| 1 | SUPPLY AND INSTALLATION OF 8 MTR MINI MAST SYSTEM |
| 2 | OD299869/2025-2026Supply installation testing and commissioning of High Mast using Octogaonal Polemade single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mmbottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable forwind speed as per IS 875 Part III with head frame assembly two point suspensionsystem with steel wire rope 5mm dia double drum winching system w and includinground arm galvanized luminary carriage suitable to install 6/8 nos luminaries insymmetrical arrangement control gear box and lighting spikes with single phaseoperation power tool installed inside the base compartment including connectorfoundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete8 Meters |
| 3 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Flood lightoutput greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surgeprotection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHScompliant, duly wired up for use on 230 V AC supply. Driver compartment should beseperatly accessible for maintenance (LM 79&80 certificates from NABL accreditedThird party lab to be produced mentioning chip manufacturer) |
| 4 | OD299868/2025-2026Feeder Pillar Sintex Double Door(56x24 cm),Including 25A 2 Pole AC 1 rated powercontactor, 25A Connector, Digital timer, Suitable Copper socket, 2.5 sq. mm ISImarked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISImarked FRLS PVC insulated single core copper conductor cable, OBO Bettermannmakes V25-B+ C/1+ NPE switching/lightning protection) for single-phase protection,HRC fuse base of 20/32A ,double pole, (single phase and neutral), 240 V, residualcurrent circuit breaker (RCCB),5 amps to 32 amps rating, 240/415 volts MCB Doublepole and single pole, Auto-Manual Selector Switch for Motor Control 2 way 2 pole. |
| 5 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU'section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 6 | 90.14.3.2 : Supply and providing heavy duty 'A' section neopren90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel boarde gasket in the panel board |
| 7 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 8 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm |
| 9 | 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 10 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 11 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 12 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 13 | 90.12.5.3Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 14 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 15 | 9.1.2Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.2 X 10 sq. mm (19mm) |
| 16 | OD299867/2025-2026Fabrication ,supply, conveyance and installation of Granite name board indicating thecost involved, the commencement, completion and inauguration date etc |
| 17 | CIVIL WORKS |
| 18 | 2.6.1 : Earth2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 19 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 20 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 21 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 22 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 23 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 24 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. Please Enable Macros to View BoQ information |