| 1 | Demolishing R.C.C. work manually by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 3 | Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and cantilever upto floor two level complete in all respect with in all leads and lifts as per the direction and satisfaction of Engineer-in-Charge. |
| 4 | Edges of slabs and breaks in floors and walls under 20 Cm complete in all respect with in all leads and lifts as per the direction and satisfaction of Engineer-in-Charge. |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of entering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 7 | Dismentalling doors, windows and clearstory windows, ventilators etc. (wood or steel) shutters i/c chowkhats, architraves, hold fasta and other attachments etc. complete and stacking them with in 20 metres lead.(not exceeding 3 Sqm. in area) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 8 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required ngle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel elded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 9 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in- charge. (Note:- Butt hinges and necessary screws shall be paid.Second class teak wood 35 mm thick shutters complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 10 | Providing and fixing MS grills of required pattern in wooden frames of windows etc. with MS flats, square or rounded bars with round headed bolts and nuts or by screws complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 11 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 12 | 6 mm cement plaster to ceiling in cement mortar 1:3 (1 cement: 3 sand) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 13 | 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 14 | White washing with lime to give an even shade : New work (three or more coats) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 15 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 16 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 17 | Painting two coat Excluding priming coat on new wood and wood based. with ready mixed paint other than white complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 18 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. 300x16 mm |
| 19 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc.complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 20 | 250x10 mm |
| 21 | 150x10 mm |
| 22 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc.complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. 125mm. |
| 23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 24 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. Group C. |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 26 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 27 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 28 | Supplying and fixing following piano type switch/ socket on the existing switch 3 pin 5/6 Amps. Socket.complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 29 | Supplying and fixing following rating Piano- type switch /socket on the existing switch box / cover including connections etc.complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 30 | Supplying and fixing following rating Piano- type switch /socket on the existing switch box / cover including connections etc. as required.6 pin15/16 Amps. socket outlet complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 31 | Supplying and fixing following rating Piano- type switch /socket on the existing switch box / cover including connections etc.complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 32 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 33 | 180 mm.x 100 mm.x 60 mm. deep |
| 34 | 200 mm.x150 mm.x 60 mm. deep |
| 35 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 36 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 37 | Supplying and fixing 5 amps to 32 amps rating. 240/415 volts, 10 KA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Cat-A. (Single Pole) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 38 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) phosphatized and powder painted, including earthing etc. as required:- 8 way, Double door. complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 39 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (63 amp. CAT -A) |
| 40 | Providing, installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-.Ceiling fan 1400 mm sweep category complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. |
| 41 | Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required. 1 x28 watt-FTL(T5) (Category-A) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer-in-Charge. Please Enable Macros to View BoQ information |