enclosures for all wiring throughout the project. No PVC, CPVC, ABS, or any plastic material will be used for wiring, junction boxes, or cable routing. ESE Type Lightning Arrester with 16 sqmm Copper cable and Chemical Earthing Electrode. Earthing: Chemical copper earthing electrodes shall be provided with GI strip for connection from electrode to equipment’s and structure. Separate earthing systems will be maintained for: ESE Lightning ArrestersDC SideAC SideModule Mounting Structures Surge Arresters and other protective devices as per applicable norms.Foundations and Structures:Hot dip galvanized iron (HDGI at least 80 micron) mounting structures shall be installed suitable for wind speed upto 180Km/h. Walkways will be provided on the high-rise structure to allow safe and convenient maintenance access.Additional Requirements:......................................Cont........................................ |
| 20 | All installation work should comply with relevant safety codes, as per BIS, IEC & MNRE gaidelines national standards, and site-specific conditions or as per direction of Engineer-in-Charge. Testing and commissioning to be carried out in the presence of the Engineer-in-Charge.Any other accessories or components required to ensure a fully operational and compliant solar PV plant shall be included in the scope.CONTINUOUS KW CAPACITY: 15 KW Grid tied system ARRAY CONFIGURATION: As per standard Wattage of modulesOUTPUT VOLTAGE: 415V, 50Hz to be feed into the grid INVERTER EFFICIENCY: 98% and Above having minimum 12 year WarranteeSOLAR MODULEPhotovoltaic (PV) Modules:The solar photovoltaic system shall utilize Top-Con Bifacial N-Type Dual Glass Modules with a minimum power rating of 590 Watt or higher. These highefficiency solar modules shall conform to the latest applicable standards, including IS 14286 / IEC 61215,IS/IEC 61730 Part-1 and Part-2, or any relevant amendments in force at the time of installation.Each PV module must be equipped with a Radio Frequency (RF) identification tag for traceability and monitoring.Key specifications of the modules include:Photoelectric conversion efficiency of ≥ 22.87% Capability to perform satisfactorily under relative humidity up to 100% Operating temperature range: - 10°C to +65°C Designed to withstand wind gusts up to 180 km/h from the rear side of the panel Appropriate interconnection cables shall be provided to ensure secure and efficient connectivity between solar modules. All equipment shall be suitable..........................Cont.................................... |
| 21 | for outdoor installation and comply with environmental and mechanical durability requirements for long-term performance PV Module Specifications and Protections: Appropriate surge protection devices shall be installed at the PV module level to safeguard against voltage spikes and transient surges. Each PV module shall carry a performance warranty guaranteeing: Minimum 90% of the rated output wattage at the end of 10 years Minimum 80% of the rated output wattage at the end of 25 years The modules shall feature: A front cover made of high-transmission (>91%) tempered and textured glass with anti-reflective (AR) coating, having a minimum thickness of 3.2 mm A durable anodized aluminium alloy frame to protect the silicon cells from mechanical damage and environmental exposure Additional technical requirements: Fill factor shall not be less than 0.70 Modules shall be installed at an optimal tilt angle and alignment to ensure maximum annual energy generation Typical open-circuit voltage (Voc): 52.7 V DC Short-circuit current (Isc): Not less than 14.17 A The modules shall be capable of withstanding a high voltage insulation test of 3 kV DC (rms) for 1 minute All modules and associated components shall meet the environmental and electrical safety standards necessary for long-term, reliable performance........................cont............................. |
| 22 | The junction box weather proof fabricated of 2 mm thick CRCA sheet for out door application suitable for roof top SPV panel complete with all accessories, IP 65 String Combiner BOX with required Input and Output, suitable rating DC/AC MCBs and MCCBs, with AC/DC SPDs etc. as reqd. as IEC 62208 or relevant BIS & made of rust proof metal. The terminals shall be connected to copper bus bar arrangement of reqd. size & junction box shall be fitted with cable glands as per reqd. cable size for both incoming & outgoing cable. |
| 23 | MODULE MOUNTING STRUCTUREStructure Design: Low-Height Structure (C-Channel Based): a. Constructed using C-Channels of suitable dimensions with a minimum thickness of 2 mm b. Hot Dip Galvanized for corrosion resistance c. Design as per the attached structural drawing / specification Hot Dip Galvanized Iron (HDGI) pipes for vertical columns c. 2-inch HDGI pipes with a minimum thickness of 2 mm to be used for rafters and purlins in a scissors truss arrangement d. Structure must include a fabricated walkway for safe and convenient access, ensuring ease of maintenance and serviceability All steel/Iron components shall be Hot Dip Galvanized to prevent corrosion and ensure long-term durability in outdoor conditions. The design must comply with relevant Indian standards and sitespecific structural safety norms. The fasteners, nut and bolts should be made of good quality stainless steel (304 Grade).The structures should be designed to allow easy replacement of any module.For Low Rise Structure The minimum clearance of the lowest part of the module structure and the developed ground level shall not be less than 500mm i/c providing appropriate space between row of panels for cleaning the panels & servicing. For High Rise Structure The minimum clearance of the lowest part of the module structure and the developed ground level shall not be less than 10 Ft i/c providing appropriate space between row of panels for cleaning the panels & servicing. PCC foundation as per requirement include in the item. For covering the electrical wires appropriate size covered GI chanels will be used. |
