| 1 | Supplying of 70 W LED Street Light with IP 66 protection and minimum efficacy of 110 lumens/watt. Make: Crompton, Model: TRP-421-70-57-SL-LM-NBK or equivalent. |
| 2 | Erection of Street light including connection, testing and commissioning etc. as required. |
| 3 | Fabrication and erection of metallic street light pole made out of G.I.pipes (80mm & 40mm) dia), G.I reducer, M.S base plate (250mmx 250mmx 6mm) etc. suitable for fixing 01 no. Street light fitting including cutting, bending, drilling, welding, painting with one coat of metallic primer & 2 coats of synthetic enamel paint etc as required and making pedestal (400 x 400 x 800mm) above ground with 1:3:6 cement concrete, shuttering, plastering the finished pedestal with 1:4 (1 cement and 4 coarse sand) and painting with two coats of exterior weather shield paint etc as per the direction of Engineer-in-charge. |
| 4 | Supplying and fixing weather proof Sintex box of size 140x140x95 mm (inside dimensions), code. No. GS-JB 1414 on the existing wall surface with suitable clamping arrangement including providing and fixing following mountings etc. as required. a) Din Channelb) 6A, SPMCB - 01 No.c) 30A, 230V, 4 way bakelite connector- 1 No. |
| 5 | Supplying of following sizes XLPE insulated and PVC sheathed heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to IS: 7098 (Part I) 1988 as applicable. Make : Polycab or equivalent. |
| 6 | 2 core core x 6 Sq.mm |
| 7 | 3 core core x 6 Sq.mm |
| 8 | 4 core core x 6 Sq.mm |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205 (Part 24) complete with fitting and cutting, jointing on surface/wall including clamping etc as required. Make: Prince or equivalent. |
| 10 | 40 mm outer dia nominal size |
| 11 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205 (Part 24) complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. Make: Prince or equivalent. |
| 12 | 40 mm outer dia nominal size |
| 13 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205 (Part 24) complete with fitting and cutting, jointing etc.direct in ground (10 cm below ground level) including cutting the hard rock and refilling the same by cement concrete 1:2:4 after laying pipe and ramming the soil etc as required. Make: Prince or equivalent. |
| 14 | 40 mm outer dia nominal size |
| 15 | Supplying and laying of following dia G.I pipe (medium class) direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 16 | 65 mm dia |
| 17 | Supplying and laying of following dia G.I pipe (medium class) across the road including cutting the hard rock/PCC upto the depth of 10 cm and refilling the same by cement concrete 1:2:4 after laying pipe and ramming the soil etc as required. |
| 18 | 65 mm dia |
| 19 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing DWC/ METAL pipe as required. |
| 20 | Upto 35 sq. mm |
| 21 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface as required. |
| 22 | Upto 35 sq. mm |
| 23 | Supplying, Installation, testing and commissioning of ASHLOK make SEE brand safe earthing electrode type 19, 48 mm dia, length 2 mtrs and inner space to be filled with crystaline conductive mixture including filling-up with electrodite (Back fill Compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc.as required. |
| 24 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 25 | Fabrication, Installation, Testing and Commissioning of out door type 1 phase Street light Panel of minimum size 0.9 x 0.8 x 0.35 M with 4 legs of 0.6 mtr, made out of MS angle (30x30x3mm & 25x25x3mm), MS flat (25x3mm), and 16 SWG plain G.I sheet having plain roof, double leaf type hinged door at front, locking arrangement, dust poof, vermin poof and proper space to accomodate Energy meter, following rating Switch gears and acceessories and grouting the feeder pillar on suitable size concrete pedestal made of 1:3:6 cement concrete including inter connection etc. as directed by Engineer in Charge.a) 32 A Porcelain Fuse Carrier / Cutout, Make: Anchor or equivalent - 01 No.b) 40 A DP MCB (10 kA), Make: L&T or equivalent - 01 No.c) Digital Timer (230 V AC, 16 A), Make: Selec Time Switch, Code: TS2M1 or equivalent - 01 No.d) 2 Pole Power Contactor, Make: L&T, Type: MNX 25 or equivalent - 01 No. e) Manual–Auto Selector Switch (2-position), 25 A, Make: L&T or equivalent - 01 No. f) 6 A SP MCB (10 ka), Make: L&T or equivalent - 01 No.g) 25 A SP MCB (10 ka), Make: L&T or equivalent - 01 No.h) LED type Indicator Lamps, R (Power ON), G (Load ON), Y (Timer ON), Make: L&T or equivalent - 03 Nos.i) Other electrical accessories like Insulator, Nuts & bolts, Earth stud, Din Channel, PVC Cable Ducts, Terminal Block, End plate, End clamp, interconnection cable etc - 01 Set. |
| 26 | Fabrication, Installation, Testing and Commissioning of out door type 1 phase Street light Panel of minimum size 0.9 x 0.8 x 0.35 M with 4 legs of 0.6 mtr, made out of MS angle (30x30x3mm & 25x25x3mm), MS flat (25x3mm), and 16 SWG plain G.I sheet having plain roof, double leaf type hinged door at front, locking arrangement, dust poof, vermin poof and proper space to accomodate Energy meter, following rating Switch gears and acceessories and grouting the feeder pillar on suitable size concrete pedestal made of 1:3:6 cement concrete including inter connection etc. as directed by Engineer in Charge.a) 32 A Porcelain Fuse Carrier / Cutout, Make: Anchor or equivalent - 01 No.b) 40 A FP MCB (10 kA), Make: L&T or equivalent - 01 No.c) Digital Timer (230 V AC, 16 A), Make: Selec Time Switch, Code: TS2M1 or equivalent - 01 No.d) 3 Pole Power Contactor, Make: L&T, Type: MNX 25 or equivalent - 01 No. e) Manual–Auto Selector Switch (2-position), 25 A, Make: L&T or equivalent - 01 No. f) 6 A SP MCB (10 ka), Make: L&T or equivalent - 01 No.g) 25 A SP MCB (10 ka), Make: L&T or equivalent - 01 No.h) LED type Indicator Lamps, R (Power ON), G (Load ON), Y (Timer ON), Make: L&T or equivalent - 03 Nos.i) LED type Phase Indication Lamps (R-Y-B) - 03 Nos.j) Other electrical accessories like Insulator, Nuts & bolts, Earth stud, Din Channel, PVC Cable Ducts, Terminal Block, End plate, End clamp, interconnection cable etc - 01 Set. |
| 27 | Dismantling/demolishing of existing street light pole with removal of PCC pedestal and associated fittings as required, including disposal of debris as directed by the Engineer-in-Charge. |
| 28 | Painting of existing street light pole with two coats of synthetic enamel paint and PCC Pedestal with exterior weather shield paint including cleaning the surface with detergent, removing dust and rust, and preparing the surface as required, complete in all respects as directed by the Engineer-in-Charge. |
| 29 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 30 | 3 x 1.5 sq. mm Please Enable Macros to View BoQ information |