|
| 1 | Detailed Estimate |
| 2 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 3 | 26.28.2:Chipping of unsound/weak concrete material from slabs, beams, columns etc.with manual Chisel and/ or by standard power driven percussion type or ofapproved make including tapering of all edges, making square shoulders ofcavities including cleaning the exposed concrete surface and reinforcementwith wire brushes etc. and disposal of debris for all lead and lifts all completeas per direction of Engineer-In-Charge50mm average thickness |
| 4 | 26.29.1:Cleaning of reinforcement from rust from the reinforcing bars to give it a totalrust free steel surface by using alkaline chemical rust remover of approvedmake with paint brush and removing loose particles after 24 hours of itsapplication with wire brush and thoroughly washing with water and allowingit to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter |
| 5 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 7 | 26.31.1:Providing, mixing and applying bonding coat of approved adhesive on chippedportion of RCC as per specifications and direction of Engineer-In-chargecomplete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 8 | 50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 9 | 22.7.1:Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in Charge:With average thickness of 120 mm and minimum thickness at khurra as 65 mm |
| 10 | 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 11 | 11.55.1: Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 12 | 11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm. |
| 13 | OD242812/2023-2024:Engaging coolie for cleaning drainage lines ,terrace and sunshade and cleaning & removing waste materials from the compound |
| 14 | OD235770/2023-2024:Engaging coolies for clearing and removing plants from roof top |
| 15 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 16 | OD327374/2025-2026:Finishing with epoxy paint(two or more coats) at all locations prepared and applied as per manufacturer's specifications, excluding priming coat, preparation of surface, etc, complete.On steel work |
| 17 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 18 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 19 | 15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix) |
| 20 | 16.77:Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material within all lifts and lead upto 1 km ( by mechanical means). |
| 21 | OD320724/2025-2026:Developing of existing tubewell as per G.O(P.) No.44/2018/FIN, dated 17.03.2018 |
| 22 | OD312226/2025-2026:Charges for lifting 7.50/10/12.50/15 HP submersible pump set from the tube well after disconnecting all cables, seperating the delivery pipes and valves from the vertical column pipes cutting the MS flats welded across the joints, lifting the column pipe one by one, stacking in the convenient place per the direction, decoupling the pump and motor, dismantling the pump set and detecting the fault, resetting back etc. complete. |
| 23 | OD312225/2025-2026:Charges for erecting the 7.50/10/12.50 HP pump set in to the tube well after coupling pump and motor including erecting three column pipes one by one, welding MS flats across the joints, coupling the delivery pipes and valves to the vertical column pipes, connecting motor to starter after connecting all wires and cables etc |
| 24 | OD312224/2025-2026:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846-2000, Sluice Valve with Hand Wheel PN 1.6, Size 100 mm |
| 25 | 18.19.6.1:Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreHorizontal |
| 26 | 18.19.6.2:Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreVertical |
| 27 | 18.31.1.1:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass I |
| 28 | OD248613/2023-2024:Providing and fixing UPVC pipes including jointing of pipes with one step UPVC solvent cement ,trenching,refilling and testing of joints complete as per direction of Engineer -in-charge 75mm dia 6kgf/cm2 |
| 29 | OD248614/2023-2024:providing and fixing UPVC pipes including fixing the pipe with clamps / clips at 1.00m spacing. This included jointing of pipes with one step UPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge 75mm dia 6kgf/cm2 External work-Exposed on wall |
| 30 | OD248615/2023-2024:Providing and fixing UPVC pipes including jointing of pipes with one step UPVC solvent cement ,trenching,refilling and testing of joints complete as per direction of engineer in charge 110mm dia 6kg f/cm2 |
| 31 | OD248616/2023-2024:Providing and fixing UPVC pipes including fixing the pipe with clamps/clips/at 1.00m spacing.This includes jointing of pipes with one step UPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge 110mm dia 6kgf/cm2-External work- Exposed on wall |
| 32 | OD248617/2023-2024:Providing and fixing UPVC moulded fittings / accessories for Rigid UPVC pipes , including jointing with UPVC solvent cement -110mm dia Elbow |
| 33 | OD248618/2023-2024:Providing and fixing UPVC moulded fittings/accessories for Rigid UPVC pipes, including, jointing with UPVC solvent cement -110mm dia 45 degree Elbow |
| 34 | OD248621/2023-2024:UPVC MTA 110mm dia |
| 35 | OD248622/2023-2024:Providing and fixing UPVC gate valve 110mm dia |
| 36 | OD248623/2023-2024:Providing and fixing UPVC moulded fitting / accessories for Rigid UPVC pipes, including jointing with UPVC solvent cement 110mm dia socket / coupling |
| 37 | OD248625/2023-2024:Providing and fixing UPVC moulded fittings/ accessories for Rigid UPVC pipes,including jointing with UPVC solvent cement -110x75mm dia |
| 38 | OD248626/2023-2024:providing and fixing CPVC moulded fittings/ accessories for Rigid CPVC pipes, including jointing with CPVC solvent cement 110x75mm dia Reducer |
| 39 | OD248630/2023-2024:Providing and fixing UPVC moulded fittings/accessories for Rigid UPVC pipes including jointing with UPVC solvent cement 110*110*110 mm dia Tee |
| 40 | OD248745/2023-2024:CPVC MTA 110mm dia |
| 41 | OD248747/2023-2024:UPVC FTA 110mm dia |
| 42 | OD248748/2023-2024:Providing and fixing CPVC moulded fittings/accessories for Rigid CPVC pipes including jointing with CPVC solvent cement 110x110x110mm dia Tee |
| 43 | OD248750/2023-2024:CPVC bush 110x75mm dia |
| 44 | OD248751/2023-2024:Providing and fixing CPVC moulded fittings / accessories for Rigid CPVC pipes,including,jointing with CPVC solvent cement -110mm dia 45 degree elbow |
| 45 | OD248752/2023-2024:Providing and fixing UPVC moulded fittings/accessories for Rigid UPVC pipes,including jointing with UPVC solvent cement -75mm dia Elbow |
| 46 | OD248754/2023-2024:Providing and fixing UPVC moulded fittings/accessories for Rigid UPVC pipes,including,jointing with UPVC solvent cement -75mm dia 45 degree Elbow |
| 47 | OD248755/2023-2024:UPVC MTA 75mm dia |
| 48 | OD248756/2023-2024:Providing and fixing UPVC gate valve 75mm dia |
| 49 | OD248757/2023-2024:Providing and fixing UPVC gate valve 63mm dia |
| 50 | OD248759/2023-2024:UPVC MTA 63mm dia |
| 51 | OD248795/2023-2024:63mm dia G.I Tee |
| 52 | OD248796/2023-2024:Providing and fixing UPVC moulded fittings/accessories for Rigid UPVC pipes,including jointing with UPVC solvent cement 75x63mm dia Reducer |
| 53 | OD249010/2023-2024:Engaging plumber for dismantling existing plumbing lines,repairing sanitary fittings and water lines as per the direction of Engineer in charge |
| 54 | 18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore |
| 55 | 50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 56 | 50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 57 | 50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend |
| 58 | 50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 59 | 50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer |
| 60 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 61 | 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee Please Enable Macros to View BoQ information |