| 24 | DC SIDE 4SQMM CableCables are UV protected with lowest conductor resistance and high mechanical strength for varying weather conditions. Electrolytic grade 99.99% pure copper. Oxygen index more than 30%. Virgin FR grade PVC. Electrolytic multi strand annealed copper conductor. Tin coated. EBXL compound for insulation. UV Protected XLPO compound for sheathing |
| 25 | Power Conditioning Unit (PCU) / Hybrid Inverter – 15 kW15 kW Three-Phase Hybrid Power Conditioning Unit (PCU) / Central Control Inverter shall be provided for solar photovoltaic system operation with battery storage and grid interaction.The PCU shall be capable of converting DC power generated from solar PV modules and battery systems into AC power suitable for feeding into the LT grid and supplying connected loads in grid-connected, hybrid, and backup modes.General Requirements Rated capacity: 15 kW, three-phase Grid-interactive, hybrid type inverter suitable for on-grid, off-grid, and battery-assisted operationSuitable for operation with high-voltage lithium-ion battery systems Capable of seamless transition between grid-connected and backup modes Provision for generator input / AC coupling, wherever requiredTechnical FeaturesEquipped with Maximum Power Point Tracking (MPPT) to ensure maximum energy harvesting from the solar PV array. Minimum two independent MPPT channels, capable of handling string mismatch and partial shading conditions Compatible with DC input voltage up to 1000 V Capable of 100% three-phase unbalanced output, allowing independent phase loading Provision for parallel operation with similar inverters for system expansion and redundancy Built-in energy management logic to prioritize solar, battery, grid, and generator sources Battery Integration Compatible with high-voltage lithium-ion battery banks Battery voltage operating range suitable for hybrid operation Bi-directional charging and discharging with controlled current limits ........................................Cont................................. |
| 26 | Communication with battery management system (BMS) through standard protocols Configurable charging and discharging schedules for peak-shaving and backup operationGrid & Power: Quality Output voltage and frequency fully compatible with local LT grid (415 V, 50 Hz), Power factor adjustable within permissible limits Total Harmonic Distortion (THD) within limits prescribed by relevant standards Anti-islanding protection to ensure safety during grid failure Capability to operate under variable grid conditions common in Indian distribution networks.Monitoring & ControlIntegrated monitoring for: DC input parameters, AC output parameters, Battery status, Faults and alarms, Provision for remote monitoring and data logging, Event and fault history storage for operation and maintenance purposes.Protection & SafetyThe PCU shall include integrated protection systems, including but not limited to: Anti-islanding protection, DC reverse polarity protection, Insulation resistance monitoring, Residual current monitoring, AC over-current and short-circuit protection, Surge protection on DC and AC sidesEnvironmental & MechanicalSuitable for outdoor installation Enclosure protection class minimum IP65. Operating temperature range suitable for Indian climatic conditions. Cooling arrangement through intelligent / forced or natural cooling, as applicable. Wall-mounted type with necessary mounting accessories......................cont.............................. |
| 27 | Standards & ComplianceThe PCU shall conform to the latest applicable IEC / IS standards, including but not limited to: IEC / IS 61683 (Efficiency measurement), IEC 60068-2 series (Environmental testing), IEC 61727 / IEC 62116 (Grid interconnection and anti-islanding), IEC / EN 62109 (Safety of power converters)Any other relevant BIS / IEC standards applicable at the time of installation.Warranty: Minimum 5 years warranty on the inverter |
| 28 | Battery Energy Storage System (BESS)Providing, supplying, installing, testing and commissioning of Lithium Iron Phosphate (LiFePO₄) Battery Energy Storage System of minimum 30 kWh integrated with 15 kW Hybrid Solar Inverter, complete with battery rack, interconnecting cables, protection devices, communication accessories, and monitoring system, as per approved drawings, manufacturer’s recommendations, and directions of Engineer-in-Charge.Battery Chemistry :Lithium Iron Phosphate (LiFePO₄), maintenance-free, deep cycle typeBattery Capacity & Configuration: Minimum 30 kWh total nominal energy capacity achieved by installing 02 (Two) Nos. LiFe PO₄ battery units of 16 kWh each Batteries shall be modular and scalable, suitable for parallel operationNominal Voltage & Operating Range : Nominal battery voltage around 51.2 V DC, Operating voltage range approximately 44.8 V – 57.6 V DCDepth of Discharge (DoD): Minimum 80–90% usable DoD, without affecting cycle lifeBattery Management System (BMS): Inbuilt advanced BMS with active protection for Over-charge, Over-discharge, Over-current, Short circuit, Over-temperature.Cycle Life : Minimum 6000 cycles at 25°C at recommended DoDEnclosure & Protection: Robust metal enclosure with minimum IP rating as per manufacturer catalog Suitable for indoor installation with adequate ventilation.......................................Cont............................ |
| 29 | Battery Rack & MountingBattery Rack : MS powder-coated / galvanized floor-mounted battery rack suitable for two (02) battery units Rack shall be corrosion-resistant, rigid, and capable of bearing full battery load with safety factorMounting Type : Floor-mounted / stack-mounted arrangement as per site conditions and manufacturer guidelinesWarranty : Minimum 5 years comprehensive warranty on batteries |
| 30 | EARTHINGSupply, Installation, Testing & Commissioning of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 25 mm dia. and l0 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm tested by CPRI capable of bearing fault current of 25 kA. Along with earth enhancement compound (jam plus) tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 50 kg ( 10 kg Bag x 5) resistivity is less than 0.12 ohm meter . The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement including cost of petty material required to complete the job in all respect. |
| 31 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 32 | DCDBSupplying, Installation, testing and commissioning of DC Distribution Box (DCDB) suitable for 30A solar DC input, comprising high-quality DC fuses, Type-II DC Surge Protection Device (SPD), suitably rated isolators (where required), internal copper busbars, and all interconnections. The DCDB shall be housed in an IP65/IP67 weatherproof, dustproof, termite-proof and UV-resistant outdoor enclosure,complete with cable glands, protection hardware and mounting accessories. |
| 33 | ESE TYPE LASupply, Installation, Testing & Commissioning of Lighting Arrestor which meets NFC 17-102 & UNE 21186 standards Tested to withstand multiple 40KA impulses High quality anti- corrosive and conductive coating Low wind resistance and light weight with accessories i.e. 25mm x 3mm GI Strip, GI Connector suitable for 330 Kwp Solar Power Plant etc. complete as reqd. |
| 34 | AC Distribution Board (ACDB)Providing, supplying, installing, testing and commissioning of AC Distribution Board (ACDB) suitable for grid-connected / hybrid solar power system, fabricated out of 1.6 mm thick CRCA sheet steel, dust and vermin proof, wall-mounted / floor-mounted type, powder-coated finish, complete with the following:Main Incomer: 4 Pole, 63 Amp, MCB, C-curve, 10 kA breaking capacity, conforming to IS/IEC 60898 / 60947, suitable for 415V, 50 Hz, complete with shrouds and phase identificationSurge Protection Device (SPD): Type-II Surge Protection Device, 3P+N configuration, suitable for 415V AC system, with visual indication and replaceable cartridge, conforming to IEC 61643, complete with internal MCB / fuse protection. |
| 35 | AC Isolator Switch : Providing, supplying, installing, testing and commissioning of AC Isolator Switch, suitable for three-phase, four-wire system, complete in all respects, as per details given below Isolator Rating : 4 Pole, 63 Amp, ON-LOAD Isolator, suitable for 415 V, 50 Hz AC supply, with positive break contacts, manual operation, and pad-lockable handle in OFF position.Enclosure: Fabricated out of minimum 1.6 mm thick CRCA sheet steel, dust and vermin proof. Wall-mounted / floor-mounted type, with hinged door Powder-coated finish, stove-enameled, with corrosion-resistant treatment Minimum IP-42 protection suitable for indoor installation |
| 36 | SH III:- Steel work |
| 37 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 38 | Hot finished welded type tubes |
| 39 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 40 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 41 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 meter openable length ( total length 90 m), having 50 nos. rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 42 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 43 | 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 44 | Finishing with Deluxe Multi surface paint system for interiors / exteriors as per manufacturers specifications: a) Painting Steel work with Deluxe Multi Surface Paint to give an even shade of approved brand and manufacture. |
| 45 | Sub Head-IV (E.I. Works) |
| 46 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. \\"GROUP C\\" |
| 47 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 48 | 3 x 1.5 sq. mm |
| 49 | 3 x 4 sq. mm |
| 50 | 6 x 4 sq. mm |
| 51 | 3 x 6 sq. mm |
| 52 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 53 | 20 mm |
| 54 | 25 mm |
| 55 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 56 | 5/6 A switch |
| 57 | 3 pin 5/6 A socket outlet |
| 58 | 15/16 A switch |
| 59 | 6 pin 15/16 A socket outlet |
| 60 | Bell push |
| 61 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 62 | 1 or 2 Module (75mmX75mm) |
| 63 | 3 Module (100mmX75mm) |
| 64 | 6 Module (200mmX75mm) |
| 65 | 12 Module (200mmX150mm) |
| 66 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 67 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 68 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 69 | 200 A,36KA,FPMCCB |
| 70 | 100 A,30KA,FPMCCB |
| 71 | 100 A, 16 KA,TPMCCB |
| 72 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 73 | 12 way , Double door |
| 74 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 75 | 12 way (4 + 36), Double door |
| 76 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB B complete with connections, testing and commissioning etc. as required. |
| 77 | Single pole |
| 78 | Single pole and neutral |
| 79 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 80 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% 53 DELHI SCHEDULE OF RATES (E&M)-2025 as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 81 | 100 watt WattLED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). |
| 82 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 83 | 18- 22 Watt (LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)) |
| 84 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator/remote for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 85 | 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 86 | Providing and fixing pole box of size 250mm X 200mm X 105mm with side openable hinged cover complete with two strip aluminium bus-bar of 100 amps capacity mounted on DMC bus support and 1 no. of SPMCB of 6 amps 'C' series capacity with din rail on the existing street light pole with the help of two nos. MS clamps of suitable size, including making hole to insert the cable and dismantling the worn out MS box etc. complete as required. |
| 87 | Supplying, installation, Testing & Commissioning of 36-40 Watt LED Panel light 4x1 ft., Surface/recess, CRCA powder-coated aluminum housing with LED driver as per the requirement Operating voltage AC 140-270 Volt, frequency 50/60 hz, life time of minimum 50000 Burning Hours with, CCT 3000°K / 4000°K / 5700°K /6500°K complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. |
| 88 | Supply, Installation of Single phase 250 mm Fresh Air Fan in the existing opening including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required |
| 89 | Fabrication, Supplying & installation of compartmentalised type Panel made of powder coated CRCA steel / galvanized steel sheet of 2 mm thick for framework & covers, 3 mm thick for gland plate duly compartmentalised of suitable size to accommodate incoming and outgoing MCCBs/MCBs having 1.5 times of incomer insulated TPN aluminium busbar, DMC/SMC bus bar supports, with locking arrangement, vermin-proof, weatherproof and mounted on the MS stand of MA angle 40x40x5 with grounting minimum 300 mm depth including connection, inter connection, earthing with 2 Nos. earth studs duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as required. (Depth should be 300 mm) |
| 90 | Supplying & Fixing of following electrical accessories in the existing cubical panel/Feeder pillar including connection, inter-connection etc. complete as required. |
| 91 | 3Ph LED Voltmeter Cl 0.5 accuracy Flush mounting 96 x 96 mm |
| 92 | 3Ph LED Ammeter Cl 0.5 accuracy Flush mounting 96 x 96 mm |
| 93 | LED Indication lamps (RYB) with selector switch (1 set of 3 nos.) |
| 94 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Armoured Copper power cable of 1.1 KV grade of following size in surface etc. as required. |
| 95 | 3.5 X 25 Sqmm |
| 96 | 3.5 X 50 Sqmm |
| 97 | Supplying, Installation, Testing and Commissioning of stainless steel storage type water cooler 150/150 Ltr. capacity, fully stainless steel suitable for operation on 230 V+10% 50 Hz single phase AC supply i/c making water line and electrical connection etc. as required. |
| 98 | Supplying, Installation, Testing and Commissioning of Reverse Osmosis (R.O. System) water Purification unit as per Technical specification attached i/c Providing suitable wall/floor mounting bracket, water connection from the available water inlet point with suitable C.P. angle valve and outlet upto the nearest drain with suitable PVC pipe, complete etc. as required.Purification Capacity – 50 Litres Per Hour ± 10%Technology - R.O + UV+alkalineMembranes - 4×80/100 GPDBooster pumps- 2X150 GPDInput water TDS - up to 2000-2500 PPM(Borewell/Tanker/Muncipal)Recovery Rate – 25% - 30%.Rejection Rate 90% - 95%. TDS ReductionAuto flushing - Built in Complete with Pre filtration with micron filter.20-inch PP Spun and Activated.Carbon 20 inch GAC/CTO etc. Complete as required. |
| 99 | Credit for old dismantle materials like Fitting, Cable, Fans, MCCB's, Gear Box, Rope Wire, switch and socket, pole box, Capacitor etc. |
| 100 | Associated Batten Fitting |
| 101 | Associated 1x4 fitting |
| 102 | Associated Fan |
| 103 | Associated Ventilation fan |
| 104 | Associated Cable |
| 105 | Associated Panel with MCCB |
| 106 | Associated Switch & socket |
| 107 | Associated Copper Wire |
| 108 | Associated Steel Conduit |
| 109 | Associated MS Box |
| 110 | Associated DB/TPDB |
| 111 | Associated Single Pole /DP Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